The reactivity of CuO oxygen carrier and coal in Chemical-Looping with Oxygen Uncoupled (CLOU) and In-situ Gasification Chemical-Looping Combustion (iG-CLC)

被引:38
|
作者
Wang, Ping [1 ]
Means, Nicholas [1 ,2 ]
Howard, Bret H. [1 ]
Shekhawat, Dushyant [3 ]
Berry, David [3 ]
机构
[1] NETL, DOE, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USA
[2] AECOM, 626 Cochrans Mill Rd,POB 10940, Pittsburgh, PA 15236 USA
[3] NETL, DOE, 3610 Collins Ferry Rd, Morgantown, WV 26507 USA
关键词
CuO oxygen carrier; Coal; Chemical-looping; iG-CLC; CLOU; Reactivity; SOLID FUELS; UNIT; PERFORMANCE; WASTE;
D O I
10.1016/j.fuel.2017.12.102
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Chemical-looping combustion (CLC) has the primary advantage of the generation of a CO2 enriched flue gas, which greatly benefits CO2 capture. Many researchers have been particularly interested in developing combined or mixed oxygen carriers (OC) to enhance and improve single metal OC properties. To advance the development of mixed OC, this study first focused on the conditions that impact the chemical reactions taking place in both In-situ Gasification Chemical-Looping Combustion (iG-CLC) and Chemical-Looping with Oxygen Uncoupled (CLOU) for single metal Cu based OC with coal and the gas product distributions. The Cu compounds present during CuO reduction (CuO -> Cu2O -> Cu) were also investigated using X-ray diffraction (XRD) as a function of carbon conversion during the reaction. In this study, the reactivity of char with CuO was tested at two different ratios of CuO to coal char (phi = 26 and 8) at 850 degrees C and 950 degrees C in Ar and Ar + H2O. Char conversion rates were greater at higher reaction temperatures (950 degrees C vs 850 degrees C) for all rests. At a high ratio of oxygen carrier to char (phi = 26), char was fully converted by reacting with O-2 released from CuO at both 950 degrees C and 850 degrees C in Ar. CuO was reduced to Cu2O resulting from the thermal release of gaseous oxygen. At a low ratio of oxygen carrier to char under Ar + H2O (phi = 8), char was fully converted at both 950 degrees C and 850 degrees C by char combustion with O-2 from the OC and syngas CLC from char-H2O gasification. Additionally, CuO was reduced to metallic Cu. IG-CLC had a lower CO2 capture efficiency with CO in the product gas and a lower carbon conversion rate compared to CLOU. From a reactivity view point, CLOU is a promising process for coal chemical-looping combustion.
引用
收藏
页码:642 / 649
页数:8
相关论文
共 50 条
  • [1] Continuous regime of chemical-looping combustion (CLC) and chemical-looping with oxygen uncoupling (CLOU) reactivity of CuO oxygen carriers
    Zhou, Zhiquan
    Han, Lu
    Nordness, Oscar
    Bollas, George M.
    [J]. APPLIED CATALYSIS B-ENVIRONMENTAL, 2015, 166 : 132 - 144
  • [2] Manganese ores as oxygen carriers for chemical-looping combustion (CLC) and chemical-looping with oxygen uncoupling (CLOU)
    Sundqvist, Sebastian
    Khalilian, Nazli
    Leion, Henrik
    Mattisson, Tobias
    Lyngfelt, Anders
    [J]. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2017, 5 (03): : 2552 - 2563
  • [3] Investigation of reactivities of bimetallic Cu-Fe oxygen carriers with coal in high temperature in-situ gasification chemical-looping combustion (iG-CLC) and chemical-looping with oxygen uncoupling (CLOU) using a fixed bed reactor
    Wang, Ping
    Howard, Bret
    Means, Nicholas
    [J]. FUEL, 2021, 285
  • [4] Mechanism Analysis of Coal with CuO in the In Situ Gasification Chemical-Looping Combustion and In Situ Gasification Chemical-Looping with Oxygen Uncoupling Process
    Kuang, Cao
    Wang, Shuzhong
    Luo, Ming
    Zhao, Jun
    [J]. ENERGY & FUELS, 2021, 35 (01) : 618 - 625
  • [5] Screening of different manganese ores for chemical-looping combustion (CLC) and chemical-looping with oxygen uncoupling (CLOU)
    Sundqvist, Sebastian
    Arjmand, Mehdi
    Mattisson, Tobias
    Ryden, Magnus
    Lyngfelt, Anders
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2015, 43 : 179 - 188
  • [6] Analysis of Reactivity of CuO Oxygen Carrier During Chemical-Looping Combustion of Coal
    Wang, Guoxian
    Wang, Shuzhong
    Luo, Ming
    [J]. 2010 THE SECOND CHINA ENERGY SCIENTIST FORUM, VOL 1-3, 2010, : 1264 - 1269
  • [7] A comparative process study of chemical-looping combustion (CLC) and chemical-looping with oxygen uncoupling (CLOU) for solid fuels
    Sahir, Asad H.
    Dansie, James K.
    Cadore, Artur L.
    Lighty, Joann S.
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2014, 22 : 237 - 243
  • [8] An investigation of steam production in chemical-looping combustion (CLC) and chemical-looping with oxygen uncoupling (CLOU) for solid fuels
    Dansie, J. K.
    Sahir, A. H.
    Hamilton, M. A.
    Lighty, J. S.
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2015, 94 : 12 - 17
  • [9] Process Comparison for Biomass Combustion: InSitu Gasification-Chemical Looping Combustion (iG-CLC) versus Chemical Looping with Oxygen Uncoupling (CLOU)
    Mendiara, T.
    Adanez-Rubio, I.
    Gayan, P.
    Abad, A.
    de Diego, L. F.
    Garcia-Labiano, F.
    Adanez, J.
    [J]. ENERGY TECHNOLOGY, 2016, 4 (10) : 1130 - 1136
  • [10] Sulfur fate during in-situ gasification chemical looping combustion (iG-CLC) of coal
    Ma, Jinchen
    Mei, Daofeng
    Wang, Chaoquan
    Tian, Xin
    Liu, Zhaohui
    Zhao, Haibo
    [J]. CHEMICAL ENGINEERING JOURNAL, 2021, 406