Analysis of Electromagnetic Environment Optimization Measures for UHV Transmission Lines

被引:0
|
作者
Shang, Liqun [1 ]
Zhu, Weiwei [1 ]
机构
[1] Xian Univ Sci & Technol, Coll Elect & Control Engn, Xian 710054, Shaanxi, Peoples R China
关键词
Electric field intensity; transmission lines; shielded wires; shielding effect;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
To reduce the electric field intensity under UHV transmission lines based on erecting shielded wires, this paper studies shielding effect of shield wire from four aspects, respectively, the number, erection height, radius and arrangement, so as to seek the optimal position of the shield wire. In addition, simulation results verify that reasonable setting of shielded wire parameters can control the electric field below the transmission line within the limiting value.
引用
收藏
页码:8975 / 8978
页数:4
相关论文
共 50 条
  • [1] Analysis of Switching Overvoltage and Suppression Measures in UHV Transmission Lines
    Han Yanan
    Han Bin
    Xiang Zutao
    CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2019, 42 (04): : 209 - 214
  • [2] Study on electromagnetic environment of ±800 kV UHV DC and 1000 kV UHV AC parallel transmission lines
    Wang, Guangzhou
    Yao, Degui
    Zhang, Songyang
    Wang, Donghui
    Wang, Leilei
    Guo, Xing
    Yang, Fan
    FOURTH INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2020, 467
  • [3] Measurement and Analysis on Electromagnetic Environment of 1000kV UHV AC Transmission Line
    Zhao, Luxing
    Lu, Jiayu
    Wu, Guifang
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [4] Electromagnetic environment analysis of a software park near transmission lines
    He, JL
    Chen, SM
    Guo, E
    Zeng, R
    Lee, J
    Chang, SH
    Zhang, B
    Zou, J
    Guan, ZC
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (04) : 995 - 1002
  • [5] Electromagnetic environment analysis of a software park near transmission lines
    He, JL
    Chen, SM
    Guo, J
    Zeng, R
    Zou, J
    Guan, ZC
    2003 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE, CONFERENCE RECORD, 2003, : 77 - 84
  • [6] ELECTROMAGNETIC IMPACT OF TRANSMISSION LINES ON THE ENVIRONMENT
    Ristovski, Leko
    Delipetrov, Todor
    Blazev, Krsto
    Serafimovski, Toni
    GEOCONFERENCE ON SCIENCE AND TECHNOLOGIES IN GEOLOGY, EXPLORATION AND MINING, SGEM 2013, VOL II, 2013, : 749 - 755
  • [7] Research on Electro-Magnetic Environment of UHV Transmission Lines
    By Wu Guifang
    Electricity, 2005, (03) : 42 - 46
  • [8] Electromagnetic environment of the overhead transmission lines and electromagnetic pollution
    Wu, Xiong
    Nie, Dingzhen
    Wan, Baoquan
    Zhang, Guangzhou
    Gaodianya Jishu/High Voltage Engineering, 2000, 26 (05): : 24 - 26
  • [9] Effects of Electromagnetic Field of UHV Transmission Lines Exposure on Testis Tissue in Mice
    Geng, Duyan
    Xu, Guizhi
    Zhang, Xianghong
    Xing, Lingxiao
    Guo, Hongyong
    Yan, Weili
    Wang, Youhua
    IEEE TRANSACTIONS ON MAGNETICS, 2009, 45 (10) : 4853 - 4856
  • [10] Analysis of the Influence of the Number of Split Wires on the UHV Electromagnetic Environment
    Wang, Ni
    2022 IEEE INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, BIG DATA AND ALGORITHMS (EEBDA), 2022, : 1017 - 1019