Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM)

被引:71
|
作者
Agostini, Denis [1 ,2 ]
Marie, Pierre-Yves [3 ,4 ,5 ]
Ben-Haim, Simona [6 ,7 ]
Rouzet, Francois [8 ,9 ,10 ]
Songy, Bernard [11 ]
Giordano, Alessandro [12 ]
Gimelli, Alessia [13 ]
Hyafil, Fabien [14 ,15 ]
Sciagra, Roberto [16 ]
Bucerius, Jan [17 ,18 ,19 ]
Verberne, Hein J. [20 ]
Slart, Riemer H. J. A. [21 ,22 ]
Lindner, Oliver [23 ]
机构
[1] CHU Caen, Dept Nucl Med, Caen, France
[2] Normandy Univ, EA 4650, Caen, France
[3] Univ Lorraine, Nancyclotep Expt Imaging Platform, Fac Med, INSERM,U1116, F-54000 Nancy, France
[4] Univ Lorraine, CHU Nancy, Dept Nucl Med, Fac Med,INSERM,U1116, F-54000 Nancy, France
[5] Univ Lorraine, Fac Med, INSERM, U1116, F-54000 Nancy, France
[6] UCL, Inst Nucl Med, Univ Coll Hosp, London, England
[7] Chaim Sheba Med Ctr, Dept Nucl Med, Ramat Gan, Israel
[8] Univ Hosp Paris Bichat, Dept Nucl Med, INSERM, UMR 1148, Paris, France
[9] Paris Diderot Paris 7 Univ Paris, Paris, France
[10] INSERM, UMR 1148, Paris, France
[11] Ctr Cardiol Nord, St Denis, France
[12] Univ Cattolica Sacro Cuore, Dept Bioimages & Radiol Sci, Inst Nucl Med, Rome, Italy
[13] Fdn Toscana Gabriele Monasterio, Pisa, Italy
[14] Hop Xavier Bichat, Assistance Publ Hop Paris, Dept Nucl Med, Inserm,UMR 1148, Paris, France
[15] Paris Diderot Paris 7 Univ, Paris, France
[16] Univ Florence, Nucl Med Unit, Dept Expt & Clin Biomed Sci, Florence, Italy
[17] Maastricht Univ, Med Ctr, Dept Nucl Med, Maastricht, Netherlands
[18] Maastricht Univ, Med Ctr, Cardiovasc Res Inst Maastricht CARIM, Maastricht, Netherlands
[19] Univ Hosp RWTH Aachen, Dept Nucl Med, Aachen, Germany
[20] Acad Med Ctr, Dept Nucl Med, Amsterdam, Netherlands
[21] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[22] Univ Twente, Fac Sci & Technol, Dept Biomed Photon Imaging, Enschede, Netherlands
[23] Heart & Diabet Ctr NRW, Inst Radiol Nucl Med & Mol Imaging, Bad Oeynhausen, Germany
关键词
Perfusion; CZT camera; Coronary artery disease; Diagnosis; Prognosis; MYOCARDIAL-PERFUSION SPECT; EMISSION COMPUTED-TOMOGRAPHY; CZT CAMERA; HIGH-SPEED; MAGNETIC-RESONANCE; PROGNOSTIC VALUE; COMBINED SUPINE; ANGER CAMERA; HUMAN IMAGES; GATED SPECT;
D O I
10.1007/s00259-016-3467-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The trade-off between resolution and count sensitivity dominates the performance of standard gamma cameras and dictates the need for relatively high doses of radioactivity of the used radiopharmaceuticals in order to limit image acquisition duration. The introduction of cadmium-zinc-telluride (CZT)-based cameras may overcome some of the limitations against conventional gamma cameras. CZT cameras used for the evaluation of myocardial perfusion have been shown to have a higher count sensitivity compared to conventional single photon emission computed tomography (SPECT) techniques. CZT image quality is further improved by the development of a dedicated three-dimensional iterative reconstruction algorithm, based on maximum likelihood expectation maximization (MLEM), which corrects for the loss in spatial resolution due to line response function of the collimator. All these innovations significantly reduce imaging time and result in a lower patient's radiation exposure compared with standard SPECT. To guide current and possible future users of the CZT technique for myocardial perfusion imaging, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, has decided to examine the current literature regarding procedures and clinical data on CZT cameras. The committee hereby aims 1) to identify the main acquisitions protocols; 2) to evaluate the diagnostic and prognostic value of CZT derived myocardial perfusion, and finally 3) to determine the impact of CZT on radiation exposure.
