Dynamic Contrast-enhanced CT of Head and Neck Tumors: Comparison of First-pass and Permeability Perfusion Measurements Using Two Different Commercially Available Tracer Kinetics Models

被引:22
|
作者
Bisclas, Sotirios [1 ,2 ]
Konstantinou, Giorgos [3 ]
Surlan-Popovic, Katarina [4 ]
Khoshneviszadeh, Arjang [1 ,2 ]
Baghi, Mehran
Vogl, Thomas J. [1 ,2 ]
Koh, Tong San [5 ]
Mack, Martin G. [1 ,2 ]
机构
[1] Johann Wolfgang Goethe Univ Hosp, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Johann Wolfgang Goethe Univ Hosp, Dept Otorhinolaryngol, D-60590 Frankfurt, Germany
[3] 401 Gen Mil Hosp, Athens, Greece
[4] Clin Ctr Ljubljana, Dept Clin Radiol, Ljubljana, Slovenia
[5] Nanyang Technol Univ, Ctr Modeling & Control Complex Syst, Singapore, Singapore
关键词
Head and neck cancer; perfusion CT; distributed-parameter analysis; deconvolution-based analysis; maximum slope model; Patlak analysis;
D O I
10.1016/j.acra.2008.05.021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To evaluate the interchangeability of perfusion parameters between two software packages for the postprocessing of dynamic contrast-enhanced (DCE) computed tomographic images of head and neck tumors. Materials and Methods. DCE computed tomographic images of 75 patients with head and neck tumors were postprocessed using a software package based on the maximum-slope approach and Patlak analysis, as well as a software package with deconvolution-based analysis incorporating an adiabatic approximation of tissue homogeneity (ATH) model. The evaluated perfusion parameters included blood flow (F), blood volume (v), and permeability-surface area product (PS). Region-of-interest (ROI) analysis of the tumors and the metastatic lymph nodes was performed. The perfusion parameters were compared using the Wilcoxon matched-pairs test and Bland-Altman plots. Results. One hundred fifty-two ROIs of tumors and nodes were outlined and analyzed. Moderate to good correlations were demonstrated between the various perfusion values (r = 0.56-0.72, P <.0001). The Wilcoxon test revealed a significant differencc between the two methods (P <.001), with the F, v, and PS values obtained using the maximum-slope approach and Patlak analysis higher than those obtained using deconvolution-based analysis with the assumptions of the ATH model. The Bland-Altman plots for F and v values revealed a proportionality trend with outliers, which were strongly associated with the magnitudes of the parameters. Analysis of the PS values did not show any systematic bias. Conclusion. There were significant differences in the perfusion parameters obtained using the two software packages, and thus, these parameters are not directly interchangeable.
引用
收藏
页码:1580 / 1589
页数:10
相关论文
共 14 条
  • [1] Dynamic contrast-enhanced CT of head and neck tumors: Perfusion measurements using a distributed-parameter tracer kinetic model
    Bisdas, Sotirios
    Cheong, Dennis L. H.
    Lazakidou, Athina
    Tan, Markus C. K.
    Koh, Tong San
    Vogl, Thomas J.
    Baghi, Mehran
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 577 - 580
  • [2] Solitary Pulmonary Nodules: Comparison of Dynamic First-Pass Contrast-enhanced Perfusion Area-Detector CT, Dynamic First-Pass Contrast-enhanced MR Imaging, and FDG PET/CT
    Ohno, Yoshiharu
    Nishio, Mizuho
    Koyama, Hisanobu
    Seki, Shinichiro
    Tsubakimoto, Maho
    Fujisawa, Yasuko
    Yoshikawa, Takeshi
    Matsumoto, Sumiaki
    Sugimura, Kazuro
    [J]. RADIOLOGY, 2015, 274 (02) : 563 - 575
  • [3] Dynamic contrast-enhanced CT of head and neck tumors: perfusion measurements using a distributed-parameter tracer kinetic model. Initial results and comparison with deconvolution-based analysis
    Bisdas, Sotirios
    Konstantinou, George N.
    Lee, Puor Sherng
    Thng, Choon Hua
    Wagenblast, Jens
    Baghi, Mehran
    Koh, Tong San
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (20): : 6181 - 6196
  • [4] Comparison of arterial spin labeling and first-pass dynamic contrast-enhanced MR imaging in the assessment of pulmonary perfusion in humans: The inflow spin-tracer saturation effect
    Lin, YR
    Wu, MT
    Huang, TY
    Tsai, SY
    Chung, HW
    Mai, VM
    Chen, CY
    Pan, HB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (06) : 1291 - 1301
  • [5] Quantitative measurements of perfusion and permeability of oropharyngeal and oral cavity cancer, recurrent disease, and associated lymph nodes using first-pass contrast-enhanced computed tomography studies
    Bisdas, Sotirios
    Baghi, Mehran
    Smolarz, Agnieszka
    Pihno, Nicole Chambron
    Lehnert, Thomas
    Knecht, Rainald
    Mack, Martin G.
    Vogl, Thomas J.
    Tuerkay, Sehib
    Koh, Tong San
    [J]. INVESTIGATIVE RADIOLOGY, 2007, 42 (03) : 172 - 179
  • [6] Assessment of Myocardial Perfusion at Rest and During Stress Using Dynamic First-Pass Contrast-Enhanced Magnetic Resonance Imaging in Healthy Dogs
    Richter, Henning
    Kircher, Patrick R.
    Joerger, Fabiola B.
    Bruellmann, Erika
    Dennler, Matthias
    [J]. FRONTIERS IN VETERINARY SCIENCE, 2018, 5
  • [7] Comparison of setup accuracy of two commercially available immobilization systems for the treatment of head and neck tumors using simulation CT imaging
    Rotondo, RL
    Sultanem, K
    Lavoie, L
    Skelly, J
    Raymond, L
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S54 - S54
  • [8] Comparison of setup accuracy of two commercially available immobilization systems for the treatment of head and neck tumors using simulation CT imaging
    Rotondo, R.
    Sultanem, K.
    Lavoie, I.
    Skelly, J.
    Raymond, L.
    [J]. EJC SUPPLEMENTS, 2005, 3 (02): : 403 - 403
  • [9] Measurement of perfusion using the first-pass dynamic susceptibility-weighted contrast-enhanced (DSC) MRI in neurooncology. Physical basics and clinical applications
    Weber, MA
    Risse, F
    Giesel, FL
    Schad, LR
    Kauczor, HU
    Essig, M
    [J]. RADIOLOGE, 2005, 45 (07): : 618 - 632
  • [10] Quantitative Analysis of First-Pass Contrast-Enhanced Myocardial Perfusion Multidetector CT Using a Patlak Plot Method and Extraction Fraction Correction During Adenosine Stress
    Ichihara, Takashi
    George, Richard T.
    Silva, Caterina
    Lima, Joao A. C.
    Lardo, Albert C.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 133 - 138