Ultra-high-resolution 3D imaging of atherosclerosis in mice with synchrotron differential phase contrast: a proof of concept study

被引:12
|
作者
Bonanno, Gabriele [1 ,2 ,3 ]
Coppo, Simone [1 ,2 ,3 ]
Modregger, Peter [3 ,4 ]
Pellegrin, Maxime [5 ]
Stuber, Annina [1 ,2 ,3 ]
Stampanoni, Marco [4 ,6 ,7 ]
Mazzolai, Lucia [5 ]
Stuber, Matthias [1 ,2 ,3 ]
van Heeswijk, Ruud B. [1 ,2 ,3 ]
机构
[1] Univ Hosp CHUV, Dept Radiol, Lausanne, Switzerland
[2] Univ UNIL Lausanne, Lausanne, Switzerland
[3] Ctr Biomed Imaging CIBM, Lausanne, Switzerland
[4] Paul Scherrer Inst, Swiss Light Source, Villigen, Switzerland
[5] Univ Hosp Lausanne CHUV, Div Angiol, Lausanne, Switzerland
[6] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[7] ETH, Zurich, Switzerland
来源
SCIENTIFIC REPORTS | 2015年 / 5卷
关键词
APOLIPOPROTEIN E-DEFICIENT; X-RAY MICROTOMOGRAPHY; ANIMAL-MODELS; LESIONS; RADIATION; WALL; CT;
D O I
10.1038/srep11980
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The goal of this study was to investigate the performance of 3D synchrotron differential phase contrast (DPC) imaging for the visualization of both macroscopic and microscopic aspects of atherosclerosis in the mouse vasculature ex vivo. The hearts and aortas of 2 atherosclerotic and 2 wild-type control mice were scanned with DPC imaging with an isotropic resolution of 15 m. The coronary artery vessel walls were segmented in the DPC datasets to assess their thickness, and histological staining was performed at the level of atherosclerotic plaques. The DPC imaging allowed for the visualization of complex structures such as the coronary arteries and their branches, the thin fibrous cap of atherosclerotic plaques as well as the chordae tendineae. The coronary vessel wall thickness ranged from 37.4 +/- 5.6 mu m in proximal coronary arteries to 13.6 +/- 3.3 mu m in distal branches. No consistent differences in coronary vessel wall thickness were detected between the wild-type and atherosclerotic hearts in this proof-of-concept study, although the standard deviation in the atherosclerotic mice was higher in most segments, consistent with the observation of occasional focal vessel wall thickening. Overall, DPC imaging of the cardiovascular system of the mice allowed for a simultaneous detailed 3D morphological assessment of both large structures and microscopic details.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] 3D synchrotron imaging of muscle tissues at different atrophic stages in stroke and spinal cord injury: a proof-of-concept study
    Pingel, Jessica
    Kjer, Hans Martin
    Biering-Sorensen, Fin
    Feidenhans'l, Robert
    Dyrby, Tim B.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [22] 3D synchrotron imaging of muscle tissues at different atrophic stages in stroke and spinal cord injury: a proof-of-concept study
    Jessica Pingel
    Hans Martin Kjer
    Fin Biering-Sørensen
    Robert Feidenhans’l
    Tim B. Dyrby
    Scientific Reports, 12
  • [23] 3D visualization of DCIS by high resolution synchrotron CT
    Ichihara, Shu
    Ando, Masami
    Maksimenko, Anton
    Sugivania, Hiroshi
    Hashimoto, Eiko
    Yuasa, Tetsuya
    Bando, Hiroko
    Ueno, Ei
    Yamazaki, Katsuhito
    Ohbayashi, Chiho
    Hanioka, Keisuke
    MODERN PATHOLOGY, 2006, 19 : 13 - 13
  • [24] An exploratory study of imaging diagnostic clues for overhanging facial nerve in ultra-high-resolution CT
    Zhang, Zhengyu
    Tang, Ruowei
    Wu, Qian
    Zhao, Pengfei
    Yang, Zhenghan
    Wang, Zhenchang
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2023, 280 (08) : 3643 - 3651
  • [25] An exploratory study of imaging diagnostic clues for overhanging facial nerve in ultra-high-resolution CT
    Zhengyu Zhang
    Ruowei Tang
    Qian Wu
    Pengfei Zhao
    Zhenghan Yang
    Zhenchang Wang
    European Archives of Oto-Rhino-Laryngology, 2023, 280 : 3643 - 3651
  • [26] Comparison of high-resolution synchrotron-radiation-based phase-contrast imaging and absorption-contrast imaging for evaluating microstructure of vascular networks in rat brain: from 2D to 3D views
    Li, Hong-Lei
    Ding, Hui
    Yin, Xian-Zhen
    Chen, Zhuo-Hui
    Tang, Bin
    Sun, Jing-Yan
    Hu, Xin-Hang
    Lv, Xinyi
    Kang, Shun-Tong
    Fan, Yi-Shu
    Wu, Tong
    Zhao, Song-Feng
    Xiao, Bo
    Zhang, Meng-Qi
    JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 : 2024 - 2032
  • [27] Propagation-based phase-contrast synchrotron imaging of aortic dissection in mice: from individual elastic lamella to 3D analysis
    Gerlinde Logghe
    Bram Trachet
    Lydia Aslanidou
    Pablo Villaneuva-Perez
    Julie De Backer
    Nikolaos Stergiopulos
    Marco Stampanoni
    Hiroki Aoki
    Patrick Segers
    Scientific Reports, 8
  • [28] Propagation-based phase-contrast synchrotron imaging of aortic dissection in mice: from individual elastic lamella to 3D analysis
    Logghe, Gerlinde
    Trachet, Bram
    Aslanidou, Lydia
    Villaneuva-Perez, Pablo
    De Backer, Julie
    Stergiopulos, Nikolaos
    Stampanoni, Marco
    Aoki, Hiroki
    Segers, Patrick
    SCIENTIFIC REPORTS, 2018, 8
  • [29] High-precision 3D drift correction with differential phase contrast images
    Shang, Mingtao
    Zhou, Zhiwei
    Kuang, Weibing
    Wang, Yujie
    Xin, Bo
    Huang, Zhen-Li
    OPTICS EXPRESS, 2021, 29 (21) : 34641 - 34655
  • [30] Quantitative differential phase contrast imaging at high resolution with radially asymmetric illumination
    Lin, Yu-Zi
    Huang, Kuang-Yuh
    Luo, Yuan
    OPTICS LETTERS, 2018, 43 (12) : 2973 - 2976