Ultrasensitive, label-free detection of cardiac biomarkers with optical SIS sensor

被引:25
|
作者
Diware, Mangesh S. [1 ]
Cho, Hyun Mo [1 ]
Chegal, Won [1 ]
Cho, Yong Jai [1 ]
Kim, Dong Soo [1 ,2 ]
Won O, Sang [1 ,3 ]
Kim, Kyeong-Suk [2 ]
Paek, Se-Hwan [3 ]
机构
[1] Korea Res Inst Stand & Sci, Ctr Nanometrol, Daejeon 305340, South Korea
[2] Chosun Univ, Dept Mech Syst Engn, Gwangju 61452, South Korea
[3] Korea Univ, Dept Biomicrosyst Technol, Seoul 02841, South Korea
来源
关键词
SIS sensors; Acute myocardial infarction; Troponin I; Myoglobin; CK-MB; Ellipsometry; Biosensors; TROPONIN-I; BIOCHEMICAL MARKERS; EARLY-DIAGNOSIS; BIOSENSORS; SILICON; BREWSTER; CHOICE; DNA;
D O I
10.1016/j.bios.2016.08.049
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Acute myocardial infarction (MI) is the leading cause of high mortality and morbidity rate worldwide, early and accurate diagnosis can increase the chances of survival. In this work, we report a simple, ultrasensitive, label-free, and high-throughput solution immersed silicon (SIS) immunosensor based on non-reflection condition (NRC) for p-polarized wave for early diagnosis of MI. SIS sensor chips are just a thin dielectric polymer layer on the silicon surface, which can be functionalized for specific application. At NRC, SIS sensors are extremely sensitive to the growing thickness of a bio-layer on the sensor surface while independent of refractive index change of the surrounding medium. Therefore, SIS signal is free from thermal noise, unlike surface plasmon resonance based sensor. Also, there is no need of reference signal which facilitates fast and accurate interaction measurement. Here, SIS technology is applied to tackle two issues in MI diagnosis: high sensitivity with the direct assay and the ability to measure in human serum. Myoglobin, creatine kinase-MB, and cardiac troponin I (cTnI) proteins were used as the MI biomarkers. We were able to measure over a broad concentration range with the detection limit of 5 and 10 pg/ml for cTnl in PBS and blood serum, respectively. The response time is about 5 min. This novel technique is a suitable candidate for cost effective point-of-care application. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:242 / 248
页数:7
相关论文
共 50 条
  • [1] Capacitive biosensors for label-free and ultrasensitive detection of biomarkers
    Huang, Lei
    Zhang, Cheng
    Ye, Run
    Yan, Bin
    Zhou, Xiaojia
    Xu, Wenbo
    Guo, Jinhong
    [J]. TALANTA, 2024, 266
  • [2] Label-Free Ultrasensitive Cholesterol Detection Based on SPR Optical Fiber Sensor
    Zhang, Hongxin
    Li, Xuegang
    Zhou, Xue
    Zhang, Yanan
    [J]. IEEE Sensors Journal, 2024, 24 (24) : 40972 - 40978
  • [3] An ultrasensitive label free nanobiosensor platform for the detection of cardiac biomarkers
    Matta, Durga Prakash
    Tripathy, Suryasnata
    Vanjari, Siva Rama Krishna
    Sharma, Chandra Shekhar
    Singh, Shiv Govind
    [J]. BIOMEDICAL MICRODEVICES, 2016, 18 (06)
  • [4] An ultrasensitive label free nanobiosensor platform for the detection of cardiac biomarkers
    Durga Prakash Matta
    Suryasnata Tripathy
    Siva Rama Krishna Vanjari
    Chandra Shekhar Sharma
    Shiv Govind Singh
    [J]. Biomedical Microdevices, 2016, 18
  • [5] An Ultrasensitive Field Effect Charge Sensor for Label-free Biomolecule Detection
    Shao, Shiqian
    Wang, Yi
    [J]. 2009 LASERS & ELECTRO-OPTICS & THE PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1 AND 2, 2009, : 1270 - 1271
  • [6] Differential modulation system with potential for portable field detection: An ultrasensitive gentamicin optical sensor for label-free detection
    Sun, Dandan
    Wang, Guoquan
    Ma, Chenfei
    Liang, Lili
    Yang, Yukun
    Wang, Guanjun
    Wu, Jizhou
    Ma, Jie
    [J]. OPTICS AND LASER TECHNOLOGY, 2025, 180
  • [7] Ultrasensitive Nanoporous Interferornetric Sensor for Label-Free Detection of Gold(III) Ions
    Kumeria, Tushar
    Santos, Abel
    Losic, Dusan
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (22) : 11783 - 11790
  • [8] Label-free quantitative detection of biomarkers
    Dave, Digant P.
    Chirvi, Sajal
    [J]. IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES VIII, 2010, 7568
  • [9] Label-free DNA sensor for detection of bladder cancer biomarkers in urine
    Shin, Yong
    Perera, Agampodi Promoda
    Park, Mi Kyoung
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 200 - 206
  • [10] Tapered Optical Fiber Sensor for Label-Free Detection of Biomolecules
    Tian, Ye
    Wang, Wenhui
    Wu, Nan
    Zou, Xiaotian
    Wang, Xingwei
    [J]. SENSORS, 2011, 11 (04): : 3780 - 3790