Study on DFIG Stator Turn - to - Turn Short Circuit Considering Control Strategy

被引:0
|
作者
Li Junqing [1 ]
Tong Zongyi [1 ]
Li Zhonghui [1 ]
机构
[1] North China Elect Power Univ Baoding, Sch Elect & Elect Engn, Baoding, Peoples R China
关键词
DFIG; Stator inter-turn short-circuit fault; control strategy; the multi - loop theory; LOW-VOLTAGE RIDE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Stator inter-turn short circuit fault is one of the common faults in Double Fed Induction Generator (DFIG), the mathematical model of the DFIG is established based on the multi - loop theory, and the model of DFIG is built on the MATLAB / Simulink platform under normal condition and different degrees of inter - turn short circuit. The mathematical model of the grid side converter is analyzed to determine the corresponding control strategy, and the concrete given process of the PI regulator parameters is given. Through the simulation analysis of the DFIG under different conditions, the simulation results are consistent with the actual situation, which proves the feasibility of the control strategy. When the stator occurs turns short-circuit, the stator three-phase current is not symmetrical and its corresponding amplitude is increased, there is more obvious 90Hz specific frequency harmonics in rotor-side current FFT.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Comprehensive Modeling and Analysis of Stator Turn-to-Turn Short-Circuit Faults in a DFIG
    Yan, Chenguang
    Wang, Weixiang
    Liu, Qinzhi
    Liu, Zhangheng
    Shu, Jin
    Zhao, Jikai
    Zhang, Baohui
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (08)
  • [2] Vibration Analysis of DFIG Stator Winding Inter-turn Short Circuit Fault
    Qin, Peng
    Zhang, Zhiyan
    Sun, Yusheng
    Liu, Hua
    Ren, Haizhou
    PROCEEDINGS OF 2018 INTERNATIONAL CONFERENCE ON INFORMATION SYSTEMS AND COMPUTER AIDED EDUCATION (ICISCAE 2018), 2018, : 436 - 442
  • [3] Experimental Research and Feature Extraction on Stator Inter-turn Short Circuit Fault in DFIG
    Zhao, Yihan
    Chen, Yu
    Wang, Lulu
    Rehman, Attiq Ur
    Cheng, Yonghong
    Zhao, Yong
    Han, Bin
    Tanaka, Toshikatsu
    2016 IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), VOLS 1-2, 2016, : 510 - 513
  • [4] Model and Transient Analysis of Stator Inter-turn Short-circuit Fault in DFIG
    Qian Yanping
    Zhu Ligui
    Wang Bing
    PROCEEDINGS OF THE 31ST CHINESE CONTROL CONFERENCE, 2012, : 6752 - 6757
  • [5] The Effect of Stator Inter-Turn Short-Circuit Fault on DFIG Performance Using FEM
    Mellah, Hacene
    Arslan, Serdal
    Hamza, Sahraoui
    Hemsas, Kamel Eddine
    Kamel, Saoudi
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2022, 12 (03) : 8688 - 8693
  • [6] A Reconfigure Modelling of Double Stator PMSM after Turn-to-Turn Short Circuit
    Li Hao
    Schaeffer, Emmanuel
    Tang Tianhao
    ICINCO: PROCEEDINGS OF THE 16TH INTERNATIONAL CONFERENCE ON INFORMATICS IN CONTROL, AUTOMATION AND ROBOTICS, VOL 1, 2019, : 609 - 616
  • [7] Fault Diagnosis of Stator Winding Turn to Turn Short Circuit of Synchronous Rectifier Generator
    Zhang, Jingnan
    Wu, Liqin
    Zhang, Tianhao
    2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 2001 - 2005
  • [9] A Fault Diagnosis Strategy for Stator Windings Inter-turn Short Circuit of Synchronous Condenser
    Wang, Xiaohu
    Xu, Songmei
    Ye, Yuanling
    Tian, Weijie
    Yang, Chaowei
    Wang, Wei
    Wei, Chao
    2021 24TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2021), 2021, : 2616 - 2620
  • [10] Diagnosis of stator winding inter-turn short circuit in DFIG based on instantaneous average power in rotor side
    Ma H.
    Zhang Y.
    Wei H.
    Fu M.
    Huang C.
    2018, Electric Power Automation Equipment Press (38): : 151 - 156