A flexible protruding microelectrode array for neural interfacing in bioelectronic medicine

被引:22
|
作者
Steins, Helen [1 ,2 ]
Mierzejewski, Michael [1 ]
Brauns, Lisa [1 ]
Stumpf, Angelika [1 ]
Kohler, Alina [1 ]
Heusel, Gerhard [1 ]
Corna, Andrea [1 ,3 ]
Herrmann, Thoralf [1 ]
Jones, Peter D. [1 ]
Zeck, Guenther [1 ,3 ]
von Metzen, Rene [1 ]
Stieglitz, Thomas [2 ,4 ,5 ]
机构
[1] Univ Tubingen, NMI Nat & Med Sci Inst, Reutlingen, Germany
[2] Univ Freiburg, Dept Microsyst Engn, Lab Biomed Microtechnol, Freiburg, Germany
[3] TU Wien, Inst Biomed Elect, Vienna, Austria
[4] Univ Freiburg, Bernstein Ctr Freiburg, Freiburg, Germany
[5] Univ Freiburg, BrainLinks BrainTools, Freiburg, Germany
来源
MICROSYSTEMS & NANOENGINEERING | 2022年 / 8卷 / 01期
关键词
VAGUS-NERVE-STIMULATION; ELECTRICAL-PROPERTIES; IN-VITRO; POLYIMIDE; SYSTEM; AXONS; RESTORATION; ELECTRODES; VISCERA; MOTOR;
D O I
10.1038/s41378-022-00466-z
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Recording neural signals from delicate autonomic nerves is a challenging task that requires the development of a lowinvasive neural interface with highly selective, micrometer-sized electrodes. This paper reports on the development of a three-dimensional (3D) protruding thin-film microelectrode array (MEA), which is intended to be used for recording low-amplitude neural signals from pelvic nervous structures by penetrating the nerves transversely to reduce the distance to the axons. Cylindrical gold pillars (empty set 20 or 50 mu m, similar to 60 mu m height) were fabricated on a micromachined polyimide substrate in an electroplating process. Their sidewalls were insulated with parylene C, and their tips were optionally modified by wet etching and/or the application of a titanium nitride (TiN) coating. The microelectrodes modified by these combined techniques exhibited low impedances (similar to 7 k Omega at 1 kHz for empty set 50 mu m microelectrode with the exposed surface area of similar to 5000 mu m(2)) and low intrinsic noise levels. Their functionalities were evaluated in an ex vivo pilot study with mouse retinae, in which spontaneous neuronal spikes were recorded with amplitudes of up to 66 mu V. This novel process strategy for fabricating flexible, 3D neural interfaces with low-impedance microelectrodes has the potential to selectively record neural signals from not only delicate structures such as retinal cells but also autonomic nerves with improved signal quality to study neural circuits and develop stimulation strategies in bioelectronic medicine, e.g., for the control of vital digestive functions.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] A flexible protruding microelectrode array for neural interfacing in bioelectronic medicine
    Helen Steins
    Michael Mierzejewski
    Lisa Brauns
    Angelika Stumpf
    Alina Kohler
    Gerhard Heusel
    Andrea Corna
    Thoralf Herrmann
    Peter D. Jones
    Günther Zeck
    Rene von Metzen
    Thomas Stieglitz
    Microsystems & Nanoengineering, 8
  • [2] Flexible microelectrode array for interfacing with the surface of neural ganglia
    Sperry, Zachariah J.
    Na, Kyounghwan
    Parizi, Saman S.
    Chiel, Hillel J.
    Seymour, John
    Yoon, Euisik
    Bruns, Tim M.
    JOURNAL OF NEURAL ENGINEERING, 2018, 15 (03)
  • [3] A polynorbornene-based microelectrode array for neural interfacing
    Hess, Allison E.
    Dunning, Jeremy L.
    Tyler, Dustin J.
    Zorman, Christian A.
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [4] Fabrication of Pyramid-Shaped Three-Dimensional Flexible Microelectrode Array for Improved Neural Interfacing
    Zhou, Hong-Bo
    Li, Gang
    Sun, Xiao-Na
    Zhu, Zhuang-Hui
    Lou, Xin-Hui
    Zhang, Hua
    Liang, Ting
    Jin, Qing-Hui
    Zhao, Jian-Long
    Ren, Qiu-Shi
    SENSOR LETTERS, 2009, 7 (01) : 96 - 103
  • [5] A FLEXIBLE PERFORATED MICROELECTRODE ARRAY FOR EXTENDED NEURAL RECORDINGS
    BOPPART, SA
    WHEELER, BC
    WALLACE, CS
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (01) : 37 - 42
  • [6] Distributed implantation of a flexible microelectrode array for neural recording
    Chunrong Wei
    Yang Wang
    Weihua Pei
    Xinyong Han
    Longnian Lin
    Zhiduo Liu
    Gege Ming
    Ruru Chen
    Pingping Wu
    Xiaowei Yang
    Li Zheng
    Yijun Wang
    Microsystems & Nanoengineering, 8
  • [7] Distributed implantation of a flexible microelectrode array for neural recording
    Wei, Chunrong
    Wang, Yang
    Pei, Weihua
    Han, Xinyong
    Lin, Longnian
    Liu, Zhiduo
    Ming, Gege
    Chen, Ruru
    Wu, Pingping
    Yang, Xiaowei
    Zheng, Li
    Wang, Yijun
    MICROSYSTEMS & NANOENGINEERING, 2022, 8 (01)
  • [8] Flexible neural electrode array based- in vivo bioelectronic nose
    Duan, Yan
    Wang, Suhao
    Yuan, Qunchen
    Shi, Yingqian
    Zhuang, Liujing
    Song, Jizhou
    Wang, Ping
    2022 IEEE INTERNATIONAL SYMPOSIUM ON OLFACTION AND ELECTRONIC NOSE (ISOEN 2022), 2022,
  • [9] Flexible microelectrode for interfacing regenerating peripheral nerves
    Suzuki, T
    Maeda, T
    Chinzei, T
    Mabuchi, K
    Imachi, K
    Tachi, S
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2270 - 2272
  • [10] Fabrication of a flexible three-dimensional neural microelectrode array
    Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
    不详
    不详
    Guangxue Jingmi Gongcheng, 2008, 8 (1396-1402):