Electrical conductivity of medium voltage XLPE insulated cables

被引:0
|
作者
Hestad, Oystein Leif [1 ]
Mauseth, Frank [2 ]
Kyte, Ruth Helene [2 ]
机构
[1] SINTEF Energy Res, Elect Power Technol, Trondheim, Norway
[2] Norwegian Univ Sci & Technol, Dept Elect Power Engn, Trondheim, Norway
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Improved knowledge on the charge transport phenomena in XLPE is important to control the field distribution in the cable insulation, and thus further improve the reliability of future HVDC cables. Polarization and depolarization currents was measured on two medium voltage cables at 40, 60, and 80 degrees C with an applied average electric field varying from 2.5 to 19 kV/mm. The conductivity of the insulation was calculated based on the measured quasi steady state current. The two cables were identical apart from the XLPE material (95mm(2) Cu conductor, 3.4 mm insulation). The field dependence of the conductivity was found to be non-linear for the entire field range. Measured currents were fit to the Poole-Frenkel and hopping conduction. The fit to Poole-Frenkel gave a relative permittivity of 2.9, while the fit to hopping conduction gave an average hopping distance of 19 nm. The best fit to the measurements was obtained with Poole-Frenkel conductivity. The temperature dependence follows an Arrhenius relation with activation energy of approximately 1.4-1.6 eV.
引用
收藏
页码:376 / 380
页数:5
相关论文
共 50 条
  • [1] On-Site Diagnostic Tests on Medium Voltage, XLPE-Insulated Power Cables
    Abou Dakka, Mahmoud
    Bulinski, Alexander
    Bamji, Soli
    [J]. 2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 3019 - 3024
  • [2] Severe Degradation of the Conductor Screen of Service and Laboratory Aged Medium Voltage XLPE Insulated Cables
    Hvidsten, Sverre
    Kvande, Stine
    Ryen, Arve
    Larsen, Per Bjorn
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (01) : 155 - 161
  • [3] Water Tree Detection in Medium Voltage XLPE Cables
    McDermid, W.
    Partyka, M.
    Black, T.
    [J]. 2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 217 - 220
  • [4] Influence of conditioning and features on the electrical breakdown of XLPE insulated power cables
    Kryszak, B
    Jenkins, N
    Le Poidevin, G
    Naybour, RD
    [J]. 2000 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS. I & II, 2000, : 608 - 612
  • [5] ELECTRICAL BREAKDOWN CHARACTERISTICS AND TESTING OF HIGH-VOLTAGE XLPE AND ELECTRON-PARAMAGNETIC-RES INSULATED CABLES
    BAHDER, G
    SOSNOWSKI, M
    KATZ, C
    EATON, R
    KLEIN, K
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (07): : 2173 - 2185
  • [6] Diagnosis of medium voltage XLPE cables by high voltage dielectric spectroscopy
    Werelius, P
    Holmgren, B
    Gafvert, U
    [J]. PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS - ICSD '98, 1998, : 79 - 84
  • [7] POLYETHYLENE-INSULATED CABLES IN MEDIUM VOLTAGE SYSTEM
    ILLERS, F
    KUHMANN, H
    [J]. ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1969, 21 (24): : 555 - &
  • [8] LOW-TEMPERATURE AGING OF XLPE AND EP INSULATED CABLES WITH VOLTAGE TRANSIENTS
    KATZ, C
    SEMAN, GW
    BERNSTEIN, BS
    BROWN, M
    KATZ, C
    SEMAN, GW
    BERNSTEIN, BS
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (01) : 34 - 42
  • [9] EXPERIENCE WITH HIGH-VOLTAGE XLPE INSULATED POWER-CABLES IN NORWAY
    BJORLOWLARSEN, K
    HOLTE, TA
    LARSEN, PB
    [J]. ELECTRICAL COMMUNICATION, 1985, 59 (04): : 446 - 450
  • [10] Development of insulation monitoring system for medium voltage XLPE cables
    Tosaka, S
    Shishido, Y
    Sasaki, N
    Ikeuchi, S
    Ebinuma, Y
    [J]. JOINT CONFERENCE OF 96' AICDEI / 4T-JCCEID, 1996, : 369 - 372