Cavity ring down spectroscopy: detection of trace amounts of substance

被引:25
|
作者
Stacewicz, T. [1 ]
Wojtas, J. [2 ]
Bielecki, Z. [2 ]
Nowakowski, M. [2 ]
Mikolajczyk, J. [2 ]
Medrzycki, R. [2 ]
Rutecka, B. [2 ]
机构
[1] Univ Warsaw, Inst Expt Phys, PL-00068 Warsaw, Poland
[2] Mil Univ Technol, PL-00908 Warsaw, Poland
关键词
trace matter detection; absorption spectroscopy; laser spectroscopy; ENHANCED ABSORPTION-SPECTROSCOPY; NITROGEN-DIOXIDE; NO2;
D O I
10.2478/s11772-012-0006-1
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We describe several applications of cavity ring-down spectroscopy (CRDS) for trace matter detection. NO2 sensor was constructed in our team using this technique and blue-violet lasers (395-440 nm). Its sensitivity is better than single ppb. CRDS at 627 nm was used for detection of NO3. Successful monitoring of N2O in air requires high precision mid-infrared spectroscopy. These sensors might be used for atmospheric purity monitoring as well as for explosives detection. Here, the spectroscopy on sharp vibronic molecular resonances is performed. Therefore the single mode lasers which can be tuned to selected molecular lines are used. Similarly, the spectroscopy at 936 nm was used for sensitive water vapour detection. The opportunity of construction of H2O sensor reaching the sensitivity about 10 ppb is also discussed.
引用
收藏
页码:53 / 60
页数:8
相关论文
共 50 条
  • [1] TRACE GAS-DETECTION WITH CAVITY RING DOWN SPECTROSCOPY
    JONGMA, RT
    BOOGAARTS, MGH
    HOLLEMAN, I
    MEIJER, G
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (04): : 2821 - 2828
  • [2] Cavity ring-down spectroscopy for trace ammonia detection
    Qu Zhe-Chao
    Li Bin-Cheng
    Han Yan-Ling
    [J]. JOURNAL OF INFRARED AND MILLIMETER WAVES, 2012, 31 (05) : 431 - 436
  • [3] Trace Methane Detection Based on Cavity Ring-Down Spectroscopy
    Song Shao-man
    Yan Chang-xiang
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (07) : 2023 - 2028
  • [4] Trace water detection in phosphine by cavity ring-down spectroscopy
    Lehman, SY
    Bertness, KA
    Hodges, JT
    [J]. PROGRESS IN SEMICONDUCTORS II- ELECTRONIC AND OPTOELECTRONIC APPLICATIONS, 2003, 744 : 419 - 424
  • [5] Detection of trace water in phosphine with cavity ring-down spectroscopy
    Lehman, SY
    Bertness, KA
    Hodges, JT
    [J]. JOURNAL OF CRYSTAL GROWTH, 2003, 250 (1-2) : 262 - 268
  • [6] Trace gas detection with DFB lasers and cavity ring-down spectroscopy
    Morville, J
    Chenevier, M
    Kachanov, AA
    Romanini, D
    [J]. OPTICAL SPECTROSCOPIC TECHNIQUES, REMOTE SENSING, AND INSTRUMENTATION FOR ATMOSPHERIC AND SPACE RESEARCH IV, 2001, 4485 : 236 - 243
  • [7] Evanescent wave cavity ring-down spectroscopy for trace water detection
    Pipino, ACR
    Hodges, JT
    [J]. ADVANCED ENVIRONMENTAL AND CHEMICAL SENSING TECHNOLOGY, 2001, 4205 : 1 - 11
  • [8] Detection of Trace Amounts of NO2 Using Frequency Modulated Off-Axis Cavity Ring-Down Spectroscopy
    Karpf, Andreas
    Rao, Gottipaty N.
    [J]. 2012 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2012,
  • [9] Trace gas detection of nitrogen dioxide using cavity ring-down spectroscopy
    Dudek, John
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [10] Trace gas detection with CW cavity ring-down laser absorption spectroscopy
    Yan, WB
    Dudek, J
    Lehmann, K
    Rabinowitz, P
    [J]. 2000 IEEE/SEMI ADVANCED SEMICONDUCTOR MANUFACTURING CONFERENCE AND WORKSHOP, 2000, : 203 - 206