Automated breast ultrasound:: Lesion detection and BI-RADS™ classification -: a pilot study

被引:67
|
作者
Wenkel, E. [1 ]
Heckmann, M. [1 ]
Heinrich, M. [1 ]
Schwab, S. A. [1 ]
Uder, M. [1 ]
Schulz-Wendtland, R. [1 ]
Bautz, W. A. [1 ]
Janka, R. [1 ]
机构
[1] Univ Klinikum Erlangen, Inst Radiol, D-91052 Erlangen, Germany
关键词
breast; ultrasound; automated; ABUS; lesion detection; breast cancer;
D O I
10.1055/s-2008-1027563
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Evaluation of an automated breast ultrasound system (ABUS) regarding the detection and classification of breast lesions according to BI-RADS. Materials and Methods: Women were selected for the study who had unclear findings in breast diagnosis performed elsewhere (palpation, sonography or mammography) and who were referred for further work-Up. All patients received a hand-held ultrasonography (HHUS) with a 13 MHz transducer, clinical examination and mammography of both breasts. Additionally, the affected breast received the ABUS (SomoVuTM, U-Systems, Inc., San Jose, CA, USA: EC Representative: Siemens, Erlangen, Germany) which was performed with an 8 MHz transducer. Five radiologists independently evaluated the ABUS images regarding lesion detectability. All detected lesions were classified according to BI-RADS assessment. The examiners had no knowledge of the patients' clinical examination or of the result of the mammography or the HHUS. Results of the ABUS were compared to HHUS. Results: 35 women were included in the study. 25 BI-RADS 4 or 5 lesions had further histological (n = 23) or cytological (n = 2) work-up which revealed 13 malignant and 12 benign findings. The size of all lesions ranged from 6 to 32 mm (median 14 mm). With the ABUS all examiners detected 29 to 30 lesions while HHUS revealed 30 lesions. One Suspicious area in HHUS was not reported by any of the five examiners with the ABUS. Histology of this area revealed mastopathic disease. No benign lesion was classified as BI-RADS 5 with the ABUS or HHUS. All breast cancers were found with the ABUS by all examiners and correctly classified as BI-RADS 4 or 5. There was good agreement regarding BI-RADS classification of HHUS and ABUS for the five different examiners with Kappa values between 0.83 and 0.87. Conclusion: These preliminary results show that the ABUS allows detection of solid and cystic lesions and their BI-RADS classification with a high reliability in a selected patient group.
引用
收藏
页码:804 / 808
页数:5
相关论文
共 50 条
  • [1] Detection and diagnosis of automated breast ultrasound in patients with BI-RADS category 4 microcalcifications: a retrospective study
    Yu, Li-Fang
    Dai, Chao-Chao
    Zhu, Luo-Xi
    Xu, Xiao-Jing
    Yan, Hong-Ju
    Jiang, Chen-Xiang
    Bao, Ling-Yun
    [J]. BMC MEDICAL IMAGING, 2024, 24 (01):
  • [2] Interobserver concordance in the BI-RADS classification of breast ultrasound exams
    Calas, Maria Julia G.
    Almeida, Renan M. V. R.
    Gutfilen, Bianca
    Pereira, Wagner C. A.
    [J]. CLINICS, 2012, 67 (02) : 185 - 189
  • [3] Automated Breast Ultrasound vs. Handheld Ultrasound: BI-RADS Classification, Duration of the Examination and Patient Comfort
    Prosch, H.
    Halbwachs, C.
    Strobl, C.
    Reisner, L. -M.
    Hondl, M.
    Weber, M.
    Mostbeck, G. H.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2011, 32 (05): : 504 - 510
  • [4] Prognostic importance of ultrasound BI-RADS classification in breast cancer patients
    Kim, Ju-Yeon
    Jung, Eun Jung
    Park, Taejin
    Jeong, Sang-Ho
    Jeong, Chi-Young
    Ju, Young-Tae
    Lee, Young-Joon
    Hong, Soon-Chan
    Ha, Woo-Song
    Choi, Sang-Kyung
    [J]. JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2015, 45 (05) : 411 - 415
  • [5] Breast Ultrasound Image BI-RADS Classification Based on Vision Transformer
    Wei, Yanbo
    Ye, Junbo
    Li, Xiaofeng
    Zhao, Yuanyuan
    Wang, Yanwei
    [J]. INTERNATIONAL JOURNAL OF MULTIPHYSICS, 2024, 18 (02) : 32 - 39
  • [6] Agreement in breast lesion assessment and final BI-RADS classification between radial and meander-like breast ultrasound
    Pascale Brasier-Lutz
    Claudia Jäggi-Wickes
    Sabine Schaedelin
    Rosemarie Burian
    Cora-Ann Schoenenberger
    Rosanna Zanetti-Dällenbach
    [J]. BMC Medical Imaging, 21
  • [7] Agreement in breast lesion assessment and final BI-RADS classification between radial and meander-like breast ultrasound
    Brasier-Lutz, Pascale
    Jaggi-Wickes, Claudia
    Schaedelin, Sabine
    Burian, Rosemarie
    Schoenenberger, Cora-Ann
    Zanetti-Dallenbach, Rosanna
    [J]. BMC MEDICAL IMAGING, 2021, 21 (01)
  • [8] Diagnostic value of breast ultrasound BI-RADS classification combined with TGF-β detection in breast cancer patients
    Gao, Yakun
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (08): : 12186 - 12192
  • [9] Accuracy of classification of breast ultrasound findings based on criteria used for BI-RADS
    Heinig, J.
    Witteler, R.
    Schmitz, R.
    Kiesel, L.
    Steinhard, J.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 32 (04) : 573 - 578
  • [10] Quantitative Ultrasound Analysis for Classification of BI-RADS Category 3 Breast Masses
    Woo Kyung Moon
    Chung-Ming Lo
    Jung Min Chang
    Chiun-Sheng Huang
    Jeon-Hor Chen
    Ruey-Feng Chang
    [J]. Journal of Digital Imaging, 2013, 26 : 1091 - 1098