Driver ECG Measuring System With a Conductive Fabric-Based Dry Electrode

被引:24
|
作者
Choi, You-Jun [1 ]
Lee, Jae-Yeol [2 ]
Kong, Seung-Hyun [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Cho Chun Shik Grad Sch Green Transportat, Daejeon 34141, South Korea
[2] Hwajin Corp, Yeongcheon 38898, South Korea
来源
IEEE ACCESS | 2018年 / 6卷
关键词
Conductive fabric; dry electrode; driver monitoring system; contact-based ECG measuring system; ECG signals; conductive fabric shaping; steering wheel; smart car; ENHANCEMENT; SENSOR; DESIGN;
D O I
10.1109/ACCESS.2017.2766098
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The dry electrodes that the automotive manufacturers use to measure electrocardiogram (ECG) signals for driver status monitoring have three technical problems: a lack of attachment flexibility, low ECG signal detection stability, and the potential to harm or irritate the driver. In addition, the complicated signal-conditioning circuits employed by automotive manufacturers to improve the SNR, increase the ECG signal detection stability, and to ensure a wider dynamic range of the electrodes increase the cost and complexity of driver ECG measuring systems. In this paper, we propose a driver ECG measuring system that resolves these three technical issues using a steering wheel covered with a conductive fabric-based dry electrode material, which is manufactured by an electroplating method. In addition, we employ a conductive fabric-shaping procedure in the development of the fabric-based dry electrode to improve the attachment flexibility and to reduce the cost and complexity of the required signal-conditioning circuit. We verify the ECG signal-measuring performance of the proposed system by comparing it with ECG signal measurement results from a clinical ECG monitoring system. In addition, despite applying a simpler signal conditional circuit than those used in conventional ECG measuring systems, we verify that the proposed system achieves higher SNR and ECG signal detection stability than conventional ECG measuring systems through various field tests in actual driving environments.
引用
收藏
页码:415 / 427
页数:13
相关论文
共 50 条
  • [1] A Wireless Monitoring System for Measuring Flexible Tank Strain Using Fabric-Based Stretchable Conductive Sensor
    Razif, Muhammad Rusydi Muhammad
    Jaafar, Nur Jannah
    Mustapha, Nurul Hasyimah Mohd
    Mi, Yong Tze
    Shah, Nor Shahida Mohd
    Hashim, Muhamad Mohshein
    Mustafa, Khairul Nizam
    9TH INTERNATIONAL CONFERENCE ON MECHATRONICS ENGINEERING, ICOM 2024, 2024, : 133 - 138
  • [2] Fabrication of conductive fabric as textile electrode for ECG monitoring
    Yun Zhou
    Xin Ding
    Jingwei Zhang
    Yaru Duan
    Jiyong Hu
    Xudong Yang
    Fibers and Polymers, 2014, 15 : 2260 - 2264
  • [3] Fabrication of Conductive Fabric as Textile Electrode for ECG Monitoring
    Zhou, Yun
    Ding, Xin
    Zhang, Jingwei
    Duan, Yaru
    Hu, Jiyong
    Yang, Xudong
    FIBERS AND POLYMERS, 2014, 15 (11) : 2260 - 2264
  • [4] An ECG Monitoring System Using Conductive Fabric
    Taji, Bahareh
    Shirmohammadi, Shervin
    Groza, Voieu
    Bolic, Miodrag
    2013 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS PROCEEDINGS (MEMEA), 2013, : 309 - 314
  • [5] Mathematical model of conductive fabric-based flexible pressure sensor
    Chipot, Michel
    Lee, Kyounghun
    Seo, Jin Keun
    APPLIED MATHEMATICAL MODELLING, 2017, 48 : 775 - 786
  • [6] Wearable band using a fabric-based sensor for exercise ECG monitoring
    Shen, Chien-Lung
    Kao, Tsair
    Huang, Ching-Tang
    Lee, Jun-huei
    TENTH IEEE INTERNATIONAL SYMPOSIUM ON WEARABLE COMPUTERS, PROCEEDINGS, 2006, : 143 - +
  • [7] Conductive Fabric-Based Stretchable Hybridized Nanogenerator for Scavenging Biomechanical Energy
    Zhang, Kewei
    Wang, Zhong Lin
    Yang, Ya
    ACS NANO, 2016, 10 (04) : 4728 - 4734
  • [8] Evaluation of a Combined Conductive Fabric-Based Suspender System and Machine Learning Approach for Human Activity Recognition
    Mani, Neelakandan
    Haridoss, Prathap
    George, Boby
    IEEE OPEN JOURNAL OF INSTRUMENTATION AND MEASUREMENT, 2023, 2
  • [9] Fabric-Based Wearable Dry Electrodes for Body Surface Biopotential Recording
    Yokus, Murat A.
    Jur, Jesse S.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (02) : 423 - 430
  • [10] Fabric-based lamina emergent MXene-based electrode for electrophysiological monitoring
    Lee, Sanghyun
    Ho, Dong Hae
    Jekal, Janghwan
    Cho, Soo Young
    Choi, Young Jin
    Oh, Saehyuck
    Choi, Yoon Young
    Lee, Taeyoon
    Jang, Kyung-In
    Cho, Jeong Ho
    NATURE COMMUNICATIONS, 2024, 15 (01)