Analysis of CT-based Navigation System for Pedicle Screw Placement

被引:20
|
作者
Hodges, Scott D. [1 ]
Eck, Jason C. [2 ]
Newton, Danette [1 ]
机构
[1] Chattanooga Outpatient Ctr, Ctr Sports Med & Orthopaed, Chattanooga, TN 37404 USA
[2] Univ Massachusetts, Dept Orthoped Surg, Worcester, MA 01605 USA
关键词
COMPUTED-TOMOGRAPHY; ACCURACY;
D O I
10.3928/01477447-20120725-23
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The incidence of pedicle screw breech varies based on anatomic location, body habitus, surgeon experience, spinal deformity, and surgical technique. Pedicle breeches have been reported to occur in up to 40% of screws. The purpose of this retrospective study was to compare the rates of revision of pedicle screw placement when using intraoperative C-arm vs O-arm (Medtronic, Memphis, Tennessee) assessment of pedicle screws. An economic analysis was also performed based on the estimated cost of pedicle screw revision. Four (1%) of 386 control patients required pedicle screw revision for a breeched pedicle screw not identified with intraoperative C-arm fluoroscopy. In the study group, none of the 331 patients returned to the operating room when O-arm was used to assess pedicle screw placement. Based on the 1% rate of returning to the operating room in the control group, the annual rate of cases nationwide requiring pedicle screw revision would be approximately 2300, with a cost of approximately $40,595,000. These results suggest that the use of intraoperative O-arm can reduce the need for revision of a breeched pedicle screw. This can potentially lead to a major cost savings.
引用
收藏
页码:E1221 / E1224
页数:4
相关论文
共 50 条
  • [1] A Comparison of CT-based Navigation Techniques for Minimally Invasive Lumbar Pedicle Screw Placement
    Wood, Martin
    Mannion, Richard
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2011, 24 (01): : E1 - E5
  • [2] Analysis of accuracy of pedicle screw placement in dysplastic pedicles in adolescent idiopathic scoliosis using the pedicle expansion technique with CT-based navigation
    Miyazaki, Masashi
    Abe, Tetsutaro
    Sako, Noriaki
    Kanezaki, Shozo
    Tsumura, Hiroshi
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2024, 29 (03) : 741 - 748
  • [3] Surgical Navigation System for Pedicle Screw Placement Based on Mixed Reality
    Seokbin Hwang
    Suk-joong Lee
    Sungmin Kim
    [J]. International Journal of Control, Automation and Systems, 2023, 21 : 3983 - 3993
  • [4] Surgical Navigation System for Pedicle Screw Placement Based on Mixed Reality
    Hwang, Seokbin
    Lee, Suk-joong
    Kim, Sungmin
    [J]. INTERNATIONAL JOURNAL OF CONTROL AUTOMATION AND SYSTEMS, 2023, 21 (12) : 3983 - 3993
  • [5] True accuracy of percutaneous pedicle screw placement in thoracic and lumbar spinal fixation with a CT-based navigation system: Intraoperative and postoperative assessment of 763 percutaneous pedicle screws
    Ouchida, Jun
    Kanemura, Tokumi
    Satake, Kotaro
    Nakashima, Hiroaki
    Segi, Naoki
    Suzuki, Kanae
    Imagama, Shiro
    [J]. JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 79 : 1 - 6
  • [6] Impact of osteosclerosis on cervical pedicle screw insertion using preoperative CT-based navigation
    Uehara, Masashi
    Ikegami, Shota
    Oba, Hiroki
    Miyaoka, Yoshinari
    Hatakenaka, Terue
    Kurogochi, Daisuke
    Fukuzawa, Takuma
    Sasao, Shinji
    Mimura, Tetsuhiko
    Takahashi, Jun
    [J]. EUROPEAN SPINE JOURNAL, 2024, 33 (06) : 2298 - 2303
  • [7] Meta-analysis of fluoroscopic and navigation-based cervical pedicle screw placement
    Soliman, Mohamed A. R.
    Khan, Asham
    Pollina, John
    Mullin, Jeffrey P.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2022, 36 (03) : 522 - 523
  • [8] A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
    Chen, Hsuan-Yu
    Xiao, Xiu-Yun
    Chen, Chih-Wei
    Chou, Hao-Kai
    Sung, Chen-Yu
    Lin, Feng Huei
    Chen, Po-Quang
    Wong, Tze-hong
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (159):
  • [9] Surgical safety of cervical pedicle screw placement with computer navigation system
    Shimokawa, Nobuyuki
    Takami, Toshihiro
    [J]. NEUROSURGICAL REVIEW, 2017, 40 (02) : 251 - 258
  • [10] Surgical safety of cervical pedicle screw placement with computer navigation system
    Nobuyuki Shimokawa
    Toshihiro Takami
    [J]. Neurosurgical Review, 2017, 40 : 251 - 258