Future of Diagnostic Computed Tomography An Update on Physicochemical Properties, Safety, and Development of X-ray Contrast Media

被引:12
|
作者
Shahid, Imran [1 ]
Lancelot, Eric [1 ]
Desche, Pierre [1 ]
机构
[1] Guerbet, BP57400, F-95943 Roissy, France
关键词
computed tomography; iodinated contrast media; safety; technology; METAANALYSIS; RISK;
D O I
10.1097/RLI.0000000000000686
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Iodinated contrast media (CM) are utilized in approximately 40% of the 300 million computed tomography (CT) scans undertaken annually. This review focuses on the physicochemical properties and safety of iodinated CM, and the development of new x-ray CM, and it explores methods to optimize CT scanning parameters. It concludes that good x-ray CM should have high structural stability, hydrophilicity, and CT attenuation; low viscosity, osmolality, and protein binding; no metabolism and tissue accumulation; and a complete elimination.
引用
收藏
页码:598 / 600
页数:3
相关论文
共 50 条
  • [1] Developments in X-Ray Contrast Media and the Potential Impact on Computed Tomography
    Schoeckel, Laura
    Jost, Gregor
    Seidensticker, Peter
    Lengsfeld, Philipp
    Palkowitsch, Petra
    Pietsch, Hubertus
    INVESTIGATIVE RADIOLOGY, 2020, 55 (09) : 592 - 597
  • [2] Review Safety of diagnostic imaging in pregnancy. Part 1: X-ray, nuclear medicine investigations, computed tomography and contrast media
    Eskandar, Osama S.
    Eckford, Seumas D.
    Watkinson, Tony
    OBSTETRICIAN & GYNAECOLOGIST, 2010, 12 (02): : 71 - 78
  • [3] Safety of diagnostic imaging in pregnancy. Part 1: X-ray, nuclear medicine investigations, computed tomography and contrast media Reply
    Eskandar, Osama
    Eckford, Seumas
    Watkinson, Tony
    OBSTETRICIAN & GYNAECOLOGIST, 2010, 12 (03): : 214 - 215
  • [4] PHYSICOCHEMICAL PARAMETERS OF X-RAY CONTRAST-MEDIA
    KRAUSE, W
    MIKLAUTZ, H
    KOLLENKIRCHEN, U
    HEIMANN, G
    INVESTIGATIVE RADIOLOGY, 1994, 29 (01) : 72 - 80
  • [5] Contrast agents for x-ray luminescence computed tomography
    Lun, Michael C.
    Ranasinghe, Meenakshi
    Arifuzzaman, Mohammad
    Fang, Yile
    Guo, Yiping
    Anker, Jeffrey N.
    Li, Changqing
    APPLIED OPTICS, 2021, 60 (23) : 6769 - 6775
  • [6] Development of dimensional X-ray computed tomography
    National Metrology Institute of Japan , National Institute of Advanced Industrial Science and Technology , 1-1-1 Umezono, Tsukuba
    Ibaraki
    305-8563, Japan
    Int. J. Autom. Technol., 5 (567-571):
  • [7] X-ray computed tomography contrast agents for cartilage imaging
    Lusic, Hrvoje
    Freedman, Jonathan D.
    Snyder, Brian D.
    Grinstaff, Mark W.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [8] Contrast agents for soil investigation with X-ray computed tomography
    Van Loo, Denis
    Bouckaert, Liesbeth
    Leroux, Olivier
    Pauwels, Elin
    Dierick, Manuel
    Van Hoorebeke, Luc
    Cnudde, Veerle
    De Neve, Stefaan
    Sleutel, Steven
    GEODERMA, 2014, 213 : 485 - 491
  • [9] Helical x-ray differential phase contrast computed tomography
    Qi, Zhihua
    Theriault-Lauzier, Pascal
    Bevins, Nicholas
    Zambelli, Joseph
    Li, Ke
    Chen, Guang-Hong
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [10] Bismuth chelate as a contrast agent for X-ray computed tomography
    Ji-jun Fu
    Jun-jie Guo
    Ai-ping Qin
    Xi-yong Yu
    Qiang Zhang
    Xue-ping Lei
    Yu-gang Huang
    Ming-yue Chen
    Jie-xia Li
    Yu Zhang
    Jing-ping Liu
    Yuan-ye Dang
    Dan Wu
    Xiao-ya Zhao
    Zhong-xiao Lin
    Yin-lei Lin
    Song-pei Li
    Ling-yan Zhang
    Journal of Nanobiotechnology, 18