Limitations of a calibrated, quantitative APC-R assay under routine conditions

被引:3
|
作者
Jilma-Stohlawetz, Petra [1 ]
Lysy, Katharina [1 ]
Sunder-Plassmann, Raute [1 ]
Belik, Sabine [1 ]
Jilma, Bernd [2 ]
Pabinger, Ingrid [3 ]
Quehenberger, Peter [1 ]
机构
[1] Med Univ Vienna, Dept Lab Med, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Med Univ Vienna, Dept Clin Pharmacol, Vienna, Austria
[3] Med Univ Vienna, Div Haematol & Haemostaseol, Dept Med 1, Vienna, Austria
关键词
APC‐ R; DOAC; DOAC‐ Stop; factor V deficiency; lupus anticoagulant; ACTIVATED PROTEIN-C; FACTOR-V-LEIDEN; DIRECT ORAL ANTICOAGULANTS; LABORATORY ASSESSMENT; RESISTANCE; THROMBOPHILIA; UPDATE; PLASMA;
D O I
10.1111/ijlh.13378
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The aim of this study was to evaluate the Hemoclot Quanti. V-L assay in various clinical conditions. Methods We compared the Hemoclot Quanti.V-L assay with DNA testing and with the Pefakit assay in 60 normal (no mutation) vs carriers of the factor V (FV) Leiden mutation (56 heterozygous and three homozygous). We further investigated the interference of lupus anticoagulant on test results in normal and heterozygous individuals and of direct oral anticoagulants (DOACs) at trough and peak levels. Additionally, DOAC-Remove was tested in samples containing DOACs at peak levels. We further evaluated the influence of FV deficiency on this quantitative assay. Results There was a 100% agreement between the Quant. V-L assay and DNA testing in 60 normal individuals. However, 1.85% of heterozygous and 33% of homozygous samples were falsely classified with the quantitative assay, and no misclassification was observed with the Pefakit assay. Lupus anticoagulant did not influence the test results of the quantitative assay. DOACs also interfered with test results in heterozygous patients, but this effect was prevented with the DOAC-Remove procedure. Even mild FV deficiency affected the test results of the quantitative assay in heterozygous patients leading either to misclassification or the need for subsequent PCR testing. Conclusion The quantitative FV-L assay has several limitations, especially FV deficiency and the presence of DOACs have to be ruled out before running this quantitative assay.
引用
收藏
页码:318 / 323
页数:6
相关论文
共 18 条
  • [1] Further experience with the TF-based FV assay for APC resistant FVa (APC-R)
    Le, DT
    Donnelly, K
    Sevilla, B
    Rapaport, SI
    BLOOD, 1995, 86 (10) : 796 - 796
  • [2] Development and evaluation of a new activated protein C resistance assay: Staclot APC-R
    VanDreden, P
    Thuillier, N
    Amiral, J
    Bouye, M
    Martinoli, JL
    THROMBOSIS AND HAEMOSTASIS, 1997, : PS77 - PS77
  • [3] Clinical evaluation of a new functional, plasma-based assay for the detection of Factor V Leiden -: the pefalkit® APC-R Factor v Leiden assay.
    Hoppensteadt, DA
    Cunanan, J
    Walenga, JM
    Fareed, J
    Wilmer, M
    Janssen, M
    BLOOD, 2004, 104 (11) : 85B - 85B
  • [4] A quantitative study of human mastication under routine conditions.
    Cianfarani, T
    Gerstner, GE
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 837 - 837
  • [5] The Performance of a Sperm Chromatin Structure Assay (SCSA) Under Routine Conditions
    Wakefield, Penelope
    Moska, Natalie
    Murray, Elaine
    Matson, Phillip
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2010, 50 : 45 - 45
  • [6] ASSESSMENT UNDER ROUTINE CONDITIONS OF AN IMMUNOELECTROPHORETIC ASSAY FOR THYROXINE-BINDING GLOBULIN
    ATTWOOD, EC
    PROBERT, DE
    CLINICAL BIOCHEMISTRY, 1978, 11 (06) : 226 - 229
  • [7] Comparative evaluation under routine conditions of the nitrate reduction assay, the proportion assay and the MGIT 960 assay for drug susceptibility testing of clinical isolates of Mycobacterium tuberculosis
    Fonseca, Leila de Souza
    de Oliveira Vieira, Gisele Betzler
    Sobral, Luciana Fonseca
    Ribeiro, Elizabete Oliveira
    Marsico, Anna Grazia
    MEMORIAS DO INSTITUTO OSWALDO CRUZ, 2012, 107 (01): : 142 - 144
  • [8] EVALUATION OF THE CREATININE ASSAY ON THE REFLOTRON(R) ANALYZER UNDER CENTRALIZED AND NON-CENTRALIZED CONDITIONS
    DOLS, JLS
    SANDERS, GTB
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1993, 31 (06): : 359 - 366
  • [9] Xpert (R) MTB/RIF under routine conditions in diagnosing pulmonary tuberculosis: a study in two hospitals in Pakistan
    Shah, S. K.
    Kumar, A. M. V.
    Dogar, O. F.
    Khan, M. A.
    Qadeer, E.
    Tahseen, S.
    Masood, F.
    Chandio, A. K.
    Edginton, M. E.
    PUBLIC HEALTH ACTION, 2013, 3 (01): : 20 - 22
  • [10] Implementation of a flow-cytometric assay for rapid detection of HPA-1-compatible platelet donors under routine conditions
    Ostendorf, N
    Stahl, D
    Sibrowski, W
    INFUSION THERAPY AND TRANSFUSION MEDICINE-INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 2002, 29 (01): : 6 - 10