Ion chamber arrays for the NuMI beam at Fermilab

被引:0
|
作者
Indurthy, D [1 ]
Pavolovic, Z [1 ]
Zwaska, R [1 ]
Kiesler, R [1 ]
Mendoza, S [1 ]
Kopp, S [1 ]
Proga, M [1 ]
Harris, D [1 ]
Marchionni, A [1 ]
Morfin, J [1 ]
Erwin, A [1 ]
Ping, H [1 ]
Velissaris, C [1 ]
Bishai, M [1 ]
Diwan, M [1 ]
Viren, B [1 ]
Naples, D [1 ]
Northacker, D [1 ]
McDonald, J [1 ]
机构
[1] Univ Texas, Austin, TX 78712 USA
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Neutrinos at the Main Injector (NuMI) beamline will deliver an intense v. beam by focusing a beam of mesons into a long evacuated decay volume. We have built 4 arrays of ionization chambers to monitor the v beam direction and quality. The arrays are located at 4 stations downstream of the decay volume, and measure the remnant hadron beam and tertiary mucus produced along with neutrinos in meson decays.
引用
收藏
页码:2448 / 2450
页数:3
相关论文
共 50 条
  • [1] Ion chambers for monitoring the NuMI neutrino beam at Fermilab
    Indurthy, D
    Keisler, R
    Kopp, S
    Mendoza, S
    Proga, M
    Pavlovich, Z
    Zwaska, R
    Harris, D
    Marchionni, A
    Morfin, J
    Erwin, A
    Ping, H
    Velissaris, C
    Naples, D
    Northacker, D
    McDonald, J
    Diwan, M
    Viren, B
    BEAM INSTRUMENTATION WORKSHOP 2004, 2004, 732 : 332 - 340
  • [2] The NuMI neutrino beam at Fermilab
    Kopp, S
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 71 - 73
  • [3] The PEANUT experiment in the NuMI beam at Fermilab
    Russo, A.
    NEUTRINO FACTORIES, SUPERBEAMS, AND BETA BEAMS, 2010, 1222 : 131 - 134
  • [4] Status of the NuMI neutrino beam at Fermilab
    Zwaska, R. M.
    Adamson, P.
    Childress, S. C.
    Hylen, J.
    Kobilarcik, T.
    Koizumi, G. M.
    Lucas, P. W.
    Marchionni, A.
    Martens, M. A.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 2530 - 2530
  • [5] Profile monitor SEMs for the NuMI beam at Fermilab
    Indurthy, D
    Kopp, S
    Proga, M
    Pavlovich, Z
    BEAM INSTRUMENTATION WORKSHOP 2004, 2004, 732 : 341 - 349
  • [6] Off-axis experiment in the NuMI beam at fermilab
    Wojcicki, S
    NEURINO OSCILLATIONS AND THEIR ORIGIN, 2004, : 139 - 146
  • [7] Neutrino scattering physics opportunities with the NuMI beam at Fermilab
    Morfín, JG
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2002, 112 : 251 - 264
  • [8] Synchronization of the 14 kTon NOυA neutrino detector with the Fermilab NuMI beam
    Niner, E.
    Adamson, P.
    Deuerling, G.
    Kwarciany, R.
    Meyer, H.
    Norman, A.
    Rechenmacher, R.
    Shanahan, P.
    Wilcer, N.
    20TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP2013), PARTS 1-6, 2014, 513
  • [9] Upgrades to the Fermilab numi beamline
    Martens, Michael A.
    Childress, Sam
    Grossman, Nancy
    Hurh, Patrick
    Hylen, James
    Marchionni, Alberto
    McCluskey, Elaine
    Moore, Craig Damon
    Reilly, Robert
    Tariq, Salman
    Wehmann, Alan
    Williams, Karlton
    Zwaska, Robert Miles
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 2933 - 2935
  • [10] The ArgoNeuT detector in the NuMI low-energy beam line at Fermilab
    Anderson, C.
    Antonello, M.
    Baller, B.
    Bolton, T.
    Bromberg, C.
    Cavanna, F.
    Church, E.
    Edmunds, D.
    Ereditato, A.
    Farooq, S.
    Fleming, B.
    Greenlee, H.
    Guenette, R.
    Haug, S.
    Horton-Smith, G.
    James, C.
    Klein, E.
    Lang, K.
    Lathrop, A.
    Laurens, P.
    Linden, S.
    McKee, D.
    Mehdiyev, R.
    Page, B.
    Palamara, O.
    Partyka, K.
    Pordes, S.
    Rameika, G.
    Rebel, B.
    Rossi, B.
    Sanders, R.
    Soderberg, M.
    Spitz, J.
    Szelc, A. M.
    Weber, M.
    Wongjirad, T.
    Yang, T.
    Zeller, G. P.
    JOURNAL OF INSTRUMENTATION, 2012, 7