Accuracy of a Three-Dimensional (3D)-Printed Patient-Specific (PS) Femoral Osteotomy Guide: A Computed Tomography (CT) Study

被引:2
|
作者
Moralidou, Maria [1 ]
Di Laura, Anna [2 ,3 ]
Henckel, Johann [2 ]
Hothi, Harry [2 ,3 ]
Hart, Alister James [1 ]
机构
[1] UCL, Inst Orthopaed & Musculoskeletal Sci, London HA7 4LP, England
[2] Royal Natl Orthopaed Hosp NHS Trust, Brockley Hill, Stanmore HA7 4LP, England
[3] UCL, Dept Mech Engn, London WC1E 7JE, England
来源
BIOENGINEERING-BASEL | 2022年 / 9卷 / 11期
关键词
3D-printed patient-specific guides; total hip arthroplasty; femoral neck osteotomy;
D O I
10.3390/bioengineering9110667
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Femoral neck osteotomy creates a critical anatomical landmark for surgeons performing primary Total Hip Arthroplasty (THA); it affects the final height and position of the femoral component. Patient Specific Instrumentation (PSI) has been developed to guide the osteotomy. We aimed to assess the accuracy of a patient-specific (PS) femoral osteotomy guide in primary THA using three-dimensional (3D) computed tomography (CT) analysis. We included pre- and post-operative CT data of 103 THAs. All patients underwent 3D planning to define the optimal femoral neck osteotomy level. Our primary objective was to quantify the discrepancy between the achieved and planned osteotomy level; our secondary objective was to evaluate the clinical outcome. The median (Interquartile Range-IQR) discrepancy between the achieved and planned osteotomy level was 0.3 mm (-1 mm to 2 mm). We found a strong positive correlation between the planned and achieved osteotomy level (R-2 = 0.9, p < 0.001). A satisfactory clinical outcome was recorded. Our findings suggest that surgeons can use 3D-printed PS guides to achieve a femoral neck osteotomy with a high level of accuracy to the plan.
引用
下载
收藏
页数:12
相关论文
共 50 条
  • [1] Accuracy of intertrochanteric osteotomy for patients with slipped capital femoral epiphysis operated with 3D printed patient-specific guides
    M. van den Boorn
    J. G. G. Dobbe
    V. Lagerburg
    M. M. E. H. Witbreuk
    G. J. Streekstra
    Journal of Orthopaedic Surgery and Research, 19 (1)
  • [2] Accuracy of patient-specific three-dimensional-printed osteotomy and reduction guides for distal femoral osteotomy in dogs with medial patella luxation
    Hall, Emma L.
    Baines, Stephen
    Bilmont, Alexis
    Oxley, Bill
    VETERINARY SURGERY, 2019, 48 (04) : 584 - 591
  • [3] Three-dimensional printing of patient-specific computed tomography lung phantoms: a reader study
    Shapira, Nadav
    Donovan, Kevin
    Mei, Kai
    Geagan, Michael
    Roshkovan, Leonid
    Gang, Grace J.
    Abed, Mohammed
    Linna, Nathaniel B.
    Cranston, Coulter P.
    O'Leary, Cathal N.
    Dhanaliwala, Ali H.
    Kontos, Despina
    Litt, Harold I.
    Stayman, J. Webster
    Shinohara, Russell T.
    Noel, Peter B.
    PNAS NEXUS, 2023, 2 (03):
  • [4] Comparing the Accuracy of Patient-Specific Guide and Universal Guide for Distal Femoral Osteotomy in Dogs
    Cheon, Jaeeon
    Kang, Jinsu
    Kim, Namsoo
    Heo, Suyoung
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2024,
  • [5] Accuracy of a patient-specific 3D printed drill guide for placement of cervical transpedicular screws
    Hamilton-Bennett, Sinead E.
    Oxley, Bill
    Behr, Sebastien
    VETERINARY SURGERY, 2018, 47 (02) : 236 - 242
  • [6] Three dimensional patient-specific printed cutting guides for closing-wedge distal femoral osteotomy
    JianHui Shi
    Wei Lv
    Yan Wang
    Ben Ma
    Wei Cui
    ZhenZhong Liu
    KeCheng Han
    International Orthopaedics, 2019, 43 : 619 - 624
  • [7] Three dimensional-printed patient-specific cutting guides for femoral varization osteotomy: Do it yourself
    Arnal-Burro, Juan
    Perez-Mananes, Ruben
    Gallo-del-Valle, Eudaldo
    Igualada-Blazquez, Cristina
    Cuervas-Mons, Manuel
    Vaquero-Martin, Javier
    KNEE, 2017, 24 (06): : 1359 - 1368
  • [8] Three dimensional patient-specific printed cutting guides for closing-wedge distal femoral osteotomy
    Shi, JianHui
    Lv, Wei
    Wang, Yan
    Ma, Ben
    Cui, Wei
    Liu, ZhenZhong
    Han, KeCheng
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (03) : 619 - 624
  • [9] Three-dimensional corrective osteotomy using a patient-specific osteotomy guide and bone plate based on a computer simulation system: accuracy analysis in a cadaver study
    Omori, Shinsuke
    Murase, Tsuyoshi
    Kataoka, Toshiyuki
    Kawanishi, Yohei
    Oura, Keiichiro
    Miyake, Junichi
    Tanaka, Hiroyuki
    Yoshikawa, Hideki
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2014, 10 (02): : 196 - 202
  • [10] A three-dimensional printed patient-specific scaphoid replacement: a cadaveric study
    Honigmann, Philipp
    Schumacher, Ralf
    Marek, Romy
    Buttner, Franz
    Thieringer, Florian
    Haefeli, Mathias
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (04) : 407 - 412