Ultrasound guidance compared with electrical neurostimulation for peripheral nerve block: a systematic review and meta-analysis of randomized controlled trials

被引:298
|
作者
Abrahams, M. S. [1 ]
Aziz, M. F. [1 ]
Fu, R. F. [1 ]
Horn, J. -L. [1 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Anesthesiol & Perioperat Med, Portland, OR 97239 USA
关键词
anaesthetic techniques; regional; neuromuscular transmission; ultrasound; nerve stimulation; BRACHIAL-PLEXUS ANESTHESIA; ULTRASONOGRAPHIC GUIDANCE; AXILLARY BLOCK; INJECTION TECHNIQUE; MOTOR RESPONSE; SUCCESS RATE; ONSET TIME; IMPROVES; STIMULATION; SINGLE;
D O I
10.1093/bja/aen384
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Despite the growing interest in the use of ultrasound (US) imaging to guide performance of regional anaesthetic procedures such as peripheral nerve blocks, controversy still exists as to whether US is superior to previously developed nerve localization techniques such as the use of a peripheral nerve stimulator (PNS). We sought to clarify this issue by performing a systematic review and meta-analysis of all randomized controlled trials that have compared these two methods of nerve localization. We searched Ovid MEDLINE (R), the Cochrane Central Register of Controlled Trials (R), and Google Scholar databases and also the reference lists of relevant publications for eligible studies. A total of 13 studies met our criteria and were included for analysis. Studies were rated for methodological quality by two reviewers. Data from these studies were abstracted and synthesized using a meta-analysis. Blocks performed using US guidance were more likely to be successful [risk ratio (RR) for block failure 0.41, 95% confidence interval (CI) 0.26-0.66, P < 0.001], took less time to perform (mean 1 min less to perform with US, 95% CI 0.4-1.7 min, P=0.003), had faster onset (29% shorter onset time, 95% CI 45-12%, P=0.001), and had longer duration (mean difference 25% longer, 95% CI 12-38%, P < 0.001) than those performed with PNS guidance. US guidance also decreased the risk of vascular puncture during block performance (RR 0.16, 95% CI 0.05-0.47, P=0.001). US improves efficacy of peripheral nerve block compared with techniques that utilize PNS for nerve localization. Larger studies are needed to determine whether or not the use of US can decrease the number of complications such as nerve injury or systemic local anaesthetic toxicity.
引用
收藏
页码:408 / 417
页数:10
相关论文
共 50 条
  • [1] Continuous Peripheral Nerve Block Compared With Single-Injection Peripheral Nerve Block A Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Bingham, Ann E.
    Fu, Rochelle
    Horn, Jean-Louis
    Abrahams, Matthew S.
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2012, 37 (06) : 583 - 594
  • [2] Ultrasound compared with nerve stimulation guidance for peripheral nerve catheter placement: a meta-analysis of randomized controlled trials
    Schnabel, A.
    Meyer-Friessem, C. H.
    Zahn, P. K.
    Pogatzki-Zahn, E. M.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (04) : 564 - 572
  • [3] Efficacy of Ultrasound and Nerve Stimulation Guidance in Peripheral Nerve Block: A Systematic Review and Meta-Analysis
    Wang, Zhi-Xue
    Zhang, De-Li
    Liu, Xin-Wei
    Li, Yan
    Zhang, Xiao-Xia
    Li, Ru-Hong
    IUBMB LIFE, 2017, 69 (09) : 720 - 734
  • [4] Ultrasound Guidance in Femoral Artery Catheterization: A Systematic Review and a Meta-Analysis of Randomized Controlled Trials
    Rashid, Mohammed K.
    Sahami, Nazanin
    Singh, Kuljit
    Winter, Jose
    Sheth, Tej
    Jolly, Sanjit S.
    JOURNAL OF INVASIVE CARDIOLOGY, 2019, 31 (07): : E192 - +
  • [5] Ultrasound guidance during embryo transfer: a systematic review and meta-analysis of randomized controlled trials
    Teixeira, D. M.
    Dassuncao, L. A.
    Vieira, C. V. R.
    Barbosa, M. A. P.
    Coelho Neto, M. A.
    Nastri, C. O.
    Martins, W. P.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 45 (02) : 139 - 148
  • [6] Systematic Review and Meta-Analysis of Randomized Controlled Trials for Scalp Block in Craniotomy
    Duda, Taylor
    Lannon, Melissa
    Gandhi, Pranjan
    Martyniuk, Amanda
    Farrokhyar, Forough
    Sharma, Sunjay
    NEUROSURGERY, 2023, 93 (01) : 4 - 23
  • [7] Ultrasound guidance versus classical method for intrauterine insemination: A systematic review and meta-analysis of randomized controlled trials
    Baradwan, Saeed
    Alshahrani, Majed Saeed
    Miski, Najlaa Talat
    Alkhamis, Waleed H.
    Alfaifi, Suhail S.
    Abdelhakim, Ahmed Mohamed
    Sunoqrot, Mohammad
    Ahmaro, Manar
    Abdelazem, Osama
    Mohammed, Ahmed Hashim
    Abbas, Ahmed M.
    Bakry, Mohamed Sobhy
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2021, 263 : 223 - 230
  • [8] Efficacy of neurostimulation across mental disorders: systematic review and meta-analysis of 208 randomized controlled trials
    Joshua Hyde
    Hannah Carr
    Nicholas Kelley
    Rose Seneviratne
    Claire Reed
    Valeria Parlatini
    Matthew Garner
    Marco Solmi
    Stella Rosson
    Samuele Cortese
    Valerie Brandt
    Molecular Psychiatry, 2022, 27 : 2709 - 2719
  • [9] Efficacy of neurostimulation across mental disorders: systematic review and meta-analysis of 208 randomized controlled trials
    Hyde, Joshua
    Carr, Hannah
    Kelley, Nicholas
    Seneviratne, Rose
    Reed, Claire
    Parlatini, Valeria
    Garner, Matthew
    Solmi, Marco
    Rosson, Stella
    Cortese, Samuele
    Brandt, Valerie
    MOLECULAR PSYCHIATRY, 2022, 27 (06) : 2709 - 2719
  • [10] Ultrasound for monitoring controlled ovarian stimulation: a systematic review and meta-analysis of randomized controlled trials
    Martins, W. P.
    Vieira, C. V. R.
    Teixeira, D. M.
    Barbosa, M. A. P.
    Dassuncao, L. A.
    Nastri, C. O.