Patent Foramen Ovale Closure With the Gore Septal Occluder: Initial UK Experience

被引:11
|
作者
Thomson, John D. [1 ]
Hildick-Smith, David [2 ]
Clift, Paul [3 ]
Morgan, Gareth [4 ]
Daniels, Matthew [5 ,6 ]
Henderson, Robert [7 ]
Spence, Mark S. [8 ]
Mahadevan, Vaikom S. [9 ]
Crossland, David [10 ]
Ormerod, Oliver [5 ]
机构
[1] Leeds Gen Infirm, Dept Congenital Cardiol, Leeds LS1 3EX, W Yorkshire, England
[2] Sussex Cardiac Ctr, Dept Cardiol, Brighton, E Sussex, England
[3] Queen Elizabeth Hosp, Dept Adult Congenital Heart Dis, Birmingham B15 2TH, W Midlands, England
[4] Bristol Heart Inst, Dept Congenital Cardiol, Bristol, Avon, England
[5] John Radcliffe Hosp, Dept Cardiovasc Med, Oxford OX3 9DU, England
[6] Univ Oxford, Radcliffe Dept Med, Div Cardiovasc Med, Oxford, England
[7] Univ Nottingham Hosp, Trent Cardiac Ctr, Dept Cardiol, Nottingham NG7 2UH, England
[8] Royal Victoria Hosp, Dept Cardiol, Belfast BT12 6BA, Antrim, North Ireland
[9] Manchester Royal Infirm, Dept Cardiol, Manchester M13 9WL, Lancs, England
[10] Freeman Rd Hosp, Dept Paediat Cardiol, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
基金
英国惠康基金;
关键词
patent foramen ovale; atrial septal defect; congenital heart; disease in adults; cerebrovascular accident; TRANSCATHETER CLOSURE; ATRIAL-FIBRILLATION; CRYPTOGENIC STROKE; PERCUTANEOUS CLOSURE; DEVICES; PFO;
D O I
10.1002/ccd.25063
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesTo report procedural outcome and short-term follow-up data for the Gore septal occluder (GSO), a new device for closure of patent foramen ovale (PFO). BackgroundTranscatheter closure of PFO is an established treatment modality but no current device provides a perfect solution. The GSO has a number of design features, which make it potentially attractive for closure of defects in the atrial septum. MethodsData from 9 centers in the United Kingdom implanting the GSO device, submitted to an electronic registry for evaluation. ResultsTwo hundred twenty-nine patients undergoing PFO closure from June 2011 to October 2012 were included. Indications for closure were secondary prevention of paradoxical cerebral emboli (83.4%), migraine (2.1%), platypnoea orthodeoxia (3.9%), and other (10.5%). Median PFO size was 8 mm and 34 and 39%, respectively, had long tunnel anatomy or atrial septal aneurysms. A GSO was successfully implanted in all cases. A single device was used in 98% but in 4 patients the initial device was removed and a second device required. Procedural complications occurred in 3% and later complications (e.g., atrial fibrillation, atrial ectopics, and device thrombus) in 5.7% of cases. All patients have undergone clinical and echocardiographic follow-up and all devices remain in position. Early bubble studies (median 0 months) with Valsalva maneuver in 67.2% were negative in 89%. ConclusionsThe GSO is an effective occlusion device for closure of PFO of all types. Longer-term follow-up particularly to document later closure rates are required. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:467 / 473
页数:7
相关论文
共 50 条
  • [1] Results of Percutaneous Closure of Patent Foramen Ovale With the GORE® Septal Occluder
    Knerr, Meike
    Bertog, Stefan
    Vaskelyte, Laura
    Hofmann, Ilona
    Sievert, Horst
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (07) : 1144 - 1151
  • [2] Initial clinical experience with the GORE septal occluder for the treatment of atrial septal defects and patent foramen ovale
    Freixa, Xavier
    Ibrahim, Reda
    Chan, Jason
    Garceau, Patrick
    Dore, Annie
    Marcotte, Francois
    Mercier, Lise-Andree
    Mongeon, Francois-Pierre
    Basmadjian, Arsene
    Khairy, Paul
    Asgar, Anita W.
    EUROINTERVENTION, 2013, 9 (05) : 629 - 635
  • [3] Initial use of the new GORE® septal occluder in patent foramen ovale closure: Implantation and preliminary results
    MacDonald, Simon T.
    Daniels, Matthew J.
    Ormerod, Oliver J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (04) : 660 - 665
  • [4] Thrombus in a Hypercoagulable Patient Following Patent Foramen Ovale Closure With the Gore Septal Occluder
    Luc, Jessica G. Y.
    Bakar, Shahrukh N.
    Kiaii, Bob
    Sridhar, Kumar
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (11) : 1108 - 1109
  • [5] Clinical Performance of the New Gore Septal Occluder in Patent Foramen Ovale Closure: A Single-Center Experience
    Sganzerla, Paolo
    Rondi, Mauro
    Pavone, Andrea
    Aiolfi, Eleonora
    Facchinetti, Adele
    Funaro, Alfonso
    Negrini, Paola
    JOURNAL OF INVASIVE CARDIOLOGY, 2015, 27 (09): : 430 - 434
  • [6] Percutaneous closure of patent foramen ovale using the HELEX septal occluder
    Reschke, M
    Ostermayer, S
    Büscheck, F
    Bayard, Y
    Billinger, K
    Trepels, T
    Sievert, H
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 13L - 13L
  • [7] Using the GORE® Septal Occluder (GSO) in Challenging Patent Foramen Ovale (PFO) Anatomies
    Geis, Nicolas A.
    Pleger, Sven T.
    Katus, Hugo A.
    Hardt, Stefan E.
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2015, 28 (02) : 190 - 197
  • [8] Percutaneous transcatheter closure of patent foramen ovale with the Amplatzer Cribriform septal occluder
    Silvestry, Frank E.
    Naseer, Nauman
    Wiegers, Susan E.
    Hirshfeld, John W., Jr.
    Herrmann, Howard C.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 71 (03) : 383 - 387
  • [9] Closure of patent foramen ovale with CardioSEAL septal occluder: A safe intervention.
    Sommer, RJ
    Kramer, PH
    Sorensen, SG
    Forbes, T
    O'Donnell, M
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (6A): : 136H - 136H
  • [10] Transcatheter closure of atrial septal defects and patent foramen ovale using the Helex septal occluder
    Ostermayer, SHU
    Wilson, N
    Billinger, K
    Reschke, M
    Bayard, Y
    Buescheck, F
    Fischer, E
    Leetz, M
    Taaffe, M
    Hein, R
    Roemer, A
    Sievert, H
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 91H - 91H