Modeling and Experimental Analysis of Overvoltage and Inrush Current Characteristics of the Electric Rail Traction Power Supply System

被引:4
|
作者
Sun, Jixing [1 ]
Hu, Kaixuan [1 ]
Fan, Yongzhi [1 ]
Liu, Jiyong [1 ,2 ]
Yan, Shengchun [2 ]
Zhang, Yan [2 ]
机构
[1] Beijing Jiaotong Univ, Sch Elect Engn, 3 Shangyuancun Haidian Dist, Beijing 100044, Peoples R China
[2] Shuohuang Railway Dev Co Ltd Natl Energy, Cangzhou 062350, Peoples R China
基金
中国国家自然科学基金;
关键词
inrush current; high-speed train; over voltage; traction power supply system; vehicle; VACUUM CIRCUIT-BREAKER; SWITCHING OVERVOLTAGES; TRANSIENTS; INTERRUPTERS; SIMULATION; FREQUENCY; SURGE; FIELD;
D O I
10.3390/en15249308
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
High-speed EMUs (electric multiple-units) frequently pass through the phase-separation zone during operation. Overvoltage generated during the operation of the vehicle-mounted circuit breaker has a long duration and high waveform steepness, which accelerates the service life of the vehicle-mounted equipment and is likely to cause insulation failures. For the above-mentioned problems, the operating overvoltage characteristics of high-speed EMU were obtained by traction substation-catenary-EMUs system (SCES) analysis and experiments, thus deriving the influences of the closed phase angle and the residual magnetism of the vehicle-mounted transformer on operating overvoltage. The results showed that the voltage phase of the catenary significantly affected the operating overvoltage, and the closed switching overvoltage was small at 0-40 degrees, 140-210 degrees and 320-350 degrees. The voltage on the primary side of the vehicle-mounted transformer was 60.78 kV, with the transient impact of high-frequency oscillation overvoltage of 22.71 kV, and an initial period of oscillation of 0.01 ms. Then, the period became longer, and it took 0.5 ms for the high-frequency oscillation from attenuation to disappearance. Finally, a scheme of series reactance suppression devices was proposed to protect vehicle-mounted voltage transformers. This work is to provide data support for the insulation design and system protection of a traction power supply system.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Modeling and Analysis of Traction Power Supply System of Urban Rail Transit
    Wang, Yikai
    He, Xiaoqiong
    [J]. 2022 IEEE 17TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2022, : 744 - 749
  • [2] Modeling and Analysis of Contactless Traction Power Supply System for Urban Rail Transit
    Liu Shuguang
    Ye Zhenxing
    [J]. PROCEEDINGS OF THE 32ND 2020 CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2020), 2020, : 5653 - 5657
  • [3] Analysis of Rail Potential Characteristics of AC/DC Dual-system Traction Power Supply System
    Chen, Minwu
    Fu, Haochun
    Xie, Chonghao
    Liu, Weidong
    Xu, Wei
    [J]. Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2022, 57 (04): : 729 - 736
  • [4] Analysis of Rail Potential and Stray Current with an Unified Chain Model of Dual Traction Power Supply System
    Bhatti, Ashfaque Ahmed
    Liu, Wei
    Yang, Lingyun
    Ma, Qingan
    Pan, Zhe
    Li, Songyuan
    Xu, Qian
    Li, Mingze
    [J]. URBAN RAIL TRANSIT, 2024, 10 (03) : 248 - 262
  • [5] Light rail transit DC traction power system surge overvoltage protection
    Paul, D
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2002, 38 (01) : 21 - 28
  • [6] Light rail transit DC traction power system surge overvoltage protection
    Paul, D
    [J]. 2001 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE, CONFERENCE RECORD, 2001, : 83 - 90
  • [7] Reliability Analysis of DC Traction Power Supply System for Electric Railway
    Hayashiya, Hitoshi
    Masuda, Masayoshi
    Noda, Yukihisa
    Suzuki, Koichiro
    Suzuki, Takashi
    [J]. 2017 19TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'17 ECCE EUROPE), 2017,
  • [8] Analysis of the lightning overvoltage in the power cables of the dc electric traction system for the electrified railway in Hongkong
    Shanghai Lightning Protection Center, Shanghai 201615, China
    不详
    不详
    [J]. Zhongguo Tiedao Kexue, 2009, 4 (91-95):
  • [9] Study on Modeling and Simulation of Rail Transit Traction Power Supply System in Urban Power Distribution System by using PSCAD
    Rong, Na
    Han, Song
    Li, Tian-lin
    Peng, Xiao-jun
    [J]. 2014 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2014,
  • [10] Electrical characteristics of new three-phase traction power supply system for rail transit
    Xiaohong Huang
    Hanlin Wang
    Qunzhan Li
    Naiqi Yang
    Tao Ren
    You Peng
    Haoyang Li
    [J]. Railway Engineering Science, 2023, (01) : 75 - 88