Integrated humidity sensor based on SU-8 polymer microdisk microresonator

被引:64
|
作者
Eryurek, M. [1 ]
Tasdemir, Z. [4 ]
Karadag, Y. [2 ]
Anand, S. [1 ]
Kilinc, N. [3 ]
Alaca, B. E. [4 ,5 ]
Kiraz, A. [1 ,6 ]
机构
[1] Koc Univ, Dept Phys, TR-34450 Istanbul, Turkey
[2] Marmara Univ, Dept Phys, TR-34722 Istanbul, Turkey
[3] Nigde Univ, Mechatron Engn Dept, TR-51245 Nigde, Turkey
[4] Koc Univ, Dept Mech Engn, TR-34450 Istanbul, Turkey
[5] Koc Univ, Surface Sci & Technol Ctr, TR-34450 Istanbul, Turkey
[6] Koc Univ, Dept Elect & Elect Engn, TR-34450 Istanbul, Turkey
关键词
Microdisk; Whispering gallery mode; SU-8; FEM; humidity sensor; microresonator; FABRICATION;
D O I
10.1016/j.snb.2016.09.136
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Due to its high interaction with water vapor and photolithographic patterning property, SU-8 is a favorable hygroscopic polymer for developing humidity sensors. In addition, optical resonances of optical microresonators are very sensitive to the dianges in their environment. Here, we present integrated optical humidity sensors based on chips containing SU-8 polymer microdisks and waveguides fabricated by single-step UV photolithography. The performance of these sensors is tested under a wide range of relative humidity (RH) levels (0-50%). A tunable laser light is coupled from an excitation fiber to individual SU-8 waveguides using end-face coupling method. As the laser wavelength is scanned, the whispering gallery modes (WGMs) are revealed as dips in the transmission spectra. Sensing is achieved by recording spectral shifts of the WGMs of the microdisk microresonators. Red shift is observed in the WGMs with increasing RH. Between 0 and 1% RH, an average spectral shift sensitivity of 108 pm/% RH is demonstrated from measurements performed on 4 sensor devices. This sensitivity is comparable to the highest values obtained using microresonators in the literature. Measurements performed with another sensor device revealed a decrease in sensitivity by only around 3 times when RH is increased to 45-50%. Finite element modeling simulations are carried out to determine the dominant effect responsible for the resonance shift. The results show that the refractive index change is more important than the microresonator size change. The standard deviation in wavelength measurement is <3 pm, indicating a limit of detection better than 0.03% RH. These results suggest that optical sensor devices that contain integrated SU-8 microresonators and waveguides can be employed as easy-to-fabricate and sensitive humidity sensors. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1115 / 1120
页数:6
相关论文
共 50 条
  • [1] A micro pressure sensor based on SU-8 polymer
    Zheng, Xiaohu
    Han, Chang-Yong
    [J]. ADVANCES IN MANUFACTURING TECHNOLOGY, PTS 1-4, 2012, 220-223 : 1902 - 1905
  • [2] SU-8 cantilever strain sensor with integrated readout based on a piezoresistive SU-8/carbon black composite
    Gammelgaard, L
    Rasmussen, P
    Calleja, M
    Boisen, A
    [J]. Micro Total Analysis Systems 2004, Vol 2, 2005, (297): : 482 - 484
  • [3] A Micro Pressure Sensor with SU-8 Polymer
    Zhu, Xiaohong
    Yin, Yonghua
    Zheng, Xiaohu
    [J]. PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON APPLIED MECHANICS, MECHATRONICS AND INTELLIGENT SYSTEMS (AMMIS2015), 2016, : 299 - 304
  • [4] Integrated Lossy Mode Resonance Sensor Based on SU-8 Waveguides
    Letko, Edvins
    Bundulis, Arturs
    Mozolevskis, Gatis
    Vibornijs, Viktors
    [J]. ORGANIC PHOTONIC MATERIALS AND DEVICES XXIV, 2022, 11998
  • [5] SU-8 cantilever sensor system with integrated readout
    Johansson, A
    Calleja, M
    Rasmussen, PA
    Boisen, A
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2005, 123-24 : 111 - 115
  • [6] Humidity influence on the adhesion of SU-8 polymer from MEMS applications
    Birleanu, Corina
    Pustan, Marius
    Voicu, Rodica
    Serdean, Florina
    Merie, Violeta
    [J]. MODERN TECHNOLOGIES IN MANUFACTURING (MTEM 2017 - AMATUC), 2017, 137
  • [7] Su-8 based piezoresistive mechanical sensor
    Thaysen, J
    Yalçinkaya, AD
    Vestergaard, RK
    Jensen, S
    Mortensen, MW
    Vettiger, P
    Menon, A
    [J]. FIFTEENTH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2002, : 320 - 323
  • [8] Thermal UV treatment on SU-8 polymer for integrated optics
    Wang, Xi-Bin
    Sun, Jian
    Chen, Chang-Ming
    Sun, Xiao-Qiang
    Wang, Fei
    Zhang, Da-Ming
    [J]. OPTICAL MATERIALS EXPRESS, 2014, 4 (03): : 509 - 517
  • [9] SU-8 cantilever sensor with integrated read-out
    Johansson, A
    Calleja, M
    Rasmussen, P
    Marie, R
    Boisen, A
    [J]. Micro Total Analysis Systems 2004, Vol 2, 2005, (297): : 488 - 490
  • [10] Fluorine plasma treatment on SU-8 polymer for integrated optics
    Bêche, B
    Papet, P
    Debarnot, D
    Gaviot, E
    Zyss, J
    Poncin-Epaillard, F
    [J]. OPTICS COMMUNICATIONS, 2005, 246 (1-3) : 25 - 28