Real-time PC-based system for dynamic beat-to-beat QT-RR analysis

被引:8
|
作者
Govreen-Segal, D [1 ]
Radai, MM
Sivan, Y
Abboud, S
机构
[1] Tel Aviv Univ, Dept Biomed Engn, IL-69978 Tel Aviv, Israel
[2] Tel Aviv Med Ctr, Dana Childrens Hosp, Pediat Intens Care Unit, IL-64239 Tel Aviv, Israel
来源
COMPUTERS AND BIOMEDICAL RESEARCH | 1999年 / 32卷 / 04期
关键词
real-time ECG analyzer; QT and RR intervals; spectral analysis;
D O I
10.1006/cbmr.1999.1514
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A real-time analysis (RTA) system, based on a personal computer with a digital signal processor card (DSP) was developed. The system extracts and saves the QT and RR intervals from an incoming ECG signal sampled at 1 kHz. The method of defining the QT and RR intervals is based on performing multiple cross-correlations that enables rejection of artifacts from the analysis. The relationship between the RR and the Qr intervals is found using the following general formula QT(i) = cRR(i-1)(b). Linear regression is performed on the logarithms of QT and RR measurements obtained to estimate a constant (a = logc) and a slope (b), reflecting the dynamic change of the QT intervals. Having these two values, the dynamic QT extrapolated to a heart period of 1 s (QTcd) was calculated. The system also performs spectral analysis of the intervals and dynamic QT-RR relation-analysis. The system was evaluated oil recordings from 10 infants aged 4 to 24 weeks. The QT/RR computerized measuring device used in the present study answers to the requirements for precise dynamic beat-to-beat QT measurement. its sampling rate is high and can achieve a real millisecond-precision without the need of interpolation methods. The measurements are performed on-line, at the time of the actual recording. Results appear immediately and a measure of dynamic QT behavior can be easily obtained within minutes. The computerized system with the dynamic QT-RR measurements may provide a simple and accurate tool for testing drug treatment and effects of other interventions for cardiac disorders and arrhythmia risk. (C) 1999 Academic Press.
引用
收藏
页码:336 / 354
页数:19
相关论文
共 50 条
  • [1] Effect of ischemic stroke on the dynamic beat-to-beat QT-RR relationship
    Arad, M
    Abboud, S
    Radai, MM
    Adunsky, A
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (03): : 323 - 328
  • [2] Real-time multichannel system for beat-to-beat QT interval variability
    Starc, Vito
    Schlegel, Todd T.
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2006, 39 (04) : 358 - 367
  • [3] The impact of varying autonomic states on the dynamic beat-to-beat QT-RR and QT-TQ interval relationships
    Fossa, A. A.
    [J]. BRITISH JOURNAL OF PHARMACOLOGY, 2008, 154 (07) : 1508 - 1515
  • [4] A Novel Technique for Analysing Beat-to-beat Dynamical Changes of QT-RR Distribution for Arrhythmia Prediction
    Imam, Mohammad Hasan
    Karmakar, Chandan
    Khandoker, Ahsan
    Palaniswami, Marimuthu
    [J]. 2015 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2015, 42 : 1157 - 1160
  • [5] The relationship of clinical QT prolongation to outcome in the conscious dog using a beat-to-beat QT-RR interval assessment
    Fossa, AA
    Depasquale, MJ
    Raunig, DL
    Avery, MJ
    Leishman, DJ
    [J]. JOURNAL OF PHARMACOLOGY AND EXPERIMENTAL THERAPEUTICS, 2002, 302 (02): : 828 - 833
  • [6] Dynamic beat-to-beat QT-RR relationship during physiotherapy effort in elderly patients without primary heart disease
    Arad, M
    Abboud, S
    Radai, MM
    Elion, G
    Bar-Nachum, S
    Zohar, M
    Adunsky, AH
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (08): : 1240 - 1244
  • [7] Dynamic beat to beat QT-RR relationship during the exercise and recovery phases of cycle ergometer test
    Abboud, S
    Radai, M
    GovreenSegal, D
    Goldstein, A
    Strasberg, B
    [J]. EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 145 - 149
  • [8] A method for QT correction based on beat-to-beat analysis of the QT/RR interval relationship in conscious telemetred beagle dogs
    Batey, AJ
    Doe, CPA
    [J]. JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2002, 48 (01) : 11 - 19
  • [9] Automatic Real-time Beat-to-beat Detection of Arrhythmia Conditions
    Rosa, Giovanni
    Laudato, Gennaro
    Colavita, Angela Rita
    Scalabrino, Simone
    Oliveto, Rocco
    [J]. HEALTHINF: PROCEEDINGS OF THE 14TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES - VOL. 5: HEALTHINF, 2021, : 212 - 222
  • [10] Dynamic beat-to-beat Modeling of the QT-RR interval relationship:: Analysis of QT prolongation during alterations of autonomic state versus human ether a-go-go-related gene inhibition
    Fossa, AA
    Wisialowski, T
    Magnano, A
    Wolfgang, E
    Winslow, R
    Gorczyca, W
    Crimin, K
    Raunig, DL
    [J]. JOURNAL OF PHARMACOLOGY AND EXPERIMENTAL THERAPEUTICS, 2005, 312 (01): : 1 - 11