Spectrally-dependent Z-scan measurement of the nonlinear refractive index of Graphene

被引:0
|
作者
Thakur, Siddharatha [1 ]
Semnani, Behrooz [1 ]
Majedi, Amir Hamed [2 ]
机构
[1] Univ Waterloo, Waterloo Inst Nanotechnol, Elect & Comp Engn, Waterloo, ON, Canada
[2] Univ Waterloo, Waterloo Inst Nanotechnol, Elect & Comp Engn, Phys & Astron, Waterloo, ON, Canada
来源
关键词
graphene; nonlinear optics; nonlinear refractive index;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The nonlinear optical behaviour of Graphene has become an important topic of investigation as it adds another facet to its growing list of electronic and mechanical properties. This work investigates the spectral dependence of the nonlinear index of refraction (n(2)) of graphene, spanning excitation in the 800 1050 nm range, using the Z-Scan technique.
引用
收藏
页数:1
相关论文
共 50 条
  • [1] Z-scan measurement of the nonlinear refractive index of graphene
    Zhang, Han
    Virally, Stephane
    Bao, Qiaoliang
    Ping, Loh Kian
    Massar, Serge
    Godbout, Nicolas
    Kockaert, Pascal
    OPTICS LETTERS, 2012, 37 (11) : 1856 - 1858
  • [2] Measurement of nonlinear refractive index in open aperture Z-scan
    Das, Ritwick
    Shukla, Mukesh Kumar
    2013 Workshop on Recent Advances in Photonics (WRAP), 2013,
  • [3] Measurement of the nonlinear refractive index of polydiacetylene using Michelson interferometry and z-scan
    Quintero-Torres, R
    Thakur, M
    JOURNAL OF APPLIED PHYSICS, 1999, 85 (01) : 401 - 403
  • [4] Measurement of nonlinear refractive index by time-resolved z-scan technique
    Kawazoe, T
    Kawaguchi, H
    Inoue, J
    Haba, O
    Ueda, M
    OPTICS COMMUNICATIONS, 1999, 160 (1-3) : 125 - 129
  • [5] Measurement of nonlinear refractive index in open-aperture Z-scan experiments
    Das, Ritwick
    Shukla, Mukesh Kumar
    PRAMANA-JOURNAL OF PHYSICS, 2014, 83 (06): : 985 - 994
  • [6] Z-scan measurement of the nonlinear refractive index of monolayer WS2
    Zheng, Xin
    Zhang, Yangwei
    Chen, Runze
    Cheng, Xiang'ai
    Xu, Zhongjie
    Jiang, Tian
    OPTICS EXPRESS, 2015, 23 (12): : 15616 - 15623
  • [7] Measurement of nonlinear refractive index in open-aperture Z-scan experiments
    RITWICK DAS
    MUKESH KUMAR SHUKLA
    Pramana, 2014, 83 : 985 - 994
  • [8] Z-scan measurement of the refractive index of graphene (vol 37, pg 1856, 2012)
    Zhang, Han
    Virally, Stephane
    Bao, Qiaoliang
    Ping, Loh Kian
    Massar, Serge
    Godbout, Nicolas
    Kockaert, Pascal
    OPTICS LETTERS, 2013, 38 (09) : 1566 - 1566
  • [9] Combination of muller matrix polarimetry and z-scan techniques for nonlinear refractive index measurement
    Alsaedi, Khitam
    Madanipour, Khosro
    OPTICS AND LASERS IN ENGINEERING, 2023, 168
  • [10] Limits to the determination of the nonlinear refractive index by the Z-scan method
    de Nalda, R
    del Coso, R
    Requejo-Isidro, J
    Olivares, J
    Suarez-Garcia, A
    Solis, J
    Afonso, CN
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2002, 19 (02) : 289 - 296