Uncertainty in measurement for 43 biochemistry, immunoassay, and hemostasis routine analytes evaluated by a method using only external quality assessment data

被引:30
|
作者
Matar, Gladys [1 ]
Poggi, Bernard [1 ,2 ]
Meley, Roland [1 ,3 ]
Bon, Chantal [1 ,2 ]
Chardon, Laurence [1 ,4 ]
Chikh, Karim [1 ,5 ]
Renard, Anne-Claude [1 ]
Sotta, Catherine [1 ]
Eynard, Jean-Christophe [1 ]
Cartier, Regine [1 ,6 ]
Cohen, Richard [1 ,4 ,7 ]
机构
[1] ProBioQual, F-69003 Lyon, France
[2] Hosp Civils Lyon, Hop Croix Rousse, Serv Biochim & Biol Mol, Lyon, France
[3] Serv Hematol, St Etienne, France
[4] Hosp Civils Lyon, Hop Edouard Herriot, Serv Biochim & Biol Mol, Lyon, France
[5] Hosp Civils Lyon, Ctr Hosp Lyon Sud, Serv Biochim & Biol Mol, Pierre Benite, France
[6] Hosp Civils Lyon, Grp Hosp Est, Serv Biochim & Biol Mol, Bron, France
[7] Univ Lyon 1, ISPB Fac Pharm, MATEIS UMR CNRS 5510, Lyon, France
关键词
external quality assessment; internal quality control; long-term analytical coefficient of variation; proficiency testing; uncertainty in measurement;
D O I
10.1515/cclm-2014-0942
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: International organizations require from medical laboratories a quantitative statement of the uncertainty in measurement (UM) to help interpret patient results. The French accreditation body (COFRAC) recommends an approach (SH GTA 14 IQC/EQA method) using both internal quality control (IQC) and external quality assessment (EQA) data. The aim of this work was to validate an alternative way to quantify UM using only EQA results without any need for IQC data. This simple and practical method, which has already been described as the long-term evaluation of the UM (LTUM), is based on linear regression between data obtained by participants in EQA schemes and target values. We used it for 43 routine analytes covering biochemistry, immunoassay, and hemostasis fields. Methods: Data from 50 laboratories participating in ProBioQual (PBQ) EQA schemes over 25 months were used to obtain estimates of the median and 90th percentile LTUM and to compare them to the usual analytical goals. Then, the two UM estimation methods were compared using data from 20 laboratories participating in both IQC and EQA schemes. Results: Median LTUMs ranged from 2.9% (sodium) to 16.3% (bicarbonates) for biochemistry analytes, from 12.6% (prothrombin time) to 18.4% (factor V) for hemostasis analytes when using the mean of all participants, and were around 10% for immunoassays when using the peergroup mean. Median LTUMs were, in most cases, slightly lower than those obtained with the SH GTA 14 method, whatever the concentration level. Conclusions : LTUM is a simple and convenient method that gives UM estimates that are reliable and comparable to those of recommended methods. Therefore, proficiency testing (PT) organizers are allowed to provide participants with an additional UM estimate using only EQA data and which could be updated at the end of each survey.
引用
收藏
页码:1725 / 1736
页数:12
相关论文
共 6 条
  • [1] Uncertainty evaluation in clinical chemistry, immunoassay, hematology and coagulation analytes using only external quality assessment data
    Qin, Yanyan
    Zhou, Rui
    Wang, Wei
    Yin, Hongyi
    Yang, Yanmin
    Yue, Yuhong
    Tong, Qing
    Liu, Lu
    Jin, Yali
    Shi, Yankun
    Zhang, Shunli
    Zhang, Jianping
    Zhang, Rui
    Zuo, Chang
    Jia, Tingting
    Wang, Ning
    Wang, Qingtao
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (09) : 1447 - 1457
  • [2] Routine internal- and external-quality control data in clinical laboratories for estimating measurement and diagnostic uncertainty using GUM principles
    Magnusson, Bertil
    Ossowicki, Haakan
    Rienitz, Olaf
    Theodorsson, Elvar
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2012, 72 (03): : 212 - 220
  • [3] An approach for estimating measurement uncertainty in medical laboratories using data from long-term quality control and external quality assessment schemes
    Padoan, Andrea
    Antonelli, Giorgia
    Aita, Ada
    Sciacovelli, Laura
    Plebani, Mario
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (11) : 1696 - 1701
  • [4] Determining of acceptable limits of uncertainties in radiotoxicology by using a method based only on external quality assessment results
    Guichet, C.
    Hurtgen, C.
    RADIOPROTECTION, 2017, 52 (02) : 125 - 139
  • [5] AN EXAMINATION OF THE HEXOKINASE METHOD FOR SERUM GLUCOSE ASSAY USING EXTERNAL QUALITY ASSESSMENT DATA
    WESTWOOD, A
    BULLOCK, DG
    WHITEHEAD, TP
    ANNALS OF CLINICAL BIOCHEMISTRY, 1986, 23 : 92 - 96
  • [6] Measurement uncertainty of γ-glutamyltransferase (GGT) in human serum by four approaches using different quality assessment data
    Zhou, Rui
    Qin, Yanyan
    Yin, Hongyi
    Yang, Yanmin
    Wang, Qingtao
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (02) : 242 - 248