LET Measurement Using Nuclear Emulsion and Monte Carlo Simulation for Proton Beam

被引:1
|
作者
Shin, J. [1 ]
Cho, S. [2 ]
Park, S. [1 ]
Lee, S. [3 ]
Kwak, J. [4 ]
Kim, S. [5 ]
Morishima, K. [6 ]
机构
[1] Natl Canc Ctr, Goyang, Gyeonggi Do, South Korea
[2] Natl Canc Ctr, Seoul, South Korea
[3] Natl Canc Ctr, Goyang Si, South Korea
[4] Asan Med Ctr, Asan, South Korea
[5] Pusan Natl Univ, Pusan, South Korea
[6] Nagoya Univ, Nagoya, Aichi 4648601, Japan
关键词
D O I
10.1118/1.4735297
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:3757 / 3757
页数:1
相关论文
共 50 条
  • [1] Monte Carlo simulation of a therapeutical proton beam line
    Russo, S
    Bucciolini, M
    Compagnucci, A
    Mazal, A
    Nauraye, C
    Rosenwald, JC
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 1998, 14 (02): : 63 - 71
  • [2] Monte Carlo simulations of a low energy proton beam and estimation of LET distributions
    Dahle, T. J.
    Rykkelid, A. M.
    Stokkevag, C. H.
    Gorgen, A.
    Edin, N. J.
    Malinen, E.
    Ytre-Hauge, K. S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S179 - S180
  • [3] A Monte Carlo study of different LET definitions and calculation parameters for proton beam therapy
    Smith, Edward A. K.
    Winterhalter, Carla
    Underwood, Tracy S. A.
    Aitkenhead, Adam H.
    Richardson, Jenny C.
    Merchant, Michael J.
    Kirkby, Norman F.
    Kirby, Karen J.
    Mackay, Ranald, I
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (01)
  • [4] Hypernuclear event detection in the nuclear emulsion with Monte Carlo simulation and machine learning
    Kasagi, A.
    Dou, W.
    Drozd, V.
    Ekawa, H.
    Escrig, S.
    Gao, Y.
    He, Y.
    Liu, E.
    Muneem, A.
    Nakagawa, M.
    Nakazawa, K.
    Rappold, C.
    Saito, N.
    Saito, T. R.
    Sugimoto, S.
    Taki, M.
    Tanaka, Y. K.
    Yanai, A.
    Yoshida, J.
    Yoshimoto, M.
    Wang, H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1056
  • [5] Validation and Implementation of Proton Pencil Beam Scanning Nozzle Using TOPAS Monte Carlo Simulation
    Lin, C.
    Feng, Y.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E875 - E875
  • [6] Study of proton beam spreading for a solid beam stopper double scattering method using Monte Carlo simulation
    Ju Zhi-Ping
    Cao Wu-Fei
    Liu Xiao-Wei
    [J]. ACTA PHYSICA SINICA, 2010, 59 (01) : 199 - 202
  • [7] Monte Carlo simulation of a CPO beam line: modelling the nuclear interactions
    Stankovskiy, A.
    Kerhoas-Cavata, S.
    Ferrand, R.
    Nauraye, C.
    [J]. INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, VOL 2, PROCEEDINGS, 2008, : 1387 - +
  • [8] Proton Beam Delivery to a Moving Lung Tumor and Monte Carlo Simulation with TOPAS
    Coruh, M.
    Demez, N.
    Ewell, L.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3483 - 3483
  • [9] Monte Carlo simulation of induced radioactivity for low-energy proton beam
    [J]. Wang, T. (wangtaoxtc@gmail.com), 1600, Editorial Office of High Power Laser and Particle Beams, P.O. Box 919-805, Mianyang, 621900, China (24):
  • [10] Proton beam profiling in soft biological matter by detailed Monte Carlo simulation
    Emfietzoglou, D.
    Nikjoo, H.
    Papamichael, G.
    Pathak, A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 249 : 670 - 672