Thermal exergy optimisation for an irreversible cogeneration power plant

被引:12
|
作者
Kaushik, S. C. [1 ]
Chandra, H. [1 ]
Khaliq, A. [2 ]
机构
[1] Indian Inst Technol Delhi, Ctr Energy Studies, New Delhi 110016, India
[2] Jamia Millia Islamia, Dept Mech Engn, New Delhi 110025, India
关键词
finite-time thermodynamics; heat engines; irreversibility parameter; irreversible cogeneration; thermal exergy optimisation;
D O I
10.1504/IJEX.2005.007254
中图分类号
O414.1 [热力学];
学科分类号
摘要
The optimal design model, based on exergy analysis, of an irreversible cogeneration cycle has been presented using finite-time thermodynamics. The external irreversibility is due to the thermal resistance between the system and the heat reservoirs while the internal irreversibility is due to the non-isentropic compression and expansion process within the system. The internal irreversibility of the irreversible cogeneration cycle is characterised by a single parameter representing the ratio of relevant entropy differences. The presence of this irreversibility parameter shows that a cogeneration power plant with internal irreversibilities delivers less exergy output and has a lower efficiency than those of the reversible and endoreversible cycles. The model presented here is of more use when compared to those obtained by earlier researchers.
引用
收藏
页码:260 / 273
页数:14
相关论文
共 50 条
  • [1] Exergy optimisation of a Brayton cycle-based cogeneration plant
    Hao, Xiaoli
    Zhang, Guoqiang
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2009, 6 (01) : 34 - 48
  • [2] Exergy optimisation of irreversible closed Brayton cycle combined cooling, heating and power plant
    Chen, L. G.
    Feng, H. J.
    Sun, F. R.
    [J]. JOURNAL OF THE ENERGY INSTITUTE, 2013, 86 (02) : 97 - 106
  • [3] EXERGY ANALYSIS AND OPTIMISATION OF A DECENTRALISED WOODCHIP-FIRED COGENERATION PLANT
    Strzalka, Rafal
    Aly, Ahmed
    Schneider, Dietrich
    Eicker, Ursula
    [J]. PAPERS OF THE 23RD EUROPEAN BIOMASS CONFERENCE: SETTING THE COURSE FOR A BIOBASED ECONOMY, 2015, : 760 - 768
  • [4] Exergy Performance Optimization of an Irreversible Closed Intercooled Regenerative Brayton Cogeneration Plant
    Bo Yang
    Lingen Chen
    Yanlin Ge
    Fengrui Sun
    [J]. Arabian Journal for Science and Engineering, 2014, 39 : 6385 - 6397
  • [5] Exergy Performance Optimization of an Irreversible Closed Intercooled Regenerative Brayton Cogeneration Plant
    Yang, Bo
    Chen, Lingen
    Ge, Yanlin
    Sun, Fengrui
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2014, 39 (08) : 6385 - 6397
  • [6] Performance optimisation of irreversible cogeneration systems based on a new exergetic performance criterion: exergy density
    Ust, Y.
    Sahin, B.
    Kodal, A.
    [J]. JOURNAL OF THE ENERGY INSTITUTE, 2009, 82 (01) : 48 - 52
  • [7] Exergy optimization for an irreversible combined cogeneration cycle
    Erdil, A
    [J]. JOURNAL OF THE ENERGY INSTITUTE, 2005, 78 (01) : 27 - 31
  • [8] A Framework of Exergy Efficiency Analysis for Cogeneration Power Plant in Cement Production
    Song, Dan
    Lin, Ling
    Bao, Wei
    [J]. JOINT INTERNATIONAL CONFERENCE ON ENERGY, ECOLOGY AND ENVIRONMENT ICEEE 2018 AND ELECTRIC AND INTELLIGENT VEHICLES ICEIV 2018, 2018,
  • [9] Exergy analysis of a circulating fluidized bed boiler cogeneration power plant
    Gurturk, Mert
    Oztop, Hakan F.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 120 : 346 - 357
  • [10] Exergy and exergoeconomic analysis of hydrogen and power cogeneration using an HTR plant
    Norouzi, Nima
    Talebi, Saeed
    Fani, Maryam
    Khajehpour, Hossein
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (08) : 2753 - 2760