A Monte Carlo model for independent dose verification in serial tomotherapy

被引:0
|
作者
Sarkar, Vikren [1 ]
Stathakis, Sotirios [1 ]
Papanikolaou, Nikos [1 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Canc Therapy & Res Ctr, San Antonio, TX 78229 USA
关键词
IMRT; dose verification; Monte Carlo; serial tomotherapy;
D O I
10.1177/153303460800700506
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Due to the very high complexity of IMRT treatment plans, it is imperative to perform dose verification, preferably before patient delivery. The aim of this project is to develop a Monte-Carlo-based model to verify the final dose distributions of plans developed using the Peacock system (CORVUS Treatment Planning System and MIMIC collimator). The system delivers radiation through arc therapy and uses sinogram files to determine the state of each of the multileaf collimator leaves. In-house software was developed using Matlab to decode the sinograms and create blocklets that are used as input in an MCSIM model of the MIMIC collimator attached to a Varian Clinac 600C. After validating the model, a prostate and head and neck case were simulated. The CORVUS-predicted dose distributions were compared with the Monte Carlo dose distributions. As expected, the results agreed very closely for the homogeneous case of the prostate but there were large discrepancies observed for the more heterogeneous head and neck case.
引用
收藏
页码:385 / 391
页数:7
相关论文
共 50 条
  • [1] The Use of Monte Carlo Method as An Independent Dose Verification Calculation Tool for TomoTherapy
    Chen, Q.
    Ding, K.
    Levinson, L.
    Read, P.
    Benedict, S.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3709 - 3709
  • [2] Monte Carlo based dose verification for serial tornotherapy
    Stathakis, S.
    Sarkar, V.
    Rassiah-Szegedi, P.
    Mavroidis, P.
    Papanikolaou, N.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2470 - 2470
  • [3] Effective clinical applications of Monte Carlo-based independent secondary dose verification software for helical tomotherapy
    Kosaka, Takahiro
    Takatsu, Jun
    Inoue, Tatsuya
    Hara, Naoya
    Mitsuhashi, Taira
    Suzuki, Michimasa
    Shikama, Naoto
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 104 : 112 - 122
  • [4] Dosimetric evaluation in Helical TomoTherapy for lung SBRT using Monte Carlo-based independent dose verification software
    Kosaka, Takahiro
    Takatsu, Jun
    Inoue, Tatsuya
    Iijima, Kotaro
    Suzuki, Michimasa
    Murakami, Naoya
    Shikama, Naoto
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (05):
  • [5] Monte Carlo calculation of helical tomotherapy dose delivery
    Zhao, Ying-Li
    Mackenzie, M.
    Kirkby, C.
    Fallone, B. G.
    [J]. MEDICAL PHYSICS, 2008, 35 (08) : 3491 - 3500
  • [6] Monte Carlo-based independent dose verification of radiosurgery HyperArc plans
    Calvo-Ortega, Juan-Francisco
    Moragues-Femenia, Sandra
    Laosa-Bello, Coral
    Hermida-Lopez, Marcelino
    Pozo-Masso, Miguel
    Zamora-Perez, Antonia
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 102 : 19 - 26
  • [7] MONTE CARLO DOSE CORRECTION FACTORS DETERMINATION FOR TOMOTHERAPY BEAM
    Stravato, A.
    Rauco, R.
    Aragno, D.
    Pacilio, M.
    Pressello, M. C.
    Santini, E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S518 - S519
  • [8] Monte Carlo Dose Calculation for TomoTherapy Using Cloud Computing
    Chen, Q.
    Humphrey, M.
    Ding, K.
    Sterpin, E.
    Read, P.
    Larner, J.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [9] Monte Carlo Generation of Phase Spaces for Dose Computation in TomoTherapy
    Moreau, M.
    Chen, Y.
    Cravens, B.
    Mauer, C.
    Sterpin, E.
    Salvat, F.
    Ruchala, K.
    Olivera, G.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2799 - +
  • [10] A Clarkson-Based Independent Dose Verification for the Helical Tomotherapy
    Nagata, H.
    Hongo, H.
    Kawai, D.
    Takahashi, R.
    Hashimoto, H.
    Tachibana, H.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3524 - 3524