Comparison of the BD Viper System With XTR Technology to the Gen-Probe APTIMA COMBO 2 Assay Using the TIGRIS DTS System for the Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Urine Specimens

被引:9
|
作者
Mushanski, Linda M. [1 ]
Brandt, Ken [1 ]
Coffin, Nicolette [1 ]
Levett, Paul N. [1 ]
Horsman, Gregory B. [1 ]
Rank, Elliot L. [2 ]
机构
[1] Saskatchewan Dis Control Lab, Regina, SK S4S 0A4, Canada
[2] BD Diagnost, Sparks, MD USA
关键词
ACID AMPLIFICATION TESTS;
D O I
10.1097/OLQ.0b013e31824f2f5b
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Performances of the BD ProbeTec Chlamydia trachomatis (CT)/Neisseria Gonorrhoeae (GC) Q(x) Amplified DNA Assay reagents on a BD Viper System with XTR Technology and APTIMA COMBO 2 Assay reagents on a TIGRIS DTS platform, for detection of both CT and GC were compared. Methods: A total of 1018 first-void urine specimens were tested for the presence of CT and GC DNA using the 2 assays. Results: CT was detected in 143 specimens (14%). Eight specimens exhibited discordant results, and they were divided equally between the 2 assays. Based on the original results, the overall agreement for CT was 99.2%, with 97.1% and 99.5% in agreement with positive and negative specimens, respectively. Cohen's Kappa was 0.967. GC was detected in 27 specimens (2.6%). Two specimens exhibited discordant results, and they were divided equally between the 2 assays. Based on the original results, the overall agreement was 99.8%, with 96.2% and 99.9% in agreement for positive and negative specimens, respectively. Cohen's Kappa was 0.961. Conclusions: There was a high level of agreement between the systems for both CT and GC detection.
引用
下载
收藏
页码:514 / 517
页数:4
相关论文
共 49 条
  • [1] Detection of Neisseria gonorrhoeae and Chlamydia trachomatis in pharyngeal and rectal specimens using the BD Probetec ET system, the Gen-Probe Aptima Combo 2 assay and culture
    Ota, K. V.
    Tamari, I. E.
    Smieja, M.
    Jamieson, F.
    Jones, K. E.
    Towns, L.
    Juzkiw, J.
    Richardson, S. E.
    SEXUALLY TRANSMITTED INFECTIONS, 2009, 85 (03) : 182 - 186
  • [2] Comparison of the gen-probe APTIMA Combo 2 assay to the AMPLICOR CT/NG assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in urine samples from Australian men and women
    Lowe, Peter
    O'Loughlin, Peter
    Evans, Kathryn
    White, Michael
    Bartley, Paul B.
    Vohra, Renu
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (07) : 2619 - 2621
  • [3] Multicenter clinical trial performance of the new Gen-Probe APTIMA Combo 2 assay for detecting Chlamydia trachomatis and Neisseria gonorrhoeae in female and male urine specimens.
    Ferrero, DV
    Gaydos, CA
    Quinn, TC
    Hook, EW
    Martin, DH
    Schachter, J
    Weissfeld, A
    Willis, D
    CLINICAL CHEMISTRY, 2001, 47 (06) : A97 - A97
  • [4] Analytical Reproducibility of the BD Viper™ System with XTR Technology (extracted mode) for the Detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Welborn, C.
    LeBar, W.
    Taylor, S.
    Hook, E. W.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A170 - A170
  • [5] Performance of the APTIMA Combo 2 assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in female urine and endocervical swab specimens
    Gaydos, CA
    Quinn, TC
    Willis, D
    Weissfeld, A
    Hook, EW
    Martin, DH
    Ferrero, DV
    Schachter, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (01) : 304 - 309
  • [6] A VALIDATION STUDY OF THE GEN-PROBE APTIMA COMBO2 (AC2) ASSAY FOR DETECTING CHLAMYDIA TRACHOMATIS AND NEISSERIA GONORRHOEAE IN DRY SWABS
    Cosentino, L.
    Schwebke, J. R.
    Hobbs, M. M.
    Hillier, S. L.
    SEXUALLY TRANSMITTED INFECTIONS, 2011, 87 : A278 - A278
  • [7] Evaluation of the APTIMA COMBO GEN-PROBE technique in the diagnosis of Chlamydia trachomatis infections and interest of systematic screening for Neisseria gonorrhoeae
    Sueur, JM
    Orfila, J
    Betsou, F
    Anarratone, F
    EUROGIN 2003: 5TH INTERNATIONAL MULTIDISCIPLINARY CONGRESS, 2003, : 349 - 352
  • [8] Evaluation of the APTIMA Combo 2 assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.
    Boyadzhyan, B
    Yashina, T
    Yatabe, JAH
    Patnaik, M
    CLINICAL CHEMISTRY, 2001, 47 (11) : 2082 - 2082
  • [9] Detection and Throughput Comparison of APTIMA Combo 2 (TIGRIS) and ProbeTec ET CT/GC OX (VIPER XTR) for Chlamydia trachomatis in Self-Collected Vaginal and Urine Specimens
    Chernesky, M.
    Hatchette, T.
    Jang, D.
    Gilchrist, J.
    Smieja, M.
    Ratnam, S.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2013, 15 (06): : 883 - 883
  • [10] Confirmation of positive Gen-Probe APTIMA® Combo 2 results for Neisseria gonorrhoeae in genital swabs or first catch urine specimens
    Schachter, J.
    Donegan, E. A.
    Moncada, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2006, 8 (05): : 644 - 644