引用
收藏
页码:2423 / 2432
页数:10
相关论文
共 39 条
  • [1] Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM)
    Denis Agostini
    Pierre-Yves Marie
    Simona Ben-Haim
    François Rouzet
    Bernard Songy
    Alessandro Giordano
    Alessia Gimelli
    Fabien Hyafil
    Roberto Sciagrà
    Jan Bucerius
    Hein J. Verberne
    Riemer H. J. A. Slart
    Oliver Lindner
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2016, 43 : 2423 - 2432
  • [2] Erratum to: Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM)
    Denis Agostini
    Pierre-Yves Marie
    Simona Ben-Haim
    François Rouzet
    Bernard Songy
    Alessandro Giordano
    Alessia Gimelli
    Fabien Hyafil
    Roberto Sciagrà
    Jan Bucerius
    Hein J. Verberne
    Riemer H. J. A. Slart
    Oliver Lindner
    Christopher Übleis
    Marcus Hacker
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2017, 44 : 176 - 176
  • [3] Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM) (vol 43, pg 2423, 2016)
    Agostini, Denis
    Marie, Pierre-Yves
    Ben-Haim, Simona
    Rouzet, Francois
    Songy, Bernard
    Giordano, Alessandro
    Gimelli, Alessia
    Hyafil, Fabien
    Sciagra, Roberto
    Bucerius, Jan
    Verberne, Hein J.
    Slart, Riemer H. J. A.
    Lindner, Oliver
    Uebleis, Christopher
    Hacker, Marcus
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 (01) : 176 - 176
  • [4] Comparison of conventional and cadmium-zinc-telluride SPECT camera in women with suspected coronary artery disease
    Mannarino, T.
    Assante, R.
    Acampa, W.
    Zampella, E.
    Genova, A.
    Cantoni, V.
    Green, R.
    Nappi, C.
    Gaudieri, V.
    Petretta, M.
    Cuocolo, A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S375 - S375
  • [5] Diagnostic performance of different cardiac stress protocols for myocardial perfusion imaging for the diagnosis of coronary artery disease using a cadmium-zinc-telluride camera with invasive coronary angiography correlation
    Ochoa-Figueroa, M.
    Frias-Rose, J.
    Good, E.
    Sanchez-Rodriguez, V.
    Davidsson, A.
    Pagonis, C.
    [J]. REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2023, 42 (05): : 281 - 288
  • [6] Position paper of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM) on PET imaging of atherosclerosis
    Jan Bucerius
    Fabien Hyafil
    Hein J. Verberne
    Riemer H. J. A. Slart
    Oliver Lindner
    Roberto Sciagra
    Denis Agostini
    Christopher Übleis
    Alessia Gimelli
    Marcus Hacker
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2016, 43 : 780 - 792
  • [7] Prognostic Value of Myocardial Perfusion Imaging with a Cadmium-Zinc-Telluride SPECT Camera in Patients Suspected of Having Coronary Artery Disease
    Engbers, Elsemiek M.
    Timmer, Jorik R.
    Mouden, Mohamed
    Knollema, Siert
    Jager, Pieter L.
    Ottervanger, Jan Paul
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (09) : 1459 - 1463
  • [8] Position paper of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM) on PET imaging of atherosclerosis
    Bucerius, Jan
    Hyafil, Fabien
    Verberne, Hein J.
    Slart, Riemer H. J. A.
    Lindner, Oliver
    Sciagra, Roberto
    Agostini, Denis
    Uebleis, Christopher
    Gimelli, Alessia
    Hacker, Marcus
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (04) : 780 - 792
  • [9] Strategies for radiation dose reduction in nuclear cardiology and cardiac computed tomography imaging: a report from the European Association of Cardiovascular Imaging (EACVI), the Cardiovascular Committee of European Association of Nuclear Medicine (EANM), and the European Society of Cardiovascular Radiology (ESCR)
    Gimelli, Alessia
    Achenbach, Stephan
    Buechel, Ronny R.
    Edvardsen, Thor
    Francone, Marco
    Gaemperli, Oliver
    Hacker, Marcus
    Hyafil, Fabien
    Kaufmann, Philipp A.
    Lancellotti, Patrizio
    Nieman, Koen
    Pontone, Gianluca
    Pugliese, Francesca
    Verberne, Hein J.
    Gutberlet, Matthias
    Bax, Jeroen J.
    Neglia, Danilo
    [J]. EUROPEAN HEART JOURNAL, 2018, 39 (04) : 286 - 294
  • [10] Accuracy of cadmium-zinc-telluride imaging in detecting single and multivessel coronary artery disease: Is there any gender difference?
    Gimelli, Alessia
    Pugliese, Nicola Riccardo
    Kusch, Annette
    Giorgetti, Assuero
    Marzullo, Paolo
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 274 : 388 - 393