Relationship between intra-abdominal pressure and indocyanine green plasma disappearance rate: hepatic perfusion may be impaired in critically ill patients with intra-abdominal hypertension

被引:28
|
作者
Malbrain, Manu L. N. G. [1 ]
Viaene, Dries [1 ]
Kortgen, Andreas [2 ]
De Laet, Inneke [1 ]
Dits, Hilde [1 ]
Van Regenmortel, Niels [1 ]
Schoonheydt, Karen [1 ]
Bauer, Michael [2 ]
机构
[1] Netwerk Antwerpen ZNA Stuivenberg, Dept Intens Care, Antwerp, Belgium
[2] Jena Univ Hosp, Dept Anaesthesiol & Intens Care Therapy, Ctr Sepsis Control & Care, D-07747 Jena, Germany
来源
关键词
Receiver Operating Characteristic; Sequential Organ Failure Assessment Score; Hepatic Blood Flow; Abdominal Compartment Syndrome; Receiver Operating Characteristic Curve Analysis;
D O I
10.1186/2110-5820-2-S1-S19
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Monitoring hepatic blood flow and function might be crucial in treating critically ill patients. Intra-abdominal hypertension is associated with decreased abdominal blood flow, organ dysfunction, and increased mortality. The plasma disappearance rate (PDR) of indocyanine green (ICG) is considered to be a compound marker for hepatosplanchnic perfusion and hepatocellular membrane transport and correlates well with survival in critically ill patients. However, correlation between PDRICG and intra-abdominal pressure (IAP) remains poorly understood. The aim of this retrospective study was to investigate the correlation between PDRICG and classic liver laboratory parameters, IAP and abdominal perfusion pressure (APP). The secondary goal was to evaluate IAP, APP, and PDRICG as prognostic factors for mortality. Methods: A total of 182 paired IAP and PDRICG measurements were performed in 40 critically ill patients. The mean values per patient were used for comparison. The IAP was measured using either a balloon-tipped stomach catheter connected to an IAP monitor (Spiegelberg, Hamburg, Germany, or CiMON, Pulsion Medical Systems, Munich, Germany) or a bladder FoleyManometer (Holtech Medical, Charlottenlund, Denmark). PDRICG was measured at the bedside using the LiMON device (Pulsion Medical Systems, Munich, Germany). Primary endpoint was hospital mortality. Results: There was no significant correlation between PDRICG and classic liver laboratory parameters, but PDRICG did correlate significantly with APP (R = 0.62) and was inversely correlated with IAP (R = -0.52). Changes in PDRICG were associated with significant concomitant changes in APP (R = 0.73) and opposite changes in IAP (R = 0.61). The IAP was significantly higher (14.6 +/- 4.6 vs. 11.1 +/- 5.3 mmHg, p = 0.03), and PDRICG (10 +/- 8.3 vs. 15.9 +/- 5.2%, p = 0.02) and APP (43.6 +/- 9 vs. 57.9 +/- 12.2 mmHg, p < 0.0001) were significantly lower in non-survivors. Conclusions: PDRICG is positively correlated to APP and inversely correlated to IAP. Changes in APP are associated with significant concomitant changes in PDRICG, while changes in IAP are associated with opposite changes in PDRICG, suggesting that an increase in IAP may compromise hepatosplanchnic perfusion. Both PDRICG and IAP are correlated with outcome. Measurement of PDRICG may be a useful additional clinical tool to assess the negative effects of increased IAP on liver perfusion and function.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Relationship between intra-abdominal pressure and indocyanine green plasma disappearance rate: hepatic perfusion may be impaired in critically ill patients with intra-abdominal hypertension
    Manu LNG Malbrain
    Dries Viaene
    Andreas Kortgen
    Inneke De laet
    Hilde Dits
    Niels Van Regenmortel
    Karen Schoonheydt
    Michael Bauer
    [J]. Annals of Intensive Care, 2
  • [2] Intra-abdominal pressure and intra-abdominal hypertension in critically ill obstetric patients: a prospective cohort study
    Tyagi, A.
    Singh, S.
    Kumar, M.
    Sethi, A. K.
    [J]. INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2017, 32 : 33 - 40
  • [3] Liver function assessment by indocyanine green plasma disappearance rate in patients with intra-abdominal hypertension after "non-hepatic" abdominal surgery
    Kovac, Natasa
    Peric, Mladen
    [J]. CURRENT MEDICAL RESEARCH AND OPINION, 2018, 34 (10) : 1741 - 1746
  • [4] Intra-abdominal pressure in critically ill pediatric patients
    Scarani, R.
    Calderini, E.
    Leoncino, S.
    Pelosi, P.
    [J]. ACTA CLINICA BELGICA, 2007, 62 : 271 - 271
  • [5] Can Intra-abdominal Pressure Predict the Pharmacokinetics of Aminoglycosides in Critically Ill Patients With Intra-abdominal Sepsis?
    Shahrami, Bita
    Arabzadeh, Amir Ahmad
    Najmeddin, Farhad
    Sefidani Forough, Aida
    Najafi, Atabak
    Rouini, Mohammad Reza
    Mojtahedzadeh, Mojtaba
    [J]. AMERICAN JOURNAL OF THERAPEUTICS, 2022, 29 (03) : E376 - E378
  • [6] Abdominal perfusion pressure monitoring in intra-abdominal hypertension
    Cheatham, Michael L.
    [J]. ACTA CLINICA BELGICA, 2009, 64 (03) : 244 - 244
  • [7] Intra-abdominal pressure, intra-abdominal hypertension, and pregnancy: a review
    Rosaleen Chun
    Andrew W Kirkpatrick
    [J]. Annals of Intensive Care, 2
  • [8] Intra-abdominal pressure, intra-abdominal hypertension, and pregnancy: a review
    Chun, Rosaleen
    Kirkpatrick, Andrew W.
    [J]. ANNALS OF INTENSIVE CARE, 2012, 2
  • [9] Intra-abdominal pressure in critically ill patients: it is worthwhile to measure?
    Chiumello, D.
    [J]. MINERVA ANESTESIOLOGICA, 2007, 73 (09) : 445 - 446
  • [10] Abdominal perfusion pressure is superior from intra-abdominal pressure to detect deterioration of renal perfusion in critically Ill patients
    Gul, Fethi
    Sayan, Ismet
    Kasapoglu, Umut Sabri
    Erol, Derya Ozer
    Arslantas, Mustafa Kemal
    Cinel, Ismail
    Aykac, Zuhal
    [J]. ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2019, 25 (06): : 561 - 566