Reliability of Navigated Lower Limb Alignment in High Tibial Osteotomies

被引:35
|
作者
Goleski, Patrick [1 ,2 ]
Warkentine, Blaine [1 ,3 ]
Lo, Darrick [1 ]
Gyuricza, Cassie [1 ]
Kendoff, Daniel [1 ,4 ]
Pearle, Andrew D. [1 ]
机构
[1] Hosp Special Surg, Dept Orthopaed, New York, NY 10021 USA
[2] Univ Michigan, Sch Med, Ann Arbor, MI USA
[3] BrainLAB USA, Chicago, IL USA
[4] Hannover Med Sch, Trauma Dept, D-3000 Hannover, Germany
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2008年 / 36卷 / 11期
关键词
navigation; high tibial osteotomy; reliability; accuracy; computer-assisted surgery;
D O I
10.1177/0363546508319314
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Navigation allows for determination of the mechanical axis of the lower extremity during high tibial osteotomy (HTO) procedures. The objectives of this study were to (1) evaluate the reliability of noninvasive registration with an image-free navigation system for HTO and (2) determine the accuracy of the navigation system to monitor changes in lower limb alignment as compared with alignment measured with a novel 3-dimensional computed tomography method. Hypothesis: Navigated limb alignment demonstrates good reliability and accuracy in all 3 planes. Study Design: Descriptive laboratory study. Methods: Thirteen cadaver legs were used to examine the intra- and interobserver registration reliability of 3 observers. Initial coronal, sagittal, and axial alignment was measured on 6 legs, 3 times each, at intervals > 36 hours. Navigated HTOs were then performed on all 13 legs, pre- and postoperative alignment was recorded, and data were compared with equivalent measures obtained by 3-dimensional computed tomography. Reliability and accuracy data were both analyzed using intraclass correlation coefficients with the following established thresholds: good, > 0.75; fair, 0.4 to 0.75; and poor, < 0.4. Results: Intraclass correlation coefficients for intraobserver reliability were categorized as follows: varus-valgus, good; flexion-extension, fair; and femoral-tibial rotation, poor. For interobserver reliability, results were varus-valgus, fair; flexion-extension, fair; and femoral-tibial rotation, poor. Intraclass correlation coefficients for navigation accuracy were varus-valgus, good; tibial slope, good; and tibial torsion, poor. Maximum differences in navigation-computed tomography measurements were Delta varus-valgus angle, 4.5 degrees; Delta tibial slope, 8.8 degrees; and Delta tibial torsion, 16.5 degrees. Conclusion and Clinical Relevance: Navigation may be reliable and clinically useful for dynamic monitoring of coronal leg alignment but has limits in determination of sagittal and axial plane alignment.
引用
收藏
页码:2179 / 2186
页数:8
相关论文
共 50 条
  • [1] Influence of lower limb rotation in navigated alignment analysis: implications for high tibial osteotomies
    D. Kendoff
    M. Citak
    A. Pearle
    M. J. Gardner
    S. Hankemeier
    C. Krettek
    T. Hüfner
    Knee Surgery, Sports Traumatology, Arthroscopy, 2007, 15 : 1003 - 1008
  • [2] Influence of lower limb rotation in navigated alignment analysis:: implications for high tibial osteotomies
    Kendoff, D.
    Citak, M.
    Pearle, A.
    Gardner, M. J.
    Hankemeier, S.
    Krettek, C.
    Huefner, T.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2007, 15 (08) : 1003 - 1008
  • [3] Navigated intraoperative analysis of lower limb alignment
    Hankemeier, S
    Hufner, T
    Wang, GL
    Kendoff, D
    Zheng, GY
    Richter, M
    Gosling, T
    Nolte, L
    Krettek, C
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (08) : 531 - 535
  • [4] Navigated intraoperative analysis of lower limb alignment
    Stefan Hankemeier
    Tobias Hufner
    Gongli Wang
    Daniel Kendoff
    Guoyan Zheng
    Martinus Richter
    Thomas Gosling
    Lutz Nolte
    Christian Krettek
    Archives of Orthopaedic and Trauma Surgery, 2005, 125 : 531 - 535
  • [5] RELIABILITY OF LIMB ALIGNMENT MEASUREMENT FOR HIGH TIBIAL OSTEOTOMY WITH A NAVIGATION SYSTEM
    Luetzner, J.
    Gross, A. F.
    Guenther, K. P.
    Kirschner, S.
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2009, 14 (10) : 447 - 450
  • [6] Reliability of limb alignment measurement for high tibial osteotomy with a navigation system
    J Lützner
    AF Groß
    KP Günther
    S Kirschner
    European Journal of Medical Research, 14 (10)
  • [7] Influence of hindfoot alignment on postoperative lower limb alignment in medial opening wedge high tibial osteotomy
    Kotaro Miyazaki
    Akira Maeyama
    Ichiro Yoshimura
    Tomohiro Kobayashi
    Tetsuro Ishimatsu
    Takuaki Yamamoto
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 81 - 90
  • [8] Influence of hindfoot alignment on postoperative lower limb alignment in medial opening wedge high tibial osteotomy
    Miyazaki, Kotaro
    Maeyama, Akira
    Yoshimura, Ichiro
    Kobayashi, Tomohiro
    Ishimatsu, Tetsuro
    Yamamoto, Takuaki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (01) : 81 - 90
  • [9] AXIAL PARAMETERS AFFECTING LOWER-LIMB ALIGNMENT AFTER HIGH TIBIAL OSTEOTOMY
    TERAUCHI, M
    SHIRAKURA, K
    KOBUNA, Y
    FUKASAWA, N
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (317) : 141 - 149
  • [10] Planning of corrective osteotomies of the lower limb
    Lichte, P.
    Kobbe, P.
    Loerken, M.
    Pape, H. -C.
    UNFALLCHIRURG, 2010, 113 (07): : 573 - 583