Improving spinach quality and reducing energy costs by retrofitting retail open refrigerated cases with doors

被引:26
|
作者
de Frias, J. Atilio [1 ,2 ]
Luo, Yaguang [1 ]
Kou, Liping [3 ]
Zhou, Bin [1 ]
Wang, Qin [2 ]
机构
[1] ARS, USDA, Beltsville Agr Res Ctr, Food Qual Lab, Beltsville, MD 20705 USA
[2] Univ Maryland, Dept Nutr & Food Sci, College Pk, MD 20742 USA
[3] Northwest A&F Univ, Coll Food Sci & Engn, Yangling 712100, Shaanxi, Peoples R China
关键词
Open refrigerated display cases; Display cases with doors; Baby spinach quality; Energy savings; ESCHERICHIA-COLI O157H7; TEMPERATURE; DISPLAY; COMBINATION; STORAGE;
D O I
10.1016/j.postharvbio.2015.06.016
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
The prevalence of open-refrigerated display cases is ubiquitous in retail supermarkets, even in the face of the non-uniform temperature conditions present in these cases. In this paper, the temperature variations (Delta T) of packaged ready-to-eat baby spinach were evaluated for an open display case and a display case with glass doors, in order to assess the advantages of this physical barrier in minimizing Delta T and decay rate, and improving the visual quality of the samples after four days of storage. The two 3.66 m display cases were installed in the same room and conditions were constant at 21 degrees C and 60-70% of relative humidity, with a thermostat setting for both cases set at 0.6 degrees C. Results showed that the display case with doors significantly improved temperature uniformity and compliance with the U.S. Food and Drug Administration (FDA) Food Code recommendation of 5 degrees C or less to prevent microbial pathogen growth in packaged leafy greens. Only 1% of the temperature readings over four days in the case with doors were non-compliant with the FDA Food Code, while 24% of the readings in the open case were non-compliant; mostly recorded by the front positions of the case. The lower temperatures and Delta T of the case with doors were consistent with the higher visual quality scores (P < 0.001) for the baby spinach samples recorded by trained panelists, based on a 9-point hedonic scale, at 7.2 and 6.6 for the case with doors and the open case, respectively. Differences in decay rate were significant (P < 0.001) by the front of the case, with mean values of 8.8% for the open case and 5.5% for the case with doors. Furthermore, operational energy costs were 69% less than the open display case and the cost of door retrofits can be recouped in less than two years by energy savings alone. Published by Elsevier B.V.
引用
收藏
页码:114 / 120
页数:7
相关论文
共 50 条
  • [1] Minimizing quality deterioration of fresh-cut baby spinach by retrofitting refrigerated retail display cases with doors
    Xie, Y.
    Brecht, J. K.
    Abrahan, C.
    Luo, Y.
    Bornhorst, E.
    IV INTERNATIONAL CONFERENCE ON FRESH-CUT PRODUCE: MAINTAINING QUALITY AND SAFETY, 2021, 1319 : 59 - 66
  • [2] Improving temperature management and retaining quality of fresh-cut leafy greens by retrofitting open refrigerated retail display cases with doors
    Xie, Yurui
    Brecht, Jeffrey K.
    Abrahan, Carolina E.
    Bornhorst, Ellen R.
    Luo, Yaguang
    Monge, Ana Lorena
    Vorst, Keith
    Brown, Wyatt
    JOURNAL OF FOOD ENGINEERING, 2021, 292
  • [3] Open-refrigerated retail display case temperature profile and its impact on product quality and microbiota of stored baby spinach
    Kou, Liping
    Luo, Yaguang
    Ingram, David T.
    Yan, Shoulei
    Jurick, Wayne M., II
    FOOD CONTROL, 2015, 47 : 686 - 692
  • [4] REDUCING COSTS OF QUALITY AND IMPROVING PROCESSES: A CASE STUDY
    Oliveira, Gabriel Rech
    Ventura da Motta, Marta Elisete
    Camargo, Maria Emilia
    Goncalves Tondolo, Vilmar Antonio
    Zanandrea, Gabriela
    Russo, Suzana Leitao
    REVISTA GEINTEC-GESTAO INOVACAO E TECNOLOGIAS, 2016, 6 (02): : 3241 - 3256
  • [5] REDUCING ENERGY AND MAINTENANCE COSTS WHILE IMPROVING LIGHT QUALITY AND RELIABILITY WITH LED LIGHTING TECHNOLOGY
    Schratz, Michael
    Gupta, Christine
    Struhs, T. J.
    Gray, Kara
    CONFERENCE RECORD OF 2013 ANNUAL IEEE PULP AND PAPER INDUSTRY TECHNICAL CONFERENCE (PPIC), 2013,
  • [6] Retrofitting for Improving Indoor Air Quality and Energy Efficiency in the Hospital Building
    Radha, Chro Hama
    SUSTAINABILITY, 2023, 15 (04)
  • [7] Ductile iron melting trends: Reducing costs, improving quality
    Csonka, J.
    Woods, J.
    Muratore, E.
    Modern Casting, 2002, 92 (05)
  • [8] Reducing costs and improving quality by systematically improving process flows together with the ICU team
    Marsolek, I
    Friesdorf, W
    INTENSIVE CARE MEDICINE, 2001, 27 : S209 - S209