Development and validation of an LC-MS/MS method for determination of compound K in human plasma and clinical application

被引:23
|
作者
Kim, Jung Soo [1 ,2 ,3 ]
Kim, Yunjeong [1 ,4 ]
Han, Song-Hee [1 ,4 ]
Jeon, Ji-Young [1 ,4 ]
Hwang, Minho [1 ,4 ]
Im, Yong-Jin [1 ,4 ]
Kim, Jung Hyun [1 ,5 ]
Lee, Sun Young [1 ,6 ]
Chae, Soo-Wan [1 ,4 ,7 ]
Kim, Min-Gul [1 ,3 ,4 ]
机构
[1] Chonbuk Natl Univ Hosp, Biomed Res Inst, Jeonju 561712, South Korea
[2] Chonbuk Natl Univ, Sch Med, Dept Pediat, Jeonju 561180, South Korea
[3] Chonbuk Natl Univ, Res Inst Clin Med, Jeonju 561712, South Korea
[4] Chonbuk Natl Univ Hosp, Clin Trial Ctr, Jeonju 561712, South Korea
[5] Chonbuk Natl Univ, Sch Med, Dept Med Nutr Therapy, Jeonju 561180, South Korea
[6] Chonbuk Natl Univ Hosp, Dept Radiat Oncol, Jeonju 561712, South Korea
[7] Chonbuk Natl Univ, Dept Pharmacol, Sch Med, Jeonju 561180, South Korea
关键词
Panax ginseng; Compound K; Fermented Korean red ginseng; LC-MS/MS; Pharmacokinetics;
D O I
10.5142/jgr.2013.37.135
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
A rapid, sensitive and selective analytical method was developed and validated for the determination of compound K, a major intestinal bacterial metabolite of ginsenosides in human plasma. Liquid-liquid extraction was used for sample preparation and analysis, followed by liquid chromatography tandem spectrometric analysis and an electrospray-ionization interface. Compound K was analyzed on a Phenomenex Luna C18 column (100x2.00 mm, 3 mu m) with the mobile phase run isocratically with 10 mM ammonium acetate-methanol-acetonitrile (5:47.5:47.5, v/v/v) at a flow rate of 0.5 mL/min The method was validated for accuracy (relative error <12.63%), precision (coefficient of variation <9.14%), linearity, and recovery. The assay was linear over the entire range of calibration standards i.e., a concentration range of 1 ng/mL to 1,000 ng/mL (r(2) >0.9968). The recoveries of compound K after liquid-liquid extraction at 1, 2, 400, and 800 ng/mL were 106.00 +/- 0.08%, 103.50 +/- 0.19%, 111.45 +/- 5.21%, and 89.62 +/- 34.46% for intra-day and 85.40 +/- 0.08%, 94.50 +/- 0.09%, 112.50 +/- 5.21%, and 95.87 +/- 34.46% for inter-day, respectively. The lower limit of quantification of the analytical method of compound K was 1 ng/mL in human plasma. The developed method was successfully applied to a pharmacokinetic study of compound K after oral administration in ten of healthy human subjects.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 50 条
  • [1] Determination of plasma concentration of Belimumab by LC-MS/MS: Method development, validation, and clinical application
    Marin, Clemence
    Noe, Gaelle
    Schlemmer, Dimitri
    Beaulieu, Quentin
    Robidou, Pascal
    Mansour, Bochra
    Hirtz, Christophe
    Vialaret, Jerome
    Antignac, Marie
    Moyon, Quentin
    Benameur, Neila
    Amoura, Zahir
    Zahr, Noel
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 236
  • [2] Development and validation of a LC-MS/MS method for determination of bivalirudin in human plasma: Application to a clinical pharmacokinetic study
    Pan, Guixiang
    Wang, Xiaoming
    Huang, Yuhong
    Gao, Xiumei
    Wang, Yuefei
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (01) : 105 - 109
  • [3] LC-MS/MS Method Development and Validation for the Determination of Nifedipine in Human Plasma
    Logoyda, Liliya S.
    [J]. BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2020, 10 (05): : 6220 - 6227
  • [4] Development and validation of a LC-MS/MS method for the determination of viaminate in human plasma
    Yin, Jing
    Ni, Kun-Yi
    Shen, Yue
    Ma, Peng-Cheng
    Cao, Ling
    Wang, Wei-Peng
    Wang, Yu
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2): : 376 - 380
  • [5] Determination of olverembatinib in human plasma and cerebrospinal fluid by an LC-MS/MS method: Validation and clinical application
    Xiang, Dong
    Zhao, Tinghui
    Wang, Jue
    Cao, Yang
    Yu, Qiuxia
    Liu, Lu
    Yu, Hengyi
    Li, Xiping
    Li, Ninghong
    Yi, Yang
    Gong, Xuepeng
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 230
  • [6] Development and Validation of New LC-MS/MS Method for the Determination of armodafinil in Human Plasma
    Ramesh, Devi
    Ramakrishna, Singirikonda
    Habibuddin, Mohammad
    [J]. CURRENT PHARMACEUTICAL ANALYSIS, 2012, 8 (03) : 295 - 305
  • [7] Development and validation of LC-MS/MS method for determination of plasma apixaban
    Dzudovic, Jelena
    Sakac, Milkica Crevar
    Antunovic, Marko
    Repic, Aleksandra
    Obradovic, Slobodan
    Djordjevic, Snezana
    Savic, Jelena
    Dzudovic, Boris
    [J]. ACTA CHROMATOGRAPHICA, 2022, 34 (03) : 332 - 337
  • [8] Development and Validation of a Sensitive LC-MS/MS Method for Determination of Valacyclovir in Human Plasma: Application to a Bioequivalence Study
    Konda, R. K.
    Chandu, B. R.
    Challa, B. R.
    Chandrasekhar, K. B.
    [J]. ACTA CHROMATOGRAPHICA, 2013, 25 (04) : 669 - 686
  • [9] Development and validation of an LC-MS/MS method for the determination of tolvaptan in human plasma and its application to a pharmacokinetic study
    Pei, Qi
    Zhang, Bikui
    Tan, Hongyi
    Liu, Lihua
    Peng, Xiangdong
    Li, Zuojun
    Huang, Panhao
    Luo, Mi
    Zuo, Xiaocong
    Guo, Chengxian
    Yang, Guoping
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 913 : 84 - 89
  • [10] Development and Validation of LC-MS/MS Method for Determination of Ondansetron in rat Plasma and its Application
    Pang, Lingxia
    Wang, Qing
    Wang, Youpei
    Zheng, Meiqin
    Wu, Haiya
    Wang, Zhiyi
    [J]. LATIN AMERICAN JOURNAL OF PHARMACY, 2012, 31 (02): : 305 - 309