Time weighted average concentrations measured with Diffusive Gradients in Thin films (DGT)

被引:18
|
作者
Altier, Alexandra [1 ,2 ]
Jimenez-Piedrahita, Martin [1 ,2 ]
Uribe, Ramiro [3 ]
Rey-Castro, Carlos [1 ,2 ]
Galceran, Josep [1 ,2 ]
Puy, Jaume [1 ,2 ]
机构
[1] Univ Lleida, Dept Quim, Rovira Roure 191, Lleida 25198, Catalonia, Spain
[2] AGROTECNIO, Rovira Roure 191, Lleida 25198, Catalonia, Spain
[3] Univ Tolima, Dept Phys, Ibague 730006, Colombia
关键词
Passive sampling; Concentration fluctuation; Time average concentration; Lability degree; Transient effects; Complexation; IN-SITU MEASUREMENT; ORGANIC CONTAMINANTS; AQUATIC COLLOIDS; PASSIVE SAMPLER; TRACE-METALS; KEY ROLE; SPECIATION; COMPLEXES; BIOAVAILABILITY; ACCUMULATION;
D O I
10.1016/j.aca.2019.01.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Time weighted average (TWA) concentrations can improve the assessment of water quality. DGT (Diffusive Gradients in Thin films) devices have been suggested as simple tools to measure TWA metal concentrations, but the connection of TWA with C-DGT has not been rigorously discussed. It is shown here that C-DGT is the average DGT-labile concentration along the deployment, which suggests that it is well suited to correlate with toxicity effects. In terms of real species, C-DGT is a good estimator of the TWA concentration for simple metal solutions (no ligands are present) when the accumulation takes place under perfect sink conditions. Differences between CDGT and the TWA concentration for short pulses (<40 min), when the transient regime becomes relevant, are reported. In the presence of complexes, C-DGT contains the TWA of the product of the labile fraction times the diffusivity of the complex (relative to that of the free metal). This means that C-DGT can underestimate the TWA of the total metal concentration due to the presence of complexes less mobile than the free metal or not fully labile. These findings are illustrated with Cd, Ni, Mg or Ni + nitrilotriacetic acid (NTA) solutions. When only one complex is relevant, as in the Ni + NTA system, a simple correction factor can yield the TWA concentration from C-DGT. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:114 / 124
页数:11
相关论文
共 50 条
  • [1] Development of a miniaturized diffusive gradients in thin films (DGT) device
    Alexa, Nadia
    Zhang, Hao
    Lead, Jamie R.
    ANALYTICA CHIMICA ACTA, 2009, 655 (1-2) : 80 - 85
  • [2] Use of diffusive gradients in thin films (DGT) in undisturbed field soils
    Nowack, B
    Koehler, S
    Schulin, R
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (04) : 1133 - 1138
  • [3] Assessing the bioavailability of antibiotics in soil with the diffusive gradients in thin films (DGT)
    Song, Mengke
    Su, Yicheng
    Jiang, Longfei
    Peng, Ke
    Li, Jinling
    Liu, Sisi
    Sun, Yingtao
    Chen, Chang-Er
    Luo, Chunling
    JOURNAL OF HAZARDOUS MATERIALS, 2023, 448
  • [4] Estimation of diffusive boundary layer thickness in studies involving diffusive gradients in thin films (DGT)
    Ø. A. Garmo
    K. Razi Naqvi
    O. Røyset
    E. Steinnes
    Analytical and Bioanalytical Chemistry, 2006, 386 : 2233 - 2237
  • [5] Estimation of diffusive boundary layer thickness in studies involving diffusive gradients in thin films (DGT)
    Garmo, O. A.
    Naqvi, K. Razi
    Royset, O.
    Steinnes, E.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (7-8) : 2233 - 2237
  • [6] New holder configurations for use in the diffusive gradients in thin films (DGT) technique
    Ding, Shiming
    Wang, Yan
    Zhang, Liping
    Xu, Lv
    Gong, Mengdan
    Zhang, Chaosheng
    RSC ADVANCES, 2016, 6 (91): : 88143 - 88156
  • [7] Progress in understanding the use of diffusive gradients in thin films (DGT) - back to basics
    Davison, William
    Zhang, Hao
    ENVIRONMENTAL CHEMISTRY, 2012, 9 (01) : 1 - 13
  • [8] The effects of phosphorus addition on phytoavailability of zinc by diffusive gradients in thin films (DGT)
    Sonmez, Osman
    Pierzynski, Gary
    Kaya, Cengiz
    Aydemir, Salih
    TURKISH JOURNAL OF AGRICULTURE AND FORESTRY, 2016, 40 (03) : 379 - 385
  • [9] Performance characteristics for the measurement of Cs and Sr by diffusive gradients in thin films (DGT)
    Chang, LY
    Davison, W
    Zhang, H
    Kelly, M
    ANALYTICA CHIMICA ACTA, 1998, 368 (03) : 243 - 253
  • [10] Determination of arsenic species using the Diffusive Gradients in Thin films (DGT) device
    Fontanella, M. C.
    Beone, G. M.
    Cattani, I.
    UNDERSTANDING THE GEOLOGICAL AND MEDICAL INTERFACE OF ARSENIC, AS 2012, 2012, : 402 - 403