On the behavior of fc,Q factors with quality indexes for medium energy X-ray beams: A Monte Carlo study with PENELOPE

被引:1
|
作者
Chica, U. [1 ,2 ]
Anguiano, M. [1 ]
Lallena, A. M. [1 ]
机构
[1] Univ Granada, Dept Fis Atom Mol & Nucl, E-18071 Granada, Spain
[2] Fdn Clin Shaio, Serv Radiocirugia, Bogota, Colombia
关键词
f(c; Q); factors; Medium energy X-rays; PENELOPE; 300; KV; DOSIMETRY; SPECTRA; CHAMBER; TUBE; RADIOTHERAPY; IPEMB; CODE; HVL;
D O I
10.1016/j.radphyschem.2013.03.034
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A series of Monte Carlo simulations has been performed to determine the behavior of the factor f(c,Q) as a function, of the usual quality indexes for medium energy X-ray beams. Up to 46 beams, with spectra generated with the codes XCOMP5R and SPEKCALC, for potentials up to 300 kV, were transported using the Monte Carlo code PENELOPE to calculate the doses in water and in a PTW 30001 ionization chamber, both at the reference depth. The half-value layer (the usual quality index for these beams) and other two quality indexes, the generating potential and the homogeneity coefficient, have been considered. The calculated f(c,Q) factors are well described with a function that involves the power of the half-value layer up to the square and a second quality index linearly. The predictive power of this combination has been studied. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:73 / 78
页数:6
相关论文
共 50 条
  • [1] Quality indexes based on water measurements for low and medium energy x-ray beams: A theoretical study with PENELOPE
    Chica, U.
    Anguiano, M.
    Vilches, M.
    Lallena, A. M.
    [J]. MEDICAL PHYSICS, 2014, 41 (01)
  • [2] Monte Carlo (PENELOPE code) study of the x-ray beams from SL Linacs (Elekta)
    Bramoullé, C
    Husson, F
    Manens, JP
    [J]. PHYSICA MEDICA, 2000, 16 (03) : 107 - 115
  • [3] Monte Carlo and Water Calorimetric Determination of Ionization Chamber Correction Factors for Medium Energy X-Ray Beams
    Bancheri, J.
    Ketelhut, S.
    Bueermann, L.
    Seuntjens, J.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E816 - E816
  • [4] Monte Carlo calculation of quality correction factors based on air kerma and absorbed dose to water in medium energy x-ray beams
    Czarnecki, Damian
    Zink, Klemens
    Pimpinella, Maria
    Borbinha, Jorge
    Teles, Pedro
    Pinto, Massimo
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24):
  • [5] Monte Carlo simulation of x-ray tube spectra with PENELOPE
    Jia, Pengxiang
    Xie, Yaoqin
    Bao, Shanglian
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 503 - 506
  • [6] X-ray simulation with the Monte Carlo code PENELOPE. Application to Quality Control
    Pozuelo, F.
    Gallardo, S.
    Querol, A.
    Verdu, G.
    Rodenas, J.
    [J]. 2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 5777 - 5780
  • [7] ENERGY CORRECTION FACTORS FOR EPR DOSIMETRY OF MEDIUM ENERGY X-RAY BEAMS
    Waldeland, E.
    Hole, E. O.
    Sagstuen, E.
    Malinen, E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S472 - S472
  • [8] Monte Carlo studies on dose conversion factors from graphite to water for high energy X-ray beams
    Kim, Y. H.
    Yi, C. Y.
    Kim, I. J.
    Kim, B. C.
    Kim, J. H.
    Seong, Y. M.
    Kim, H. M.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 171
  • [9] A Monte Carlo study of x-ray fluorescence in x-ray detectors
    Boone, JM
    Seibert, JA
    Sabol, JM
    Tecotzky, M
    [J]. MEDICAL PHYSICS, 1999, 26 (06) : 905 - 916
  • [10] Application of the Monte Carlo codes PENELOPE and MCNP5 to unfold X-ray spectra in the diagnostic energy range
    Gallardo, Sergio
    Querol, Andrea
    Pozuelo, Fausto
    Verdu, Gumersindo
    Rodenas, Jose
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 166 - 169