Upper cervical spine movement during intubation with different airway devices

被引:7
|
作者
Kilic, Taylan [1 ]
Goksu, Erkan [1 ]
Durmaz, Dilek [1 ]
Yildiz, Gunay [1 ]
机构
[1] Akdeniz Univ, Sch Med, Dept Emergency Med, TR-07058 Antalya, Turkey
来源
AMERICAN JOURNAL OF EMERGENCY MEDICINE | 2013年 / 31卷 / 07期
关键词
IN-LINE STABILIZATION; MCCOY LARYNGOSCOPE; CADAVER MODEL; OROTRACHEAL INTUBATION; MACINTOSH LARYNGOSCOPE; MOTION; MANAGEMENT; VERTEBRAE; BULLARD; BLADE;
D O I
10.1016/j.ajem.2013.03.029
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Prevention of secondary neurologic injury is critical during the airway management of a trauma patient. Trauma patients are assumed to have an unstable cervical spine (C-spine) until proven otherwise: orotracheal intubation during airway management may result in a certain amount of C-spine movement. This study, therefore, aimed to compare C-spine movement within different advanced airway devices (Macintosh blade, McCoy Blade, LMA, I-LMA, and Combitube) during airway management. Materials and Methods: A total of 3 fresh frozen cadavers were used. The cadavers were consecutively intubated by 4 different postgraduate year residents with LMA4, I-LMA5, Combitube (37F), Macintosh 3, and McCoy blades. The cinefluoroscopic view of the entire intubation process was recorded, and vertebral body angles were calculated. Results: At the C0C1 level, compared with the McCoy laryngoscope (median, 7 degrees), the LMA (median, 2.5 degrees) and the Combitube (median, 1.5 degrees) caused less extension of the cervical vertebra. In addition, the Combitube (median, -1 degrees) and the I-LMA (median, -2 degrees) caused less extension of the C2C3 region when compared with the Macintosh laryngoscope (median, 3 degrees). There was no significant difference between groups at the C1C2, C3C4, and C4C5 segments. Conclusion: Supraglottic devices used during airway management cause C-spine movement less or equal to conventional laryngoscopes. Furthermore, because of ease of training and blind insertion, supraglottic devices can be safely used with trauma patients when C-spine integrity is a concern. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1034 / 1036
页数:3
相关论文
共 50 条
  • [1] Upper cervical spine movement during intubation: fluoroscopic comparison of the AirWay Scope, McCoy laryngoscope, and Macintosh laryngoscope
    Maruyama, K.
    Yamada, T.
    Kawakami, R.
    Kamata, T.
    Yokochi, M.
    Hara, K.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (01) : 120 - 124
  • [2] CERVICAL-SPINE MOVEMENT DURING OROTRACHEAL INTUBATION
    MAJERNICK, TG
    BIENIEK, R
    HOUSTON, JB
    HUGHES, HG
    ANNALS OF EMERGENCY MEDICINE, 1986, 15 (04) : 417 - 420
  • [3] Approach Combining the Airway Scope and the Bougie for Minimizing Movement of the Cervical Spine during Endotracheal Intubation
    Takenaka, Ichiro
    Aoyama, Kazuyoshi
    Iwagaki, Tamao
    Ishimura, Hiroshi
    Takenaka, Yukari
    Kadoya, Tatsuo
    ANESTHESIOLOGY, 2009, 110 (06) : 1335 - 1340
  • [4] Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope
    Rudolph, C
    Schneider, JP
    Wallenborn, J
    Schaffranietz, L
    ANAESTHESIA, 2005, 60 (07) : 668 - 672
  • [5] Complete upper airway obstruction during awake fibreoptic intubation in patients with unstable cervical spine fractures
    Glenn McGuire
    Hossam El-Beheiry
    Canadian Journal of Anesthesia, 1999, 46 : 176 - 178
  • [6] Complete upper airway obstruction during awake fibreoptic intubation in patients with unstable cervical spine fractures
    McGuire, G
    El-Beheiry, H
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (02): : 176 - 178
  • [7] COMPARISON OF FOUR ENDOTRACHEAL INTUBATION DEVICES ON CERVICAL SPINE MOVEMENT IN A CADAVER MODEL
    Romito, Jia
    Minhajuddin, Abu
    Bagley, Carlos
    McDonagh, David
    CRITICAL CARE MEDICINE, 2018, 46 (01) : 769 - 769
  • [8] Cervical spine movement during intubation using the Airtraq® and direct laryngoscopy
    Erden, I. Aydin
    Pamuk, A. Guelsuen
    Uzun, Sennur
    Geyik, Serdar
    Cekirge, Saruhan
    Aypar, Uelkue
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2010, 40 (02) : 299 - 304
  • [9] Cadaveric study of movement in the unstable upper cervical spine during emergency management: tracheal intubation and cervical spine immobilisation - a study protocol for a prospective randomised crossover trial
    Liao, Shiyao
    Popp, Erik
    Huettlin, Petra
    Weilbacher, Frank
    Muenzberg, Matthias
    Schneider, Niko
    Kreinest, Michael
    BMJ OPEN, 2017, 7 (08):
  • [10] Cervical spine movement using the Airway Scope
    McClelland, S. H.
    McCahon, R. A.
    Norris, A. M.
    ANAESTHESIA, 2008, 63 (02) : 207 - 208