摘要
An international collaborative study, involving 16 laboratories, was carried out to calibrate the 1st International Standard Protein S, plasma, for total and free Protein S antigen and for Protein S function. Potency estimates were calculated relative to locally collected fresh normal plasma pools. Estimates of total Protein S antigen showed good agreement between laboratories with inter-laboratory geometric coefficient of variation (gcv%) of 8.8% and a mean value of 0.89 IU/ampoule. Estimates of free Protein S antigen calculated relative to total Protein S antigen in the fresh normal pools were more variable (gcv 26.8%) than estimates calculated relative to free Protein S antigen (gcv 15.3%); the latter comparison was used for calibration with a mean value of 0.89 IU/ampoule. Functional Protein S was estimated using commercial kits which gave an overall mean value of 0.92 IU/ampoule (gcv 14.0%). The Ist International Standard Protein S, plasma, (coded 93/590) was established in October 1995 with a single potency of 0.90 IU/ampoule for all three parameters.
引用
收藏
页码:1237 / 1241
页数:5
相关论文
共 50 条
  • [1] Standardisation of von Willebrand Factor in therapeutic concentrates: Calibration of the 1st International Standard for von Willebrand Factor concentrate (00/514)
    Hubbard, AR
    Sands, D
    Chang, AC
    Mazurier, C
    THROMBOSIS AND HAEMOSTASIS, 2002, 88 (03) : 380 - 386
  • [2] Calibration of the WHO 1st International Standard and SSC/ISTH Secondary Coagulation Standard for Tissue Plasminogen Activator Antigen in Plasma
    Longstaff, C.
    Rigsby, P.
    Whitton, C.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2010, 8 (08) : 1855 - 1857
  • [3] Calibration and commutability assessment of the 1st International Standard for Diphtheria Antitoxin Human
    Stickings, Paul
    Rigsby, Peter
    Coombes, Laura
    von Hunolstein, Christina
    Ralli, Luisa
    Pinto, Antonella
    Sesardic, Dorothea
    BIOLOGICALS, 2013, 41 (06) : 384 - 392
  • [4] Calibration of the WHO 1st International Standard for blood coagulation factor V in plasma, human (03/116)
    Hubbard, A. R.
    Weller, L. J.
    Johnes, S.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2007, 5 (06) : 1318 - 1319
  • [5] A collaborative study to establish the 1st International Standard for factor XIII plasma
    Raut, S.
    Merton, R. E.
    Rigsby, P.
    Muszbek, L.
    Seitz, R.
    Arieans, R. A. S.
    Barrowcliffe, T. W.
    Ichinose, A.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2007, 5 (09) : 1923 - 1929
  • [6] REQUIREMENTS FOR THE 1ST INTERNATIONAL IMAGING STANDARD
    BLUM, C
    HOFMANN, GR
    KROMKER, D
    IEEE COMPUTER GRAPHICS AND APPLICATIONS, 1991, 11 (02) : 61 - 70
  • [7] Preparation and evaluation of the 1st international standard for the quantitation of HIV-2 RNA in plasma
    Holmes, Harvey
    Berry, Neil
    Heath, Alan
    Morris, Clare
    JOURNAL OF VIROLOGICAL METHODS, 2011, 175 (02) : 246 - 252
  • [8] Special issue: 1st International Conference on Security Standardisation Research (SSR 2014)
    Chen, Liqun
    Mitchell, Chris
    INTERNATIONAL JOURNAL OF INFORMATION SECURITY, 2016, 15 (06) : 573 - 574
  • [9] Calibration of BK Virus Nucleic Acid Amplification Testing to the 1st WHO International Standard for BK Virus
    Tan, S.
    Milligan, S.
    Sahoo, M.
    Taylor, N.
    Pinsky, B.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2017, 17 : 290 - 290
  • [10] THE 1ST INTERNATIONAL STANDARD FOR ANTI-MEASLES SERUM
    FORSEY, T
    HEATH, AB
    MINOR, PD
    BIOLOGICALS, 1991, 19 (03) : 237 - 241