Optimum values of process parameters of the "Wet Limestone Flue Gas Desulfurization System"

被引:0
|
作者
Warych, J [1 ]
Szymanowski, M [1 ]
机构
[1] Warsaw Univ Technol, Dept Chem & Proc Engn, PL-00645 Warsaw, Poland
关键词
D O I
10.1002/1521-4125(200204)25:4<427::AID-CEAT427>3.0.CO;2-X
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this article the method of cost optimization of the "Wet Limestone Flue Gas Desulfurization System" is presented. The optimization calculations include process and cost models. The process model describes the most important stage Of SO2 removal that runs in the absorber and in the holding tank. It includes absorption of sulfur dioxide, oxidation of SO32-, dissolution of limestone, and crystallization of gypsum. The model was applied to calculate indispensable parameters for estimating costs and then to minimize capital and operating costs. Costs of all important equipment were estimated, such as SO2 removal systems with the absorber and the holding tank, reagent feed system with the ball mill and dewatering gypsum slurry system. Optimum values of the process parameters for different conditions of running flue gas desulfurization system were found. The process and cost model can be useful when designing the wet limestone FGD systems and carrying out economic analysis of the flue Gas desulfurization plants.
引用
收藏
页码:427 / 432
页数:6
相关论文
共 50 条
  • [1] Optimum values of process parameters of the wet limestone flue gas desulfurization system
    Warych, J.
    Szymanowski, M.
    Chemical Engineering and Technology, 2002, 25 (04): : 427 - 432
  • [2] Reactivity of limestone in wet flue gas desulfurization system
    Guo, Rui-Tang
    Gao, Xiang
    Wang, Jun
    Luo, Zhong-Yang
    Ni, Ming-Jiang
    Cen, Ke-Fa
    Ranshao Kexue Yu Jishu/Journal of Combustion Science and Technology, 2007, 13 (06): : 485 - 490
  • [4] Reactivity of the limestone in wet flue gas desulfurization
    2005, Science Press, Beijing, China (26):
  • [5] Model of the wet limestone flue gas desulfurization process for cost optimization
    Warych, J
    Szymanowski, M
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2001, 40 (12) : 2597 - 2605
  • [6] Optimization of Limestone-gypsum Wet Flue Gas Desulfurization System
    Han, Jing
    Zhu, Guoyue
    PROCEEDINGS OF THE 2016 4TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY AND ENVIRONMENTAL TECHNOLOGY (ICREET 2016), 2017, 112 : 71 - 73
  • [7] Influence of liquid to gas ratio on the desulfurization process in limestone-gypsum wet flue gas desulfurization
    School of Energy and Power, Shandong University, Jinan 250061, China
    不详
    Dongli Gongcheng, 2007, 3 (422-426):
  • [8] Evaluation of limestone reactivity in wet flue gas desulfurization
    National Key Lab of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China
    Dongli Gongcheng, 2008, 3 (430-432):
  • [9] Characterization of the reactivity of limestone for wet flue gas desulfurization
    Fellner, P
    Khandl, V
    CHEMICKE LISTY, 1997, 91 (09): : 787 - 788
  • [10] Modeling of Wet Flue Gas Desulfurization Process for Utilization of Low-Grade Limestone
    Lim, Jonghun
    Choi, Yeongryeol
    Kim, Geonyeol
    Song, Hojun
    Kim, Junghwan
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2019, 57 (05): : 743 - 748