Simultaneous detection of guanine and adenine in DNA and meat samples using graphitized mesoporous carbon modified electrode

被引:60
|
作者
Thangaraj, Rajendiran [1 ]
Kumar, Annamalai Senthil [1 ]
机构
[1] Vellore Inst Technol Univ, Environm & Analyt Chem Div, Sch Adv Sci, Vellore 632014, Tamil Nadu, India
关键词
Graphitized mesoporous carbon; Simultaneous detection; Guanine; Adenine; DNA; ELECTROCHEMICAL DETERMINATION; CAPILLARY-ELECTROPHORESIS; NANOTUBES; PURINE; FILM; NANOPARTICLES; OXIDATION; GRAPHENE; BEHAVIOR; TYROSINE;
D O I
10.1007/s10008-012-1895-0
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A graphitized mesoporous carbon modified glassy carbon electrode (GCE/GMC) prepared by drop coating method without any pre-anodization of the underlying GCE or external binder/matrix, has been demonstrated for simultaneous electrochemical oxidation of guanine (G) and adenine (A) at oxidation potentials 0.60 and 0.85 V vs. Ag/AgCl, respectively, in the presence of thymine (T) by differential pulse voltammetric method in pH 7 phosphate buffer solution. Control voltammetric experiments with unmodified GCE, graphite nanopowder and multiwalled carbon nanotube modified electrodes yielded either feeble or with high-background current responses. Interestingly, the GCE/GMC showed highly efficient, stable and well-defined voltammetric signals. Thymine oxidation signal noticed discretely at 1.15 V vs. Ag/AgCl on the GCE/GMC was not influenced for the simultaneous determination of G and A. Constructed DPV calibration graphs were linear in the range of 25-200 and 25-150 mu M, respectively, for the G and A. Corresponding detection limit (S/N = 3) values are 0.76 and 0.63 mu M. Real sample analyses for the detection of G and A concentrations in calf-thymus DNA (detected [G]/[A] ratio = 0.82), beef brain and beef liver were successfully demonstrated with recovery values 100 %.
引用
收藏
页码:583 / 590
页数:8
相关论文
共 50 条
  • [1] Simultaneous detection of guanine and adenine in DNA and meat samples using graphitized mesoporous carbon modified electrode
    Rajendiran Thangaraj
    Annamalai Senthil Kumar
    Journal of Solid State Electrochemistry, 2013, 17 : 583 - 590
  • [2] Simultaneous differential pulse voltammetric analysis of guanine and adenine using graphitized carbon nanofibers modified electrode
    Thangaraj, Rajendiran
    Kumar, Annamalai Senthil
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2015, 92 (04) : 493 - 496
  • [3] Simultaneous determination of guanine and adenine in DNA using an electrochemically pretreated glassy carbon electrode
    Wang, HS
    Ju, HX
    Chen, HY
    ANALYTICA CHIMICA ACTA, 2002, 461 (02) : 243 - 250
  • [4] Simultaneous determination of guanine and adenine contents in DNA, RNA and synthetic oligonucleotides using a chemically modified electrode
    Zen, JM
    Chang, MR
    Ilangovan, G
    ANALYST, 1999, 124 (05) : 679 - 684
  • [5] Fabrication of polythionine/NPAu/MWNTs modified electrode for simultaneous determination of adenine and guanine in DNA
    Liu, Hongying
    Wang, Guangfeng
    Chen, Daolei
    Zhang, Wei
    Li, Ing
    Fang, Bin
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 128 (02) : 414 - 421
  • [6] Simultaneous voltammetry detection of guanine and adenine in human serum with a CQDs / AuNPs @ MWCNTs modified glassy carbon electrode
    Jiang, Jiang
    Zhuang, Qizhao
    Deng, Shiting
    Kong, Dexian
    Chi, Yuwu
    Chinese Journal of Analysis Laboratory, 2021, 40 (12) : 1419 - 1424
  • [7] A glassy carbon electrode modified with electrochemically reduced graphene for simultaneous determination of guanine and adenine
    Zhu, Xiaohua
    Zeng, Lixuan
    Xu, Maotian
    Liang, Yong
    Nan, Junmin
    ANALYTICAL METHODS, 2012, 4 (09) : 2935 - 2939
  • [8] Simultaneous detection of guanine, adenine, thymine, and cytosine at polyaniline/MnO2 modified electrode
    Prathap, M. U. Anu
    Srivastava, Rajendra
    Satpati, Biswarup
    ELECTROCHIMICA ACTA, 2013, 114 : 285 - 295
  • [9] Electrodeposit nano-copper oxide on glassy carbon electrode for simultaneous detection of guanine and adenine
    Zhang, Xiaoyan
    Liang, Xian
    Xu, Mai
    Bao, Xia
    Wang, Fengwu
    Yang, Zhousheng
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2012, 42 (06) : 375 - 381
  • [10] Electrodeposit nano-copper oxide on glassy carbon electrode for simultaneous detection of guanine and adenine
    Xiaoyan Zhang
    Xian Liang
    Mai Xu
    Xia Bao
    Fengwu Wang
    Zhousheng Yang
    Journal of Applied Electrochemistry, 2012, 42 : 375 - 381