Mathematical modelling of groundwater flow at Sellafield, UK

被引:13
|
作者
McKeown, C [1 ]
Haszeldine, RS [1 ]
Couples, GD [1 ]
机构
[1] Univ Glasgow, Glasgow G12 8QQ, Lanark, Scotland
关键词
finite element modelling; groundwater flow; radioactive waste;
D O I
10.1016/S0013-7952(99)00008-3
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Sellafield in West Cumbria was a potential site for the location of the UK's first underground repository for radioactive, intermediate level waste (ILW). The repository was to lie around 650 m beneath the ground surface within rocks of the Borrowdale volcanic group (BVG), a thick suite of SW dipping, fractured, folded and metamorphosed Ordovician meta-andesites and ignimbrites. These are overlain by an onlapping sequence of Carboniferous and Permo-Triassic sediments. In situ borehole measurements showed that upward trending fluid pressure gradients exist in the area of the potential repository site, and that there are three distinct fluid types in the subsurface; fresh, saline and brine (at depth, to the west of the site). Simulations of fluid flow in the Sellafield region were undertaken with a 2D, steady-state, coupled fluid and heat flow simulation code (OILGEN). In both simplified and geologically complex models, topographically driven flow dominated the regional hydrogeology. Fluids trended persistently upwards through the potential repository site. The dense brine to the west of the site promoted upward deflection of topographically driven groundwaters. The inclusion in hydrogeological models of faults and variably saline sub-surface fluids was essential to the accurate reproduction of regional hydraulic head variations. Sensitivity analyses of geological variables showed that the rate of groundwater flow through the potential repository site was dependent upon the hydraulic conductivity of the BVG, and was unaffected by the hydraulic conductivity of other hydrostratigraphic units. Calibration of the model was achieved by matching simulated subsurface pressures to those measured in situ. Simulations performed with BVG hydraulic conductivity 100 times the base case median value provided the "best-fit" comparison between the calculated equivalent freshwater head and that measured in situ, regardless of the hydraulic conductivity of other hydrostratigraphic units. Transient mass transport simulations utilising the hydraulic conductivities of this "best fit" simulation showed that fluids passing through the potential repository site could reach the surface m 15 000 years. Simple safety case implications drawn from the results of the study showed that the measured BVG hydraulic conductivity must be less than 0.03 m year(-1) to be simply declared safe. Recent BVG hydraulic conductivity measurements showed that the maximum BVG hydraulic conductivity is around 1000 times this safety limit. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:231 / 250
页数:20
相关论文
共 50 条
  • [1] Modelling groundwater flow in the Sellafield area
    Heathcote, JA
    Jones, MA
    Herbert, AW
    [J]. QUARTERLY JOURNAL OF ENGINEERING GEOLOGY, 1996, 29 : S59 - S81
  • [2] Coupled modelling of groundwater flow and hydrochemistry in the Sellafield area.
    Littleboy, AK
    Metcalfe, R
    Noy, DJ
    [J]. HIGH LEVEL RADIOACTIVE WASTE MANAGEMENT, 1996 ., 1996, : 135 - 140
  • [3] Hydrogeochemical evidence supporting models for groundwater flow around Sellafield, UK
    Metcalfe, R
    Milodowski, AE
    Noy, DJ
    [J]. USE OF HYDROGEOCHEMICAL INFORMATION IN TESTING GROUNDWATER FLOW MODELS, 1999, : 315 - 328
  • [4] Modelling groundwater flow changes due to thermal effects of radioactive waste disposal at a hypothetical repository site near Sellafield, UK
    A. P. Fraser Harris
    C. I. McDermott
    O. Kolditz
    R. S. Haszeldine
    [J]. Environmental Earth Sciences, 2015, 74 : 1589 - 1602
  • [5] Modelling groundwater flow changes due to thermal effects of radioactive waste disposal at a hypothetical repository site near Sellafield, UK
    Harris, A. P. Fraser
    McDermott, C. I.
    Kolditz, O.
    Haszeldine, R. S.
    [J]. ENVIRONMENTAL EARTH SCIENCES, 2015, 74 (02) : 1589 - 1602
  • [6] Geochemical indicators of deep groundwater movements at Sellafield, UK
    Bath, A
    Richards, H
    Metcalfe, R
    McCartney, R
    Degnan, P
    Littleboy, A
    [J]. JOURNAL OF GEOCHEMICAL EXPLORATION, 2006, 90 (1-2) : 24 - 44
  • [7] Groundwater monitoring - The Sellafield approach
    Eldred, C
    Scarrow, J
    Ambler, M
    Smith, A
    [J]. ADVANCES IN SITE INVESTIGATION PRACTICE, 1996, : 521 - 532
  • [8] Use of uncertainty analysis for chloride in the calibration of groundwater flow models of the Sellafield site
    Bath, AH
    Harding, WG
    Forde, K
    Degnan, PJ
    Norris, S
    Jackson, CP
    Watson, SP
    [J]. USE OF HYDROGEOCHEMICAL INFORMATION IN TESTING GROUNDWATER FLOW MODELS, 1999, : 79 - 91
  • [9] Mechanisms of groundwater flow in the unsaturated zone of the UK Triassic Sandstones - Monitoring and modelling the unsaturated zone
    LaTouche, SVD
    [J]. ENGINEERING GEOLOGY AND THE ENVIRONMENT, VOLS 1-3, 1997, : 1775 - 1779
  • [10] Mathematical modelling of cervical cancer vaccination in the UK
    Choi, Yoon Hong
    Jit, Mark
    [J]. EKC2008: PROCEEDINGS OF THE EU-KOREA CONFERENCE ON SCIENCE AND TECHNOLOGY, 2008, 124 : 405 - 412