Detecting Myocardial Ischemia at Rest With Cardiac Phase-Resolved Blood Oxygen Level-Dependent Cardiovascular Magnetic Resonance

被引:27
|
作者
Tsaftaris, Sotirios A. [1 ,2 ,4 ,5 ]
Zhou, Xiangzhi [1 ]
Tang, Richard [6 ]
Li, Debiao [1 ,3 ,6 ]
Dharmakumar, Rohan [1 ,3 ,6 ]
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Elect Engn & Comp Sci, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
[4] IMT Inst Adv Studies Lucca, Piazza S Ponziano, Lucca, Italy
[5] Ist Italiano Tecnol, NEST, Ctr Nanotechnol Innovat, Pisa, Italy
[6] Cedars Sinai Med Ctr, Biomed Imaging Res Inst, Dept Biomed Sci, Los Angeles, CA 90048 USA
基金
美国国家卫生研究院;
关键词
acute coronary syndrome; BOLD MRI; coronary artery disease; ischemia; STATE FREE PRECESSION; ACUTE CORONARY SYNDROME; STEADY-STATE; VOLUME; INFARCTION; STENOSIS; EDEMA; QUANTIFICATION; STRESS; HEART;
D O I
10.1161/CIRCIMAGING.112.976076
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Fast noninvasive identification of ischemic territories at rest (before tissue-specific changes) and assessment of functional status can be valuable in the management of severe coronary artery disease. This study investigated the use of cardiac phase-resolved blood oxygen level-dependent (CP-BOLD) cardiovascular magnetic resonance in detecting myocardial ischemia at rest secondary to severe coronary artery stenosis. Methods and Results-CP-BOLD, standard cine, and T2-weighted images were acquired in canines (n=11) at baseline and within 20 minutes of ischemia induction (severe left anterior descending stenosis) at rest. After 3 hours of ischemia, left anterior descending stenosis was removed, and T2-weighted and late-gadolinium-enhancement images were acquired. From standard cine and CP-BOLD images, end-systolic and end-diastolic myocardium was segmented. Affected and remote sections of the myocardium were identified from postreperfusion late-gadolinium-enhancement images. Systolic-to-diastolic ratio (S/D), quotient of mean end-systolic and end-diastolic signal intensities (on CP-BOLD and standard cine), was computed for affected and remote segments at baseline and ischemia. Ejection fraction and segmental wall thickening were derived from CP-BOLD images at baseline and ischemia. On CP-BOLD images, S/D was >1 (remote and affected territories) at baseline; S/D was diminished only in affected territories during ischemia, and the findings were statistically significant (ANOVA, post hoc P<0.01). The dependence of S/D on ischemia was not observed in standard cine images. Computer simulations confirmed the experimental findings. Receiver-operating characteristic analysis showed that S/D identifies affected regions with performance (area under the curve, 0.87) similar to ejection fraction (area under the curve, 0.89) and segmental wall thickening (area under the curve, 0.75). Conclusions-Preclinical studies and computer simulations showed that CP-BOLD cardiovascular magnetic resonance could be useful in detecting myocardial ischemia at rest. Patient studies are needed for clinical translation.
引用
收藏
页码:311 / 319
页数:9
相关论文
共 50 条
  • [1] Detecting Myocardial Ischemic Territories in the Setting of Acute Coronary Obstructions at Rest with Cardiac Phase-Resolved Blood Oxygen Level Dependent (CP-BOLD) MRI
    Tsaftaris, Sotirios
    Zhou, Xiangzhi
    Tang, Richard
    Li, Debiao
    Dharmakumar, Rohan
    CIRCULATION, 2011, 124 (21)
  • [2] Assessment of myocardial perfusion reserve with blood oxygen level-dependent cardiovascular magnetic resonance imaging
    Jacqueline A Flewitt
    Matthias Vöhringer
    Jordin Green
    Matthias Friedrich
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [3] Blood oxygen level-dependent and perfusion magnetic resonance imaging: detecting differences in oxygen bioavailability and blood flow in transplanted kidneys
    Sadowski, Elizabeth A.
    Djamali, Arjang
    Wentland, Andrew L.
    Muehrer, Rebecca
    Becker, Bryan N.
    Grist, Thomas M.
    Fain, Sean B.
    MAGNETIC RESONANCE IMAGING, 2010, 28 (01) : 56 - 64
  • [4] Detection of acute renal ischemia in swine using blood oxygen level-dependent magnetic resonance imaging
    Alford, SK
    Sadowski, EA
    Unal, O
    Polzin, JA
    Consigny, DW
    Korosec, FR
    Grist, TM
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (03) : 347 - 353
  • [5] Dictionary-Driven Ischemia Detection From Cardiac Phase-Resolved Myocardial BOLD MRI at Rest
    Bevilacqua, Marco
    Dharmakumar, Rohan
    Tsaftaris, Sotirios A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (01) : 282 - 293
  • [6] Cardiovascular Magnetic Resonance for Visualization of Myocardial Ischemia at Rest
    Glaveckaite, Sigita
    Palionis, Darius
    Valeviciene, Nomeda Rima
    Bilkis, Valdas
    Aganauskiene-Burkuviene, Jurate
    Serpytis, Pranas
    Laucevicius, Aleksandras
    MEDICINA-LITHUANIA, 2011, 47 (09): : 494 - 496
  • [7] Blood oxygen level-dependent magnetic resonance imaging in patients with dypiridamole induced ischemia; A PET comparative study
    Egred, M
    Waiter, G
    Redpath, T
    Semple, S
    Al-Mahammad, A
    Norton, M
    Metcalfe, M
    Walton, S
    HEART, 2006, 92 : A103 - A103
  • [8] 2132 Assessment of myocardial oxygenation in the canine heart using blood oxygen level-dependent magnetic resonance imaging
    Matthias Voehringer
    Jordin D Green
    Jacqueline A Flewitt
    Cheryl A Meek
    Matthias G Friedrich
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [9] Detecting Blood Oxygen Level-Dependent (BOLD) Contrast in the Breast
    Rakow-Penner, Rebecca
    Daniel, Bruce
    Glover, Gary H.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (01) : 120 - 129
  • [10] Blood oxygen level-dependent (BOLD) magnetic resonance imaging in patients with dypiridamole induced ischemia; a PET comparative study
    Egred, M.
    Waiter, G. D.
    Semple, S. I. K.
    Redpath, T. W.
    Al-Mohammad, A.
    Norton, M. Y.
    Metcalfe, M. J.
    Walton, S.
    EUROPEAN HEART JOURNAL, 2006, 27 : 415 - 416