Carboxyl modified magnetic nanoparticles coated open tubular column for capillary electrochromatographic separation of biomolecules

被引:33
|
作者
Wang, Wentao
Xiao, Xing
Chen, Jia
Jia, Li [1 ]
机构
[1] S China Normal Univ, Minist Educ, Key Lab Laser Life Sci, Guangzhou 510631, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Carboxyl modified magnetic nanoparticles; Open tubular capillary electrochromatography; Biomolecules; Separation; TENTACLE-TYPE POLYMER; STATIONARY-PHASE; GRAPHENE OXIDE; PROTEIN SEPARATION; ELECTROPHORETIC SEPARATION; ZONE-ELECTROPHORESIS; HIGHLY EFFICIENT; POROUS LAYER; EGG-WHITE; PEPTIDES;
D O I
10.1016/j.chroma.2015.07.111
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Carboxyl modified magnetic nanoparticles (Fe3O4-COOH MNPs) coated open tubular (OT) columns were prepared for capillary electrochromatography. The Fe3O4-COOH MNPs coatings were constructed on the surface of positively charged poly(diallydimethylammonium chloride) (PDDA) modified capillaries through electrostatic self-assembly approach. The as-prepared PDDA@Fe3O4-COOH MNPs coated OT columns were characterized by scanning electron microscopy and electroosmotic flow measurement. The electrochromatographic characterization of the OT columns was evaluated by separation of amino acids, dipeptides and proteins. The influences of background solution pH, concentration, and organic modifier content on separation were investigated. The separation of these analytes was primarily based on the electrophoretic mechanism in combination with chromatographic mechanism. The Fe3O4-COOH MNPs coatings improved the separation resolution of these analytes due to their large surface area. Three variants of bovine serum albumin, two variants of P-lactoglobulin and nine glycoisoforms of ovalbumin were successfully separated. The relative standard deviations of migration times of analytes representing run-to-run, day-to-day and column-to-column were less than 4.3%. Furthermore, the feasibility of the PDDA@Fe3O4-COOH MNPs coated OT column was verified by successful separation of acidic proteins in egg white. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 100
页数:9
相关论文
共 50 条
  • [1] Preparation of β-cyclodextrin-gold nanoparticles modified open tubular column for capillary electrochromatographic separation of chiral drugs
    Zhou, Li
    Jiang, Shenmeng
    Zhang, Xue
    Fang, Linlin
    Guo, Xingjie
    ELECTROPHORESIS, 2018, 39 (07) : 941 - 947
  • [2] Capillary electrochromatographic separation of proteins on a column coated with titanium dioxide nanoparticles
    Hsieh, Yi-Ling
    Chen, Tse-Hsien
    Liu, Chuen-Ying
    ELECTROPHORESIS, 2006, 27 (21) : 4288 - 4294
  • [3] Titanium dioxide nanoparticles-coated column for capillary electrochromatographic separation of oligopeptides
    Hsieh, YL
    Chen, TH
    Liu, CP
    Liu, CY
    ELECTROPHORESIS, 2005, 26 (21) : 4089 - 4097
  • [4] Polydopamine-coated open tubular column for the separation of proteins by capillary electrochromatography
    Xiao, Xing
    Wang, Wentao
    Chen, Jia
    Jia, Li
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (16) : 2893 - 2899
  • [5] Evaluation of Temperature-Responsive Open Tubular Capillary Electrochromatographic Column Modified with Poly(N-isopropylacrylamide)
    Liu, Zongjian
    Geng, Fangfang
    Ha, Xuefeng
    Feng, Yusi
    Che, Baoquan
    Wu, Kechun
    Li, Yujuan
    Dai, Rongji
    Zhang, Yukui
    Deng, Yulin
    CHROMATOGRAPHIA, 2013, 76 (3-4) : 201 - 206
  • [6] Evaluation of Temperature-Responsive Open Tubular Capillary Electrochromatographic Column Modified with Poly(N-isopropylacrylamide)
    Zongjian Liu
    Fangfang Geng
    Xuefeng Ha
    Yusi Feng
    Baoquan Che
    Kechun Wu
    Yujuan Li
    Rongji Dai
    Yukui Zhang
    Yulin Deng
    Chromatographia, 2013, 76 : 201 - 206
  • [7] Zirconia nanoparticles-coated column for the capillary electrochromatographic separation of iron-binding- and phosphorylated-proteins
    Lee, Chia-Hsin
    Huang, Bao-Yu
    Chen, Yu-Cheng
    Liu, Ching-Piao
    Liu, Chuen-Ying
    ANALYST, 2011, 136 (07) : 1481 - 1487
  • [8] Proline-coated column for the capillary electrochromatographic separation of amino acids by in-column derivatization
    Lin, CC
    Liu, CY
    ELECTROPHORESIS, 2004, 25 (18-19) : 3216 - 3223
  • [9] Cyclodextrin modified gold nanoparticles-based open-tubular capillary electrochromatographic separations of polyaromatic hydrocarbons
    Pavel Řezanka
    Klára Navrátilová
    Pavel Žvátora
    David Sýkora
    Pavel Matějka
    Ivan Mikšík
    Václav Kašička
    Vladimír Král
    Journal of Nanoparticle Research, 2011, 13 : 5947 - 5957
  • [10] Cyclodextrin modified gold nanoparticles-based open-tubular capillary electrochromatographic separations of polyaromatic hydrocarbons
    Rezanka, Pavel
    Navratilova, Klara
    Zvatora, Pavel
    Sykora, David
    Matejka, Pavel
    Miksik, Ivan
    Kasicka, Vaclav
    Kral, Vladimir
    JOURNAL OF NANOPARTICLE RESEARCH, 2011, 13 (11) : 5947 - 5957