Harmonic Analysis of a Photovoltaic Systems Connected to Low Voltage Grid

被引:16
|
作者
Leite, M. C. C. [1 ]
Vieira, F. A. M. [1 ]
Silva, V. B. [2 ]
Fortes, M. Z. [2 ]
Dias, D. H. N. [3 ]
机构
[1] Univ Fed Fluminense, Programa Posgrad Engn Eletr & Telecomunicacoes, Niteroi, RJ, Brazil
[2] Univ Fed Fluminense, Niteroi, RJ, Brazil
[3] Univ Fed Fluminense, Dept Engn Eletr, Niteroi, RJ, Brazil
关键词
Power Quality; Distributed Generation; Photovoltaic Systems; Harmonic Distortion; GENERATION;
D O I
10.1109/TLA.2018.8291462
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Solar Energy is clean, renewable and applicable in every place with a good solar incidence such as Brazil. The photovoltaic system is generally composed by photocells which are able to produce direct current through solar light incidence and, when connected to the grid, it needs an inverter to convert direct current in alternate current. This equipment can bring negative impact in the power quality provided from the main grid, such as voltage oscillation and harmonic distortion. In this context, this article presents an analysis of power quality using a quality analyzer on a photovoltaic system connected to the local distribution grid. All measurements were realized in a residential 3.38 kWp-photovoltaic system with an inverter. Harmonic spectrum were measured and analyzed based on the limits established in PRODIST Module 8 and IEEE 519 at the connection point of common coupling (PCC).
引用
收藏
页码:112 / 117
页数:6
相关论文
共 50 条
  • [1] Harmonic Distortion in Low Voltage Grid with Grid-Connected Photovoltaic
    Dghim, Hedi
    EL-Naggart, Ahmed
    Erlicht, Istvan
    [J]. 2018 18TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2018,
  • [2] Harmonic Distortion Analysis in a Low Voltage Grid-Connected Photovoltaic System
    Melo, F. C.
    Spaduto, R. R.
    Freitas, L. C. G.
    Tavares, C. E.
    Macedo, J. R., Jr.
    Rezende, P. H. O.
    [J]. IEEE LATIN AMERICA TRANSACTIONS, 2015, 13 (01) : 136 - 142
  • [3] Harmonic Impact of Grid Connected Photovoltaic system on Low Voltage Power system
    Agrawal, Amit
    Singh, Dharmendra Kumar
    [J]. 2018 3RD INTERNATIONAL CONFERENCE FOR CONVERGENCE IN TECHNOLOGY (I2CT), 2018,
  • [4] Harmonic Analysis of Grid Connected Power Electronic Systems in Low Voltage Distribution Networks
    Kumar, Dinesh
    Zare, Firuz
    [J]. IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2016, 4 (01) : 70 - 79
  • [5] Analysis of Grid-Connected Photovoltaic Generation Systems in the Harmonic Domain
    Diaz-Araujo, Marcolino Humberto
    Medina-Rios, Aurelio
    Madrigal-Martinez, Manuel
    Cleary-Balderas, Luis Arthur
    [J]. ENERGIES, 2019, 12 (24)
  • [6] Analysis and Suppression of Harmonic Resonance in Photovoltaic Grid-Connected Systems
    Zhu, Tong
    Huang, Gechao
    Ouyang, Xuetong
    Zhang, Weilin
    Wang, Yanfeng
    Ye, Xi
    Wang, Yuhong
    Gao, Shilin
    [J]. ENERGIES, 2024, 17 (05)
  • [7] Harmonic impact of decentralized photovoltaic systems and limitation of photovoltaic capacity in low voltage grid
    Bao, Han
    Ying, Shaoqing
    Schwarz, Harald
    [J]. 2014 14TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2014, : 1 - 4
  • [8] Voltage Stability and Sensitivity Analysis of Grid-Connected Photovoltaic Systems
    Xue, Yaosuo
    Manjrekar, Madhav
    Lin, Chenxi
    Tamayo, Maria
    Jiang, John N.
    [J]. 2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [9] Voltage control design for grid connected photovoltaic systems
    Ionescu, Mihai Andrei
    [J]. PROCEEDINGS OF THE 2018 10TH INTERNATIONAL CONFERENCE ON ELECTRONICS, COMPUTERS AND ARTIFICIAL INTELLIGENCE (ECAI), 2018,
  • [10] Long-Term Harmonic Analysis of Grid-Connected Photovoltaic Systems
    Scekic, Lazar
    Mujovic, Sasa
    [J]. 2022 20TH INTERNATIONAL CONFERENCE ON HARMONICS & QUALITY OF POWER (ICHQP 2022), 2022,