Visual Acuity During Direct Laryngoscopy at Different Illuminance Levels

被引:8
|
作者
Baker, Paul A. [1 ]
Raos, Amy S. [1 ]
Thompson, John M. D. [2 ]
Jacobs, Robert J. [3 ]
机构
[1] Starship Childrens Hlth, Dept Paediat Anaesthesia, Auckland, New Zealand
[2] Univ Auckland, Dept Paediat, Auckland 1142, New Zealand
[3] Univ Auckland, Dept Optometry & Vis Sci, New Zealand Natl Eye Ctr, Auckland 1142, New Zealand
来源
ANESTHESIA AND ANALGESIA | 2013年 / 116卷 / 02期
关键词
LIGHT-INTENSITY; DIFFICULT INTUBATION; BLADES; ANESTHESIA; MANNEQUIN; MINIMUM; VISION; AIRWAY;
D O I
10.1213/ANE.0b013e318273f397
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Adequate light is essential for vision during direct laryngoscopy. The ISO 7376:2009 standard specifies the minimal illuminance for laryngoscopes. No studies have objectively examined the relationship between laryngoscope illumination and visual acuity during laryngoscopy. METHODS: We measured the near visual performance of 50 anesthesiologists during direct laryngoscopy using near vision charts located at the larynx of 4 manikins. A variable voltage supply adjusted the illuminance from the laryngoscope to 50 lux, 200 lux, 700 lux, and 2000 lux. Participants also rated their experience regarding brightness of the laryngoscope, clarity of view, visual performance, and suitability and adequacy of the light, before proceeding to the next manikin with a different light level. The distance visual performance of the participants was also measured using standard letter acuity wall charts at the same light levels. RESULTS: Visual acuity in manikins and on wall charts was associated with an increasing lux level (P < 0.0001). Visual acuity was lower at 50 lux and 200 lux compared with 700 lux by significantly more than the clinically discernible 0.1 logMAR. No statistically significant improvement in visual acuity occurred when illuminance was increased to 2000 lux. The mean (standard deviation) logMAR scores at the 4 chosen lux levels on the manikin charts were: 50 lux 0.05 (0.13), 200 lux 0.06 (0.10), 700 lux -0.05 (0.11), and 2000 lux -0.07 (0.11). This result was unaffected by age, seniority, subspecialty, history of difficulty focusing, or use of lenses for laryngoscopy. Subjective rating of laryngoscope brightness favored 2000 lux for clarity of view, suitability of the light for laryngoscopy, and visual performance. The average observation distance for direct laryngoscopy was 32 cm. CONCLUSIONS: Visual acuity improves as the laryngoscope illuminance increases up to 700 lux. No statistically significant improvement was measured by increasing the illuminance up to 2000 lux. Subjectively, anesthesiologists favor illuminance of 2000 lux for direct laryngoscopy. (Anesth Analg 2013;116:343-50)
引用
收藏
页码:343 / 350
页数:8
相关论文
共 50 条
  • [1] The automatic processing of visual information at different visual acuity levels: An ERP study
    Meng, Huanhuan
    Ji, Mengmeng
    Luo, Bin
    Zhang, Mingyang
    Gao, Yuan
    Ma, Lu
    Shen, Xi
    Luo, Chengliang
    Yang, Xun
    Chen, Xiping
    Tao, Luyang
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2015, 98 (01) : 135 - 142
  • [2] RECOMMENDED ILLUMINANCE LEVELS FOR VISUAL TASKS IN BUILDINGS
    Seangatith, Rojarek
    Chaiyakul, Yingsawad
    SURANAREE JOURNAL OF SCIENCE AND TECHNOLOGY, 2019, 26 (02): : 187 - 197
  • [3] Hypoxaemia during direct laryngoscopy
    Saxena, A
    Bhalotra, AR
    Trikha, A
    Kumar, S
    NATIONAL MEDICAL JOURNAL OF INDIA, 1997, 10 (01): : 46 - 46
  • [4] Asystole during direct laryngoscopy
    Blanie, A.
    Penon, C.
    Edouard, A.
    Benhamou, D.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2006, 25 (08): : 904 - 904
  • [5] VISUAL LATENCIES AT PHOTOPIC LEVELS OF RETINAL ILLUMINANCE
    PRESTRUDE, AM
    VISION RESEARCH, 1971, 11 (04) : 351 - +
  • [6] Effect of illuminance on home measurements of near and distance visual acuity and contrast sensitivity
    Awidi, Abdelhalim
    Almidani, Louay
    Mihailovic, Aleksandra
    Swaminathan, Siva Ram
    Yuan, Zhuochen
    Ramulu, Pradeep Y.
    Awidi, Abdelhalim
    Almidani, Louay
    Mihailovic, Aleksandra
    Swaminathan, Siva Ram
    Yuan, Zhuochen
    Ramulu, Pradeep Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [7] Decreased cerebral oxygen saturation levels during direct laryngoscopy with ventilation in children
    Wasserzug, Oshri
    Fishman, Gadi
    Handzel, Ophir
    Stockie, Daniel
    Oestreicher-Kedem, Yael
    Fliss, Dan M.
    DeRowe, Ari
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2020, 137
  • [8] Previsional space during direct laryngoscopy Implication in the difficult laryngoscopy
    Park, Seongjoo
    Han, Ji-Won
    Cha, Sukwon
    Han, Sung-Hee
    Kim, Jin-Hee
    MEDICINE, 2017, 96 (27)
  • [9] Different trajectories in the development of visual acuity with different levels of crowding: The Milan Eye Chart (MEC)
    Facchin, Alessio
    Maffioletti, Silvio
    Martelli, Marialuisa
    Daini, Roberta
    VISION RESEARCH, 2019, 156 : 10 - 16
  • [10] Peripheral refraction under different levels of illuminance
    Marcellan, Ma Concepcion
    Remon, Laura
    Avila, Francisco J.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2024, 44 (01) : 191 - 198