A spectral-domain optical coherence tomography device provides reliable corneal pachymetry measurements in canine eyes

被引:12
|
作者
Alario, A. F. [1 ]
Pirie, C. G. [1 ]
机构
[1] Tufts Cummings Sch Vet Med, Dept Clin Sci, North Grafton, MA 01536 USA
关键词
ULTRASONIC PACHYMETRY; POSTERIOR SEGMENT; SD-OCT; THICKNESS; ANTERIOR; DOGS; KERATITIS; NERVE;
D O I
10.1136/vr.101530
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The objective of this study was to determine central corneal thickness (CCT) and the intra-and interuser reliability using a portable spectral-domain optical coherence tomography (SD-OCT) device in canine eyes. Twenty clinically normal dogs were examined. CCT measurements were obtained from both eyes of each animal three times by two operators in succession. The CCT was automatically calculated using the pachymetry software generated from eight radial scans, 6 mm in length. Mean canine CCT was 606.83 +/- 39.45 mu m for all eyes examined. There was no significant difference in CCT based on the eye examined (OD vs OS), age or gender of the animal. There was no significant difference in CCT between replicates performed by the same operator; however, a small but significant difference was noted in CCT between operators. The mean difference in CCT between operators was 1.9 mu m (P=0.03). The coefficient of variation for each user and between users was very low (range 0.64-1.7 per cent). The intraclass correlation coefficient comparing operators was 0.975. Based on these results, the SD-OCT device evaluated is capable of obtaining precise CCT measurements with excellent intra- and interoperator reliability in canine eyes.
引用
收藏
页码:605 / +
页数:4
相关论文
共 50 条
  • [1] Manual corneal thickness measurements of healthy equine eyes using a portable spectral-domain optical coherence tomography device
    Pirie, C. G.
    Alario, A. F.
    Barysauskas, C. M.
    Gradil, C.
    Uricchio, C. K.
    EQUINE VETERINARY JOURNAL, 2014, 46 (05) : 631 - 634
  • [2] Intraoperative Pachymetry Using Spectral-Domain Optical Coherence Tomography during Accelerated Corneal Collagen Crosslinking
    Chow, Vanissa W. S.
    Biswas, Sayantan
    Yu, Marco
    Wong, Victoria W. Y.
    Jhanji, Vishal
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [3] Reliability of manual measurements of corneal thickness obtained from healthy canine eyes using spectral-domain optical coherence tomography (SD-OCT)
    Alario, Anthony F.
    Pirie, Christopher G.
    CANADIAN JOURNAL OF VETERINARY RESEARCH-REVUE CANADIENNE DE RECHERCHE VETERINAIRE, 2014, 78 (03): : 221 - 225
  • [4] Repeatability of corneal pachymetry and epithelial thickness measurements with spectral-domain optical coherence tomography (SD-OCT) and correlation to ocular surface parameters
    Vasileia Chatzistergiou
    Argyrios Tzamalis
    Asterios Diafas
    Eirini Oustoglou
    Asimina Mataftsi
    Ioannis Tsinopoulos
    Nikolaos Ziakas
    International Ophthalmology, 2023, 43 : 3139 - 3148
  • [5] Spectral-Domain Optical Coherence Tomography Findings of Eyes With Macular Telangiectasia
    Prabakaran, S. L.
    Wafapoor, H.
    Prabakaran, S.
    Eaton, A. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [6] Repeatability of corneal pachymetry and epithelial thickness measurements with spectral-domain optical coherence tomography (SD-OCT) and correlation to ocular surface parameters
    Chatzistergiou, Vasileia
    Tzamalis, Argyrios
    Diafas, Asterios
    Oustoglou, Eirini
    Mataftsi, Asimina
    Tsinopoulos, Ioannis
    Ziakas, Nikolaos
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (09) : 3139 - 3148
  • [7] The Repeatability of Retinal Layer Thickness Measurements with Spectral-Domain Optical Coherence Tomography in Normal Eyes
    Kang, Min Seok
    Yu, Seung-Young
    Kwak, Hyung Woo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (05): : 786 - 793
  • [8] Artifacts in Spectral-Domain Optical Coherence Tomography Measurements in Glaucoma
    Asrani, Sanjay
    Essaid, Luma
    Alder, Brian D.
    Santiago-Turla, Cecilia
    JAMA OPHTHALMOLOGY, 2014, 132 (04) : 396 - 402
  • [9] Assessment of corneal layers thickness with spectral-domain optical coherence tomography
    Segura, F.
    de la Fuente, C. Lopez
    Sachez-Cano, A.
    Orduna, E.
    Del Buey, M.
    Pinilla, I.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [10] Corneal Thickness Measurements Using 2 Kinds of Spectral Domain Optical Coherence Tomography, Pentacam, Ultrasound Pachymetry
    Cheong, Yu Jin
    Lee, Bo Ram
    Han, Kyung Eun
    Jun, Roo Min
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (10): : 1527 - 1534