This paper reports on a seismic monitoring experiment conducted on the bell tower of the San Frediano Church in Lucca, Italy. The tower, dating back to the 11th century, has been fitted along its height with four triaxial seismometric stations which were then left active on the tower for four days. The data from the monitoring system have been processed via the Stochastic Subspace Identification Method, implemented in the MACEC code, which has allowed extracting the tower's natural frequencies, mode shapes and damping ratios and their variations over time. A finite element model of the structure has been created via the NOSA-ITACA code and updated to fit the experimental data. The analysis has proved the effectiveness of the tools employed to assess the dynamic behaviour of ancient masonry towers.
引用
收藏
页码:669 / 675
页数:7
相关论文
共 24 条
  • [1] Structural monitoring and assessment of an ancient masonry tower
    Invernizzi, Stefano
    Lacidogna, Giuseppe
    Lozano-Ramirez, Natalia E.
    Carpinteri, Alberto
    [J]. ENGINEERING FRACTURE MECHANICS, 2019, 210 : 429 - 443
  • [2] Ambient Vibrations of Age-old Masonry Towers: Results of Long-term Dynamic Monitoring in the Historic Centre of Lucca
    Azzara, Riccardo Mario
    Girardi, Maria
    Iafolla, Valerio
    Lucchesi, David M.
    Padovani, Cristina
    Pellegrini, Daniele
    [J]. INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2021, 15 (01) : 5 - 21
  • [3] Discontinuous approaches for nonlinear dynamic analyses of an ancient masonry tower
    Ferrante, Angela
    Loverdos, Dimitri
    Clementi, Francesco
    Milani, Gabriele
    Formisano, Antonio
    Lenci, Stefano
    Sarhosis, Vasilis
    [J]. ENGINEERING STRUCTURES, 2021, 230
  • [4] Assessment of ancient masonry slender towers under seismic loading: dynamic characterization of the Cuatrovitas tower
    Pineda, P.
    Saez, A.
    [J]. STRUCTURAL STUDIES, REPAIRS AND MAINTENANCE OF HERITAGE ARCHITECTURE XI, 2009, 109 : 615 - 629
  • [5] The influence of environmental parameters on the dynamic behaviour of the San Frediano bell tower in Lucca
    Azzara, Riccardo Mario
    De Roeck, Guido
    Girardi, Maria
    Padovani, Cristina
    Pellegrini, Daniele
    Reynders, Edwin
    [J]. ENGINEERING STRUCTURES, 2018, 156 : 175 - 187
  • [6] Ambient vibrations for the assessment of the strengthening intervention of a masonry barrel vault
    Di Primio, Alice
    Fiorini, Noemi
    Spina, Daniele
    Valente, Claudio
    Vasta, Marcello
    [J]. STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2021, 20 (03): : 1312 - 1330
  • [7] Seismic assessment of a historical masonry tower with nonlinear static and dynamic analyses tuned on ambient vibration tests
    D'Ambrisi, Angelo
    Mariani, Valentina
    Mezzi, Marco
    [J]. ENGINEERING STRUCTURES, 2012, 36 : 210 - 219
  • [8] Structural dynamic identification of a damaged and restored masonry vault using Ambient Vibrations
    Calik, Ismet
    Bayraktar, Alemdar
    Turker, Temel
    Karadeniz, Halil
    [J]. MEASUREMENT, 2014, 55 : 462 - 472
  • [9] FE MODELLING FOR SEISMIC ASSESSMENT OF AN ANCIENT TOWER FROM AMBIENT VIBRATION SURVEY
    Gentile, C.
    Saisi, A.
    Borlenghi, P.
    [J]. 8TH IOMAC INTERNATIONAL OPERATIONAL MODAL ANALYSIS CONFERENCE, 2019, : 295 - 305
  • [10] Dynamic identification of an ancient masonry bell tower using a MEMS-based acquisition system
    Bassoli, Elisa
    Vincenzi, Loris
    Bovo, Marco
    Mazzotti, Claudio
    [J]. 2015 IEEE WORKSHOP ON ENVIRONMENTAL, ENERGY AND STRUCTURAL MONITORING SYSTEMS (EESMS), 2015, : 226 - 231