DEFLECTION OF CANCELLOUS BONE SCREWS UNDER A CANTILEVER BENDING LOAD

被引:0
|
作者
Vega, Carolina [1 ]
Arshanskiy, Maria [2 ]
Sagar, Amrit [2 ]
Saigal, Anil [2 ]
James, Thomas P. [2 ]
Smith, Eric [3 ]
Cassidy, Charles [3 ]
机构
[1] Tufts Univ, Sch Med, Boston, MA 02111 USA
[2] Tufts Univ, Dept Mech Engn, Medford, MA 02155 USA
[3] Tufts Med Ctr, Boston, MA 02111 USA
关键词
Cantilever; Bending; Cancellous Bone Screw; DESIGN; FEMURS;
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Surgical bone screws can be subjected to cyclic bending loads when plating constructs are used in the fixation of weight bearing members. While extensive research has been conducted on axial loading that leads to screw pull-out, there is a gap in our understanding of how asymmetric bending loads contribute to screw fracture. The focus of this research was to examine the effect of screw length (20 mm and 40 mm) and cancellous bone density (0.48 g/cm(3) and 0.24 g/cm(3)) on the relative stiffness of 6 5 mm cancellous bone screws subjected to a cantilever bending load. It was hypothesized that longer screws in higher density cancellous bone would result in less screw deflection, supporting clinical practice. For testing, synthetic composite bone was used to simulate the characteristics of natural bone while subjecting screws to quasi-static loading with a universal testing machine. Contrary to the hypothesis, neither screw length nor cancellous bone density resulted in a statistically significant difference (p > 0.05) in deflection for loading up 450 N. The cortical shelf appeared to support the majority of the bending load through compression, rather than acting as a fulcrum. When the 3.0 mm cortex was removed, there was a significant difference in deflection due to both screw length and cancellous bone density.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Modeling Bicortical Screws Under a Cantilever Bending Load
    James, Thomas P.
    Andrade, Brendan A.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (12):
  • [2] The deflection of a cantilever bar rotated under end load.
    Hunter, W
    [J]. PROCEEDINGS OF THE CAMBRIDGE PHILOSOPHICAL SOCIETY, 1933, 29 : 423 - 439
  • [3] LARGE DEFLECTION OF CANTILEVER BEAMS IN BENDING
    MITELMAN, M
    [J]. ISRAEL JOURNAL OF TECHNOLOGY, 1968, 6 (03): : 227 - &
  • [4] Micro-cantilever bending for elastic modulus measurements of a single trabecula in cancellous bone
    Yamada, Satoshi
    Tadano, Shigeru
    Fukasawa, Koichi
    [J]. JOURNAL OF BIOMECHANICS, 2016, 49 (16) : 4124 - 4127
  • [5] Cancellous Screws Are Biomechanically Superior to Cortical Screws in Metaphyseal Bone
    Wang, Tim
    Boone, Christopher
    Behn, Anthony W.
    Ledesma, Justin B.
    Bishop, Julius A.
    [J]. ORTHOPEDICS, 2016, 39 (05) : E828 - E832
  • [6] The Approximate Solutions of Large Deflection of a Cantilever Beam under a Point Load
    Meng, Baochen
    Lian, Chencheng
    Zhang, Jun
    Jing, Huimin
    Wu, Rongxing
    Wang, Ji
    [J]. Mathematical Problems in Engineering, 2023, 2023
  • [7] Large deflection of constant curvature cantilever beam under follower load
    Nallathambi, Ashok Kumar
    Rao, C. Lakshmana
    Srinivasan, Sivakumar M.
    [J]. INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2010, 52 (03) : 440 - 445
  • [8] Bioactive ceramic coating of cancellous screws improves the osseointegration in the cancellous bone
    Lee, Jae Hyup
    Nam, Hwa
    Ryu, Hyun-Seung
    Seo, Jun-Hyuk
    Chang, Bong-Soon
    Lee, Choon-Ki
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2011, 16 (03) : 291 - 297
  • [9] Elastoplastic Analysis of a Cantilever Beam under Combined Compressive and Bending Load
    Boix Salazar, Julio A.
    de lange, Dirk F.
    Torres Cruz, Alberto
    Medellin Castillo, Hugo I.
    Mejia Rodriguez, Gilberto
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 9, 2014,
  • [10] Large deflection of a cantilever nano-beam under a vertical end load
    Chen, Ming
    [J]. ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING, PTS 1-4, 2013, 353-356 : 3387 - 3390