Effects of thermal and mechanical cyclic loads on polyurethane pre-insulated pipes

被引:7
|
作者
Doyle, Lucia [1 ]
Weidlich, Ingo [1 ]
机构
[1] HafenCity Univ, Dept Infrastructural Engn, Uberseeallee 16, Hamburg, Germany
关键词
cyclic loading; district heating; fatigue; foam; polyurethane; sandwich structure; FATIGUE BEHAVIOR; FRACTURE-TOUGHNESS; CROSS-LINKING; FOAM; FAILURE; TEMPERATURE; SHEAR;
D O I
10.1111/ffe.13347
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
District heating (DH) pre-insulated pipes are a sandwich assembly composed by a steel heat service pipe, polyurethane (PU) foam and polyethylene casing. The foam acts as bond between the steel pipe and casing. The application has high constraints for the foam, as it is subjected to cyclic multiaxial stresses, high cyclic temperatures and long expected service life. In this study, we evaluate if and how cyclic loads affect the shear strength, shear modulus, toughness and failure behaviour of the PU foam in DH pipes sandwich assembly compared with unaged reference samples. We have found that the simultaneous application of mechanical and thermal loads weakens the strength and increases the stiffness of the foam and that this change is not caused by degradation of the molecular structure. Crack initiation and propagation along the pipe samples follow a very consistent pattern between samples, with cracks initiating in Mode II and propagating in Mode I. The consistent axial displacement of approximately 2 cm from each other suggests the formation of strain localizations.
引用
收藏
页码:156 / 168
页数:13
相关论文
共 50 条
  • [1] Anisotropy in Polyurethane Pre-Insulated Pipes
    Doyle, Lucia
    Weidlich, Ingo
    Illguth, Marcus
    [J]. POLYMERS, 2019, 11 (12)
  • [2] Life-time of pre-insulated pipes
    Larsen, Christian Ting
    [J]. Euroheat and Power/Fernwarme International, 2003, 32 (06):
  • [3] Optimization of Geometric Parameters of Thermal Insulation of Pre-Insulated Double Pipes
    Krawczyk, Dorota Anna
    Teleszewski, Tomasz Janusz
    [J]. ENERGIES, 2019, 12 (06)
  • [4] Analysis of "Conti" Pre-insulated Pipes with Diffusion Barrier Versus Traditional Pre-insulated Pipes Used in District Heating Networks
    Lefter, Razvan -Corneliu
    Popescu, Daniela
    [J]. PROCEEDINGS OF THE 2012 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE 2012), 2012, : 978 - 983
  • [5] Pre-insulated pipes for Samsung LNG tankers
    不详
    [J]. NAVAL ARCHITECT, 2003, : 35 - 35
  • [6] Remaining useful life of pre-insulated bonded pipes
    Hoffmann, Heinz-Werner
    Grage, Thomas
    Röse, Alexander
    [J]. Euroheat and Power/Fernwarme International, 2002, 31 (03): : 72 - 76
  • [7] Analysis of thermal insulation of pre-insulated triple pipes-preliminary numerical tests
    Teleszewski, T.J.
    Krawczyk, D.A.
    Rodero, A.
    [J]. Renewable Energy and Power Quality Journal, 2020, 18 : 522 - 525
  • [8] Effects of cyclic mechanical loads and thermal ageing on district heating pipes
    Vega, Alberto
    Yarahmadi, Nazdaneh
    Sallstrom, Jan Henrik
    Jakubowicz, Ignacy
    [J]. POLYMER DEGRADATION AND STABILITY, 2020, 182
  • [9] Pre-insulated pipes with casings of recycled HDPE from external sources
    Jorsal, Peter
    [J]. Euroheat and Power/Fernwarme International, 2021, 50 (4-5): : 28 - 31
  • [10] Pre-insulated pipes with casings of recycled HDPE from external sources
    Jorsal, Peter
    [J]. Euroheat and Power (English Edition), 2020, 2020 (04): : 40 - 43