Electrical and dosimetric characterization of a CVD diamond detector with high sensitivity

被引:9
|
作者
Spadaro, S. [1 ,2 ]
Conte, G. [1 ,2 ]
Pimpinella, M. [3 ]
Guerra, A. S. [3 ]
机构
[1] INFN Roma Tre, Dept Phys Edoardo Amaldi, I-00146 Rome, Italy
[2] Univ Roma Tre, Dept Phys Edoardo Amaldi, I-00146 Rome, Italy
[3] Natl Inst Ionizing Radiat Metrol, ENEA INMRI, I-00123 Rome, Italy
关键词
CVD single crystal diamond; Co-60; dosimetry; Diamond sensitivity; Zero-bias operation; RADIOTHERAPY DOSIMETRY; SINGLE-CRYSTAL;
D O I
10.1016/j.radmeas.2012.11.017
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A prototype detector has been built using commercial high quality single crystal epitaxial diamond and novel electrical contacts resulting in two asymmetric Schottky junctions able to operate the detector at zero bias like a photodiode. Aiming at evaluating the detector suitability for radiotherapy applications we report on results related to signal dynamics, linearity with the dose and dose rate, signal stability and measurement repeatability determined in a Co-60 reference beam. In addition, we measured the detector sensitivity and its dependence on the applied bias voltage. The detector has a wide active volume leading to high current signal values. The signal dynamics is wide, with a dark current of 3.2 x 10(-14) A at zero bias and a current of 6.8 x 10(-10) A under irradiation with a dose rate of 0.95 Gy min(-1). The sensitivity to ionizing radiation increases with the bias voltage and values up to 10(4) nC Gy(-1) mm(-3) have been evaluated at -300 V. When operated at -5 V, the detector shows a linear response on a wide range of Co-60 dose rates from 1.3 x 10(-3) Gy min(-1) to 1.2 Gy min(-1) following the Fowler's power law with a coefficient Delta = 0.99 +/- 0.01. The device also shows rise and fall times of less than 1.0 s with a stability of the signal under irradiation better than 0.3%. The characteristics of the detector, as determined in the Co-60 beam, appear suitable for radiotherapy dosimetry, when fast response on the transient, wide signal dynamics, linearity and high sensitivity are required. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [1] Dosimetric characterization of a 2D polycrystalline CVD diamond detector
    Bartoli, A.
    Cupparo, I.
    Baldi, A.
    Scaringella, M.
    Pasquini, A.
    Pallotta, S.
    Talamonti, C.
    Bruzzi, M.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [2] Dosimetric characterization of radiosurgical beams with a diamond detector
    Rustgi, SN
    Frye, DMD
    MEDICAL PHYSICS, 1995, 22 (12) : 2117 - 2121
  • [3] Polycrystalline CVD diamond detector: Fast response and high sensitivity with large area
    Liu, Linyue
    Ouyang, Xiaoping
    Zhang, Jianfu
    Zhang, Xianpeng
    Zhong, Yunhong
    AIP ADVANCES, 2014, 4 (01)
  • [4] Characterization of CVD diamond films as radiation detectors for dosimetric applications
    Bruzzi, M
    Bucciolini, M
    Cirrone, GAP
    Cuttone, G
    Guasti, A
    Mazzocchi, S
    Pirollo, S
    Sabini, MG
    Sciortino, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1430 - 1433
  • [5] Characterization of CVD diamond films as radiation detectors for dosimetric applications
    Bruzzi, M
    Bucciolini, M
    Cirrone, GAP
    Cuttone, G
    Guasti, A
    Mazzocchi, S
    Pirollo, S
    Sabini, MG
    Sciortino, S
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 121 - 124
  • [6] Electrical properties of CVD diamond detector and detection for alpha particle
    Su, QF
    Xia, YB
    Wang, LJ
    Liu, JM
    Ruan, JF
    Shi, WM
    MODERN PHYSICS LETTERS A, 2005, 20 (38) : 2949 - 2956
  • [7] High electrical resistivity of CVD-diamond
    Manca, JV
    Nesladek, M
    Neelen, M
    Quaeyhaegens, C
    De Schepper, L
    De Ceuninck, W
    MICROELECTRONICS RELIABILITY, 1999, 39 (02) : 269 - 273
  • [8] Dosimetric characterization of a polycrystalline diamond detector prototype in radiotherapy beams
    Fidanzio, A
    Conte, G
    Ascarelli, P
    Azario, L
    Viola, P
    Cappelli, E
    Piermattei, A
    PHYSICA MEDICA, 2002, 18 (04) : 129 - 133
  • [9] High Precision Integrator for CVD-Diamond Detectors for Dosimetric Applications
    D'Antonio, E.
    Salvatori, S.
    Oliva, P.
    Patane, F.
    Girolami, M.
    Trucchi, D. M.
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 112 - 117
  • [10] POLYCRYSTALLINE CVD DIAMOND FILMS WITH HIGH ELECTRICAL MOBILITY
    PLANO, MA
    LANDSTRASS, MI
    PAN, LS
    HAN, S
    KANIA, DR
    MCWILLIAMS, S
    AGER, JW
    SCIENCE, 1993, 260 (5112) : 1310 - 1312