Substation Lightning Performance Estimation Due to Strikes Into Connected Overhead Lines

被引:13
|
作者
Savic, Milan S. [1 ]
Savic, Ana M. [2 ]
机构
[1] Univ Belgrade, Fac Elect Engn, Beograd 11000, Serbia
[2] Sch Elect Engn & Comp Sci Appl Studies, Beograd 11000, Serbia
关键词
Insulation coordination; lightning protection; power system transients; TRANSMISSION-LINES; PROBABILISTIC EVALUATION; FAILURE; SYSTEM; RATES; EMTP;
D O I
10.1109/TPWRD.2015.2404771
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The generalization of the probabilistic lightning limiting parameter (LLP) method for high-voltage substation lightning performance estimation due to the discharges into connected overhead lines (OHLs) is described. The method improvement is made only for the case of lightning strokes to the shield wire of OHL, causing back-flashover in front of the substation. The improved LLP method is illustrated at the insulation coordination study of the 400-kV line with long connecting cable with direct entry into the gas-insulated substation of the hydroelectric plant. The number of surge arrester sets and sensitivity analyses of the number of connected step-up transformers influence to the mean time between failures of the 400-kV transformer and equipment insulation are investigated.
引用
收藏
页码:1752 / 1760
页数:9
相关论文
共 50 条
  • [1] Evaluation of Lightning Attachment and Coupling Models for the Estimation of the Lightning Performance of Overhead Distribution Lines
    Mikropoulos, Pantelis N.
    Tsovilis, Thomas E.
    Pori, Aikaterini S.
    [J]. 2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1212 - 1216
  • [2] Research on Differentiated Lightning Protection of Overhead Distribution Lines under Continuous Lightning Strikes
    Li, Duanjiao
    Sun, Wenxing
    Song, Kunyu
    Zhu, Ruifeng
    Zhong, Zhenxin
    Ding, Tongshu
    Gao, Jiachen
    [J]. ENERGIES, 2024, 17 (18)
  • [3] Estimation of the Influence of Direct strokes on the Lightning Performance of Overhead Distribution Lines
    Tossani, F.
    Napolitano, F.
    Borghetti, A.
    Nucci, C. A.
    Lopes, G. P.
    Martinez, M. L. B.
    dos Santos, G. J. G.
    [J]. 2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [4] Lightning strikes: danger overhead
    Ten Duis, HJ
    [J]. BRITISH JOURNAL OF SPORTS MEDICINE, 1998, 32 (04) : 276 - 278
  • [5] LIGHTNING PERFORMANCE OF OVERHEAD LINES.
    Chisholm, W.A.
    Buchan, P.G.
    [J]. Research Review - Ontario Hydro, 1981, (03): : 19 - 24
  • [6] Estimation of Lightning Incidence to Overhead Transmission Lines
    Mikropoulos, Pantelis N.
    Tsovilis, Thomas E.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (03) : 1855 - 1865
  • [7] An accurate approach for the evaluation of the performance of overhead distribution lines due to indirect lightning
    Andreotti, Amedeo
    Araneo, Rodolfo
    Mahmood, Farhan
    Pierno, Antonio
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2020, 186
  • [8] Some aspects of overhead transmission lines lightning performance estimation in engineering practice
    Banjanin, Mladen S.
    Savic, Milan S.
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2016, 26 (01): : 79 - 93
  • [9] Flashover rate due lightning in overhead distribution lines
    Vasquez, Carmen
    Osal, William
    Blanco, Carolina
    [J]. PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON ELECTRICAL POWER QUALITY AND UTILISATION, VOLS 1 AND 2, 2007, : 834 - 837
  • [10] Lightning surges in hybrid cable-overhead lines: Part II—voltage estimation for strikes to shield wire
    F. Faria da Silva
    Kasper Pedersen