A POSITON SENSITIVE DETECTOR WITH PMT READOUT

被引:0
|
作者
Li, Jiaxing [1 ]
机构
[1] Southwest Univ, Sch Phys Sci & Technol, Chongqing 400715, Peoples R China
关键词
SCINTILLATION DETECTOR; SPECTROMETER; RESOLUTION; ASTRONOMY; CHAMBERS;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A CsI(Tl) scintillation detector with a two-dimension position-sensitive photomultiplier readout at RIBLL is developed. The position resolution of the detector was obtained with RIB N-17, and the performance of detector was simulated by using GEANT4. The simulation results accorded with the experimental ones. The reflection factor of the aluminum foil outside the scintillator plays an important role on the position resolution.
引用
收藏
页码:219 / 222
页数:4
相关论文
共 50 条
  • [1] An ellipsoidal time detector with PMT readout
    Li Jiaxing
    Liu Pingping
    Wang Jiansong
    Xiao Guoqing
    Guo Zhongyan
    Hu Zhengguo
    Mao Ruishi
    Sun Zhiyu
    Xu Hushan
    Zhan Wenlong
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2009, 20 (04) : 248 - 250
  • [2] An ellipsoidal time detector with PMT readout
    LI Jiaxing 1
    [J]. Nuclear Science and Techniques, 2009, 20 (04) : 248 - 250
  • [3] A TOF-PET prototype with position sensitive PMT readout
    Chen Jin-Da
    Xu Hu-Shan
    Hu Zheng-Guo
    Chen Ruo-Fu
    Tang Bin
    Yue Ke
    Yu Yu-Hong
    Zhang Xue-Heng
    Kong Jie
    Zang Yong-Dong
    Wang Jian-Song
    Sun Zhi-Yu
    Guo Zhong-Yan
    [J]. CHINESE PHYSICS C, 2011, 35 (01) : 61 - 66
  • [4] A TOF-PET prototype with position sensitive PMT readout
    陈金达
    徐瑚珊
    胡正国
    陈若富
    唐彬
    岳珂
    余玉洪
    章学恒
    孔洁
    臧永东
    王建松
    孙志宇
    郭忠言
    [J]. Chinese Physics C, 2011, 35 (01) : 61 - 66
  • [5] PIXELLATED CSI(TL) ARRAYS WITH POSITION-SENSITIVE PMT READOUT
    TRUMAN, A
    BIRD, AJ
    RAMSDEN, D
    HE, Z
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 375 - 378
  • [6] A front end ASIC for the readout of the PMT in the KM3NeT detector
    Gajanana, D.
    Gromov, V.
    Timmer, P.
    Heine, E.
    Kluit, R.
    [J]. JOURNAL OF INSTRUMENTATION, 2010, 5
  • [7] A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout
    Kim, Heejong
    Kao, Chien-Min
    Frisch, Henry
    Moses, William W.
    Choong, Woon-Seng
    Genat, Jean-Francois
    Tang, Fukun
    Chen, Chin-Tu
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3106 - +
  • [8] A study of liquid argon detector's n/γ discrimination capability with PMT or SiPM readout
    Chen, Y. D.
    Lei, Y.
    Wang, L.
    Guan, M. Y.
    Wang, T. A.
    Guo, C.
    Liu, J. C.
    Yang, C. G.
    Liang, X. H.
    [J]. RADIATION DETECTION TECHNOLOGY AND METHODS, 2024, 8 (02) : 1246 - 1253
  • [9] PET detector using waveshifting optical fibers and microchannel plate PMT with delay line readout
    Williams, MB
    Sealock, RM
    Majewski, S
    Weisenberger, AG
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (02) : 195 - 205
  • [10] Readout Electronics Development Based on an ASIC for PET Detector using PMT-Quadrant-Sharing
    Xu, Tianpeng
    Chen, Jing
    Lu, Lingjun
    Deng, Zhi
    Ma, Tianyu
    Wang, Shi
    Liu, Yaqiang
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 906 - 